ZKaccess TF1700 Manuale utente

Installation Guide
ZKAccess.com
TF1700
Standalone Outdoor Fingerprint Reader Controller
&
ZKAccess |Classic software 3.5

2
TF1700 &ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE
What’s in the Box
DiodeZKAccess Software
TF1700
4 Large Screws & Anchors,
2 Small screws
Screwdriver
ZKAccess Security Management Software
TF1700
Stick this mounting paper to the wall
or door frame. Drill the holes according
to the mounting paper.
Installation Template Back PlateRubber Gasket
AC Power Adapter USB Cable AdaptorNetwork Cable Cables

3
TF1700 &ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE
CONTENT
What’s in the Box....................................................................2
Optional accessories............................................................4
Safety Precautions..................................................................5
Product PIN Diagram...........................................................6
Product Dimension...............................................................8
Cables and Connectors .....................................................9
Mounting the reader on the wall............................10
Power Connection.............................................................11
RS485 Connection..............................................................12
PC Connection ......................................................................... 12
FR1200 Connection ................................................................ 13
Lock Relay Connection ...................................................14
Normall Open Lock................................................................. 14
Normall Close Lock ................................................................. 15
Aux. Input Connection....................................................16
Exit Button Connection ......................................................... 16
Aux. Output Connection...............................................17
Alrm Button Connection....................................................... 17
Door Bell Button Connection............................................... 18
Weigand Input Connection ........................................19
RFID Button Connection ....................................................... 19
Weigand Output Connection....................................20
Access Control Panel .............................................................. 20
Standalone Installation ...................................................21
FR1200 Connection ................................................................ 21
Installation with Third Party Panels.........................22
C3 Conroller Panel Connection ........................................... 22
inBIO Conroller Panel Connection...................................... 23
How Does TF1700 work.................................................24
Troubleshooting ..................................................................25
How to Place a Finger on Scanner ......................... 26
Electrical Specifications .................................................28
Specifications ........................................................................29
ZKAccess |CLASSIC 3.5
Software Installation and Setup
starts at page 30

4
TF1700 &ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE
Optional accessories
Wiegand Card Reader
FR1200 FP Reader
Prox Card
K1-1 Exit Button

5
TF1700 &ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE
Safety Precautions
The following precautions are to keep user’s safe and prevent any damage.
Please read carefully before installation
Do not install the device in a place subject to direct sun
light, humidity, dust or soot
Do not place a magnet near the product. Magnetic objects
such as magnet, CRT, TV, monitor or speaker may damage
the device.
Do not place the device next to heating equipment
Be careful not to let liquid like water, drinks or chemicals
leak inside the device.
Do not let children touch the device without supervision
Do not drop or damage the device
Do not disassemble, repair or alter the device.
Do not use the device for any other purpose than specied.
Clean the device often to remove dust on it. In cleaning, do
not splash water on the device but wipe it out with smooth
cloth or towel.
Contact your supplier in case of a problem.

6
TF1700 &ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE
Reset
Product PIN Diagram
OLED
Display
USB Host
Reset Switch
3x5 Keypad
Door Bell &
LED Indicator
Area
ZK Optical
Sensor
Star-shaped screw hole for xing reader to the back plate

SN 000000000000
Purple
Brown
White
Black
Gray
Blue
Red
Yellow
Orange
Green
:
:
:
:
+12V
GND
IWD1
IWD0
RLED
GLED
BEEP
WD0
WD1
GND
485+
485-
+12V
GND
Red
Black
White
Green
Blue
Gray
Purple
Green
White
Black
Blue
Yellow
Red
Black
BELL-
BELL+
SEN
GND
BUT
NO1
COM1
YNC1
NO2
COM2
RJ45-1
RJ45-2
RJ45-3
RJ45-6
Bell LOCK Alarm Ethernet
Power485WG-OutReader
Fingerprint Access Control
Manufacturing license No: 75569364-2
SBTS Registered No: H0201
Power Supply DC 12V == 3A
Operating EnvironmentTemperature: 0ºC-45ºC
ISO9000 : 2008 CE FC RoHS
69370226
Purple
Brown
White
Black
Gray
Blue
Red
Yellow
Orange
Green
:
:
:
:
+12V
GND
IWD1
IWD0
RLED
GLED
BEEP
WD0
WD1
GND
485+
485-
+12V
GND
Red
Black
White
Green
Blue
Gray
Purple
Green
White
Black
Blue
Yellow
Red
Black
BELL-
BELL+
SEN
GND
BUT
NO1
COM1
YNC1
NO2
COM2
RJ45-1
RJ45-2
RJ45-3
RJ45-6
Bell LOCK Alarm Ethernet
Power485WG-OutReader
Fingerprint Access Control
Manufacturing license No: 75569364-2
SBTS Registered No: H0201
Power Supply DC 12V == 3A
Operating Environment Temperature: 0ºC-45ºC
ISO9000 :
2008 CE FC RoHS
69370226
7
TF1700 &ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE
7 pin Cable connectors
5 pin Cable connectors
5 pin Cable connectors
5 pin Cable connectors
2 pin Cable connectors
RJ 45
1
2
3
4
5
6
7
8
Ethernet

Reset
8
TF1700 &ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE
2.46in
(62.5mm) 2in
(51mm)
1.63in
(41.5mm)
7.28in
(185mm)
6.125in
(153mm)
Product Dimension

9
TF1700 &ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE
Cables and Connectors
1
7
PIN DESCRIPTION WIRE
1 +12V Red
2 GND Black
3 IWD1 White
4 IWD0 Green
5 RLED Blue
6 GLED Gray
7 BEEP Purple
PIN DESCRIPTION WIRE
1 BELL- Purple
2 BELL+ Brown
3 SEN White
4 GND Black
5 BUT Gray
PIN DESCRIPTION WIRE
1 NO1 Blue
2 COM1 Red
3 NC1 Yellow
4 NO2 Orange
5 COM2 Green
PIN DESCRIPTION WIRE
1 WD0 Red
2 WD1 White
3 GND Black
4 485+ Blue
5 485- Yellow
1
5
1
5
1
5
PIN DESCRIPTION WIRE
1 12V DC Red
2 GND Black • Power In
1
2
RJ 45
1
2
3
4
5
6
7
8
PIN DESCRIPTION WIRE
1 RJ45-1 Yellow
2 RJ45-2 Green
3 RJ45-3 Red
4 RJ45-6 Black
• TCP/IP

10
TF1700 &ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE
Mounting the reader on the wall
Fix back plate to the wall using wall mounting screws
TF1700
Stick this mounting paper to the wall
or door frame. Drill the holes according
to the mounting paper.
We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam
cannot be found, then use the supplied drywall plastic mollies (anchors).
1. Stick the mounting
template on the wall
and make holes as
per the markings.
2. Mount the rubber gasket
and the back plate on the
wall with the help of the
supplied screws.
Reset
Reset
4. Use star-shaped screw to mount it3. Inserting Reader to backplate
1
2
Altri manuali per TF1700
1
Indice
Altri manuali ZKaccess Controllori