Zoox LEVIATHAN 5000 Manuale utente

User Manual
Leviathan 5000

1
Attached are the warning level with different situation.
Read carefully to keep the best performance and saftly
SAFETY GUIDE
Contents that it is assumed that the possibility of death
or serious injury is imminent
Contents that it is assumed that the possibility of death
or serious injury is imminent
ATTENTION
WARNING
WARNING
DANGER
Contents thatthe possibility that a person will suffer
damage,or a content that may cause property damage
FORBID MUST UNPLUG THE POWER
HANDLING OF POWER PLUG , POWER CORD &SOCKET
ATTENTION GRADE
MARK
Thanks for choosing Leviathan intelligent Wave pump.
Please read the user manual clearly before use.
Use the correct ballast come with
the Leviathan and make sure the
spec. is suitable. Use others ballast
may caused the pump break or the
ballast burn. You can contact the
distributor or the shop to replace /
buy the ballast if the ballast broke.
Do not bend, pull, twist, twist, put
heavy things on, pinch, or process
the power cord or the ballast. It may
caused to damage the power cord
and cause a fire or electric shock.
Do not connect or disconnect the
power with wet hands. It may cause
an electric shock.
FORBID
FORBID
MUST MUST
MUST
Do not bend, pull, twist, twist, put
heavy things on, pinch, or process
the power cord or the ballast. It may
caused to damage the power cord
and cause a fire or electric shock.
Always have a drip loop on the
power cord. Do not allow water
droplets to travel through the cord
and come in contact with the outlet
as it may cause a fire or electric
shock.
DRIP LOOP

2
WARNING
ATTENTION
ATTENTION
WHILE OPERATION
SAFETY GUIDE
INSTALLATION
WARNING
HANDLING OF POWER PLUG , POWER CORD & SOCKET
Unplugging the power during
maintenance.
It may cause an electric shock.
Dust on ballast needed to be cleaned
regularly. Accumulated dust may
cause fire due to moisture. Please
wipe off with a dry cloth.
Do not install in places that get hot
(closed fire, heat appliances, under
the sun, etc.) or exposed to direct
sunlight It can only be used indoors
below 35 ° C.
Do not install in places where the
power cord or ballast get wet. There
is a possibility of electric shock and
leakage.
WARNING
Be careful when handling, carrying,
setting, etc. not to give an impact to
this product. Impact may cause
damage or failure.
Do not use or placed at outdoors. It
may cause overheat, explosion, etc.
Do not install that may close to
children. It may cause danger to
children.
When abnormal (such as burnt odor),
immediately unplug the power and
stop using it. It may cause overheat
or fire. Please contact the retailer you
purchased or us.
Do not modify or process this
product. It may cause damage or
injury.
Do not operate when the pump can
not circulate water and the pump is
not filled with water. It may cause
damage or fire.
Do not use for any purpose other
than recommended. It may cause an
unexpected accident or danger.

3
ATTENTION
●Before Use
●Package contents / Name of each part
.Compensation for the live stock is not performed by stopping the pump.
.This product only use inside water.
External Magnet Interior Magnet
Rotor Pump case
Pump Body
Intelligent Controller
Power cable Ballast Connection cable
Cable Holder Screws for Controller placement Protection Sponge
·Make sure that the pump does not run idle due to a drop in water level, etc.
·Please be careful that sand and foreign matter are not sucked into the body.
This can cause serious damage.Also, the warranty does not apply in this case.
· Do not use in corrosive or abrasive liquids.
· When holding the pump, do not lift the pump by the cord.
· Clean it regularly to avoid the adhesion of lime algae,calcium components,
and moss.
· Connecting the ballast to the controller before connected to the socket.
· Do not use any adapter other than we provided.

4
●INSTALLATION
1. Please clean the glass which you plan to place the external magnet.
2. Place the pump in correct place and slide the external magnet
close to the internal magnet.(see ref. at Right)
3. You can take out the rotor / pump body without remove the magnet.
4. Remove the cover of connector attached on controller and connect to the pump.
You can use the extend cable if necessary.
Do not direct attach the magnet together and it might cause injury and demage of the glass.
The placement of pump too close to the corner of glass might cause noise / sound reflection.
※
※
キャップ
Model
Leviathan 5000
●Specification
80 ㎜74 ㎜
95 ㎜15 ㎜
Max.Glassthickness20mm
FLOW RATE
SUITABLE FOR AQUARIUM
MAX. POWER CONSUMPTION
GLASS THICKNESS
50∼20,000 L /h
150∼2,200L
24W(±5%)
0.4W(±5%)
Max. 20mm
MIN. POWER CONSUMPTION
Do not turn on the power when the pump is not
setting up correctly inside the water.

