ZoneVu ZSI-330 Manuale utente

ZSI-330 User Manual Issue 01 Page 1 of 30
USER MANUAL
ZSI-330
ZSI-330
CCTV ISDN Controller
Issue 01
ZSI-330
MEYERTECH LIMITED

ZSI-330 User Manual Issue 01 Page 2 of 30
Contents
Contents............................................................................................................................................................................2
Introduction ......................................................................................................................................................................3
What is a ZSI-330?.......................................................................................................................................................3
Operation..........................................................................................................................................................................4
Features.............................................................................................................................................................................6
Camera switching .........................................................................................................................................................6
Alarm handling.............................................................................................................................................................6
Auxiliary Outputs.........................................................................................................................................................6
EFD support..................................................................................................................................................................6
Security.........................................................................................................................................................................6
I/O Operation................................................................................................................................................................6
OSD..............................................................................................................................................................................7
Configuration....................................................................................................................................................................8
Config Version .............................................................................................................................................................8
ZoneVu Port .................................................................................................................................................................9
Telemetry....................................................................................................................................................................10
Basic Dialup ...............................................................................................................................................................12
Advanced Dialup........................................................................................................................................................13
Telephone...................................................................................................................................................................14
Display........................................................................................................................................................................15
Camera Captions.........................................................................................................................................................16
Sequences...................................................................................................................................................................17
Alarms ........................................................................................................................................................................18
Alarm Contacts...........................................................................................................................................................19
Alarm Contact Events.................................................................................................................................................20
Receiver Alarm Events...............................................................................................................................................22
Video Loss Events......................................................................................................................................................23
Video Loss Setup........................................................................................................................................................24
Enables .......................................................................................................................................................................25
LEDs...........................................................................................................................................................................26
Commands..................................................................................................................................................................26
Support ...........................................................................................................................................................................27
Maintenance ...................................................................................................................................................................27
Returns Procedure ......................................................................................................................................................27
Disposal..........................................................................................................................................................................28
Warranty.........................................................................................................................................................................29
MEYERTECH LIMITED
ZSI-330

ZSI-330 User Manual Issue 01 Page 3 of 30
Introduction
ISDN connection
Intersite communications
Video transmission
System backup
64K or 128K ISDN operation
Local operator
Support of Meyertech 3rd Party EFDs
.
KEY FEATURES
Thank you for purchasing Meyertech’s ZSI-330.
Please read this user guide prior to using
this product. It will help you to achieve the maximum
benefit from the product. The manual covers
installation, operation and maintenance of a ZSI-330.
What is a ZSI-330?
A ZSI-330 is part of the ZoneVu Site Controller family. It
allows the interconnection of remote sites via an ISDN line.
The unit operates as a transmitter.
Combined with other members of the Meyertech site controller
family, an operator can seamlessly control cameras
located throughout the country.
When combined with other elements of Meyertech’s Site
Controller family, a unit can, under alarm conditions,
automatically contact a remote control room or can be part
of a seamless dial on demand service.
The features described in this manual refer to :
Version 1.2.0.0 of the ZSI-330 firmware
The information in this manual is believed to be accurate and reliable. However,
Meyertech Limited assumes no responsibility or liability for its use, or for any
infringement of patents or other rights of third parties, which may result from its
use. No license is granted by implication or otherwise under any patent or other
rights of Meyertech. All specifications are subject to change without prior notice.
MEYERTECH LIMITED are committed to continuous product development and
therefore reserve the right to change
specifications without notice.
©2004 ALL RIGHTS RESERVED.
ZSI-330
MEYERTECH LIMITED

ZSI-330 User Manual Issue 01 Page 4 of 30
Operation
MEYERTECH LIMITED
OFFICE BLOCK ONE
SOUTHLINK BUSINESS PARK
OLDHAM OL4 1DE
TEL: +44 (0) 161 628 8406
email suppor[email protected]
DRWG No:
PROJECT:
TITLE:
SCALE:
MEYERTECH LTD
ZSI-330 Installation
CLIENT:
NTS
ISS. DRN. CHKD. NOTES
01 MDW NONE NO PART OF THIS DOCUMENT
MAY BE REPRODUCED OR
DISTRIBUTED IN ANY FORM
WITHOUT PRIOR WRITTEN
CONSENT FROM MEYERTECH
LIMITED.
COPYRIGHT 2002
ALL RIGHTS RESERVED
11-05-04
DATE
ZVK-77
RS422
RS232
RS485
VIDEO
LAN
RS422
RS422/485
1. Local operator
2. Export only over ISDN
3. Shared monitor output
ZSI-330
ZoneVu
ISDN
MONITOR
x 16
3rd party domes
PT heads
MEYERTECH LIMITED
OFFICE BLOCK ONE
SOUTHLINK BUSINESS PARK
OLDHAM OL4 1DE
TEL: +44 (0) 161 628 8406
email suppor[email protected]k
DRWG No:
PROJECT:
TITLE:
SCALE:
MEYERTECH LTD
ZSI-330 Installation
CLIENT:
NTS
ISS. DRN. CHKD. NOTES
01 MDW NONE NO PART OF THIS DOCUMENT
MAY BE REPRODUCED OR
DISTRIBUTED IN ANY FORM
WITHOUT PRIOR WRITTEN
CONSENT FROM MEYERTECH
LIMITED.
COPYRIGHT 2002
ALL RIGHTS RESERVED
DATE
RS422
RS232
RS485
VIDEO
LAN
1. Export only over ISDN
ISDN
11-05-04
ZSI-330
ZoneVu RS422/485 x 16
3rd party domes
PT heads
MEYERTECH LIMITED
ZSI-330

ZSI-330 User Manual Issue 01 Page 5 of 30
Installation
See ZSI-330 Installation Guide – available from Meyertech Technical Support
MEYERTECH LIMITED
ZSI-330

ZSI-330 User Manual Issue 01 Page 6 of 30
Features
Camera switching
The ZSI-330 supports 16 video inputs and 1 video output. The video output is shared between a single local
operator (if present) and the remote operator.
The ZSI-330 can be configured to run a sequence.
Alarm handling
The ZSI-330 supports local alarm events which can be used trigger a range of functions:
• Dialling a remote control room – to report the alarm remotely
• Reporting the alarm to a keyboard – to report the alarm locally
• Energising a local relay
• Sending a local camera to a preset
It can take as an alarm source either its own contact alarm inputs or alarm inputs via a ZoneVu receiver (or
supported 3rd party dome – see ZSI-EFD support document).
Auxiliary Outputs
The ZSI-330 supports auxiliary relay outputs which can be mapped to a range of ZoneVu commands. They
can also be controlled via alarm events.
EFD support
The ZSI-330 supports Meyertech extensive range of 3rd party EFDs (embedded firmware drivers) on the
ZVR port. Contact Meyertech Sales for details of EFD support.
Security
The ZSI-330 supports a PIN code which prevents access to the site by all but authorised equipment.
I/O Operation
Relay Function
The ZoneVu function used to control the specified relay
Contact Inputs
The trigger state of the contact inputs – normally open or normally closed.
MEYERTECH LIMITED
ZSI-330

ZSI-330 User Manual Issue 01 Page 7 of 30
OSD Static caption
A static caption can be set up for each of the 16 video inputs.
Alarm caption
An alarm caption can be set up for each of the 16 alarm contacts.
MEYERTECH LIMITED
ZSI-330

ZSI-330 User Manual Issue 01 Page 8 of 30
Configuration
Configuration of the ZSI-330 is done through the RS232 port using Meyertech’s Windows based
configuration tool Mpower.
The ZSI-330 detects when a lead is attached to the RS232 port using the MODE pins, and enters
configuration mode.
In configuration mode, the CPU LED flashes at a faster rate and the ZoneVu port is disabled.
Config Version
This entry screen shows information relating to the firmware installed in the ZSI-330
Config structure
The version number of the configuration data format within the attached ZSI-330. – see Mpower manual for more
details.
(stored)
The version number of the configuration data format stored on the PC. – see Mpower manual for more details.
Software
ZSI-330
The version number of the ZSI-330’s firmware
Status
The status of the communications – see Mpower manual for more details
MEYERTECH LIMITED

ZSI-330 User Manual Issue 01 Page 9 of 30
ZoneVu Port
MAC address
The address that this unit will respond to when polled by a site controller.
Only used when polling mode is set to slave Default = 1
Terminate
When enabled a 120Ohm termination resistor is used on the receive input. This should be enabled unless the unit is one
of many connected to a site controller, and not the last in the chain.
Default = Off
Polling mode
Sets the mode of communication used on this port. Set to Master if a keyboard is connected, or Slave if connected to
site controller. Point-to-point mode disables polling. Note Slave mode is not currently available.
Default = Master
Baud rate
ZSI-330
Sets the communication speed for this port. Must match all other connected equipment on this port. Available speeds:
1200, 2400, 4800, 9600, 19200, 38400, 57600, 12800.
Default = 9600
Connection
Select the communication method from 2-wire half duplex or 4-wire full duplex RS485
Default = 4-wire
MEYERTECH LIMITED

ZSI-330 User Manual Issue 01 Page 10 of 30
Telemetry
Receiver
For each receiver 1 – 16 the telemetry can be setup as follows
Port
Select the port used to transmit telemetry. ZVR port would normally be used unless the receivers are connected
through a separate site controller. ZoneVu port is used to route telemetry through the site controller (not
currently supported). Default = ZVR
Polled
Tick this box if the receiver is to be polled for alarm and status information, where supported
Default = Off
ZVR port
Settings for all receivers connected on the ZVR port
Baud rate
ZSI-330
Sets the communication speed for the receivers. Available speeds: 1200, 2400, 4800, 9600, 19200, 38400,
57600, 12800. Default = 9600
MEYERTECH LIMITED