5
●Cable & Controller placement
●FLOW DIRECTION ADJUSTMENT
5.CONNECTION GRAPH
①Cable arrangement
②Controller Placement
Use the cable holder to fix the cable as your wish.
You can fix the controller with built in fix plate.
Remove the fix plate from the back of the controller.
Screw to fix the plate to the right position.
REMOVABLE
Make sure the direction is correct
CONTROLLER
POWER CORD
BALLAST
ADJUSTABLE
PUMP
ATTENTION
FOR SAFTLY USE THIS PRODUCT , PLEASE CONNECT EACH PARTS IN THE CORRECT WAY FROM
ABOVE PICTURE.
MAKE SURE TO SETTING UP DRILL LOOP IN EACH WIRE AND LOCK THE CONNECTOR FIRMLY.
THE PUMP WILL AUTOMATIC TURN ON IN MIN. POWER(5%) WHEN YOU CONNECTED ALL PARTS
AND THE POWER CORRECTLY.

6
RETURN TO HOME PAGE
Entry:Current Wave schedule.(Details please check “Wave schedule setting”)
Number:Current link up pumps.
Mode:Current mode of wave setting.
Time:Current wave setting operate time period.
Week:Current wave setting operate days in a week.
Speed:Current Speed (RPM) of the pump.
Power:Current power consumption of the pump.
Wave ICON( ):
Setting wave schedule and details.
Setting ICON( ):
Advanced setting of pump and controller.
N:Current connection status.
※If left unattended for a while, the power consumption
and the speed(RPM) will be displayed on the standby screen.
.Press any button to return to the home screen.
RETURN TO LAST PAGE
●HOME
●RETURN
●CONTROLLER INTRODUCTION
●HOME SCREEN
※N = Normal Mode.(No connection with other Leviathan pumps / Standalone operation)
※M = Master Mode.(Master unit of connection with other Leviathan pumps)
※S = Slave Mode.(Master unit of connection with other Leviathan pumps)

7
Setting up Wave schedule by different mode , time period and days.
You can setting up to 16 schedule per day.
Press the dial, Wave1, Wave2, Wave3....
and the Wave settings are displayed.
(e.g.WAVE1 is working on the left picture. )
Turn on this schedule with ON /OFF.
Status:
(Status , Mode , Time and Save will display at the screen)
1. Click on Wave ICON ( )
2.
Turn the dial to WAVE1 and press the dial to enter the setting screen.
●WAVE SCHEDULE SETTING

8
Mode:
Pumps are working with constant flow.
tnatsnoC
Simulation of strong wave like a rough sea.
Rough Sea
Tide
You can choose the wave mode.
There are 4 pre set Mode :Constant
, Rough sea , Tide ,Random.
And Customs allows to fully setting
up all details by advanced aquarist.
All settings are allowed to setup
details separately.
When you select Rough Sea, you will see the
screen on the left.
You can set the following items on this screen:
Max Speed: Maximum wave power
Min Speed: Wave minimum power
Wave length: You can set the wave intensity
interval. The shorter the speed, the more gradual
the wave strength changes.
Simulation of tide
, gradually changes strength.
When you select Tide, you will see the screen on
the left.
You can set the following items on this screen:
Max. Speed: Maximum wave power
Min. Speed: Minimum wave power
Wave length: You can set the gap between the
strength of the wave. The shorter the speed, the
more gradual the wave strength changes.
When you select constant, you will see the left
screen, and you can set the power of the flow with
Max. speed.
The graph below shows the pump's power, the
horizontal axis is the elapsed time, and the
operation of the pumps being set.

9
【Luminous Dial Ring 】
The Dial Ring will illuminous the color of your current wave pattern.
The gap between the strength and the wave
becomes a random wave.
Random
Fully custom wave pattern for advanced aquarist
。
Custom
Each wave schedule is available to setting up
operate time period and day.
※To keeping the Leviathan operate all day ,make sure to set up schedule from 00:00 ~ 23:59.
Please do not set up the time period from 00:00 ~ 00:00, it will have no response to your setting.
Time:
If you select Random, the left screen will be
displayed.
You can set the following items on this screen.
Max Speed: Maximum wave power
Min Speed: Minimum wave power
If you select Random, the left screen will be
displayed.
You can set the following items on this screen.
Max Speed: Maximum wave power
Min Speed: Minimum wave power
Rise Time: You can set the interval between the
minimum and maximum times of the wave.
Fall time: Allows you to set the distance
between the waves from the maximum time to the
minimum time.
Constant (Green) , Rough Sea (Blue) , Tide (Pink) ,Random (Orange),Custom(Purple)
When you select time, you will see the screen in
the right picture.
Weekday: You can set the day of the week that
the Wave schedule you are setting up currently.
Time range: Allows you to set the time period of
the wave schedule you are setting up currently.
Indice
Altri manuali Zoox Pompa dell'acqua
Manuali Pompa dell'acqua popolari di altre marche

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guida alla risoluzione dei problemi

DUROMAX
DUROMAX XP WX Series Manuale utente

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuale utente

Franklin Electric
Franklin Electric IPS Manuale utente

Xylem
Xylem e-1532 Series Manuale utente

Milton Roy
Milton Roy PRIMEROYAL Manuale utente