ABB TruFit Manuale utente

—
94-1100-00002874 A0
USER MANUAL
TruFit™ Power Distribution Unit
50-300 kVA
The ABB TruFit™ PDU offers the most
reliable and flexible power distribution
product on the market today with
almost unlimited configurations of
panelboards and sub-feed breakers to
meet every load requirement. One
cabinet design supports ratings up to
300kVA.
For a comprehensive overview of
publications available for the ABB
TruFit™ PDU product line, refer to the
inside cover of this publication. Web
link and QR code references are also
included.

2 94-1100-00002874 A0 EN│TruFit™ Power Distribution Unit
—
The Company
We are an established world force in the design and manufacture of power electronics and power
protection equipment.
As a part of ABB, a world leader in electrical technology, we offer customers application expertise, service
and support worldwide. We are committed to teamwork, high quality manufacturing, advanced technology
and unrivalled service and support.
The quality, accuracy and performance ABB’s products result from over 100 years of experience,
combined with a continuous program of innovative design and development to incorporate the latest
technology.
—
Quality control
To ensure that we meet our responsibilities and obligations to our customers, our people, our partners,
our suppliers and to our shareholders, we are committed to deliver on-time and on-quality products,
systems and services that meet or exceed our customers’ expectations.
—
For more information
Further publications for the TruFit™ Power Distribution Unit and accessories are available for download
from http://new.abb.com/ups/power-distribution or by scanning the QR code below.

TruFit™
Power Distribution Unit│94-1100-00002874 A0 EN 3
—
Contacting ABB for support
To contact ABB for general information call 800-238-5000 or preventative and remedial services in the
United States, call 800-292-3739. ABB offers a complete range of start-up services, repair services,
preventive maintenance plans and service contracts.
For repair or maintenance service outside the 48 contiguous United States, contact ABB, if available in
your area.
Please provide the following information for customer service when you contact the ABB service center:
Equipment
Part number
Serial number
Voltage rating
Current rating
Purchase date
Installation date
Location
To get important information on all equipment warranties, please contact the ABB service center or
request service follow-up or by scanning the QR code below.

4 94-1100-00002874 A0 EN│TruFit™ Power Distribution Unit
1 Important safety instructions
1.1 Using this manual
TruFit™ Power Distribution Unit, henceforth referred as PDU, is a high-energy device. The following safety
instructions must be observed when working with the device. Refer to the unit’s nameplate for the specific
model designation and operating parameters.
This manual is provided to aid the user in the installation, operation, and maintenance of the PDU,
manufactured by ABB. Read and understand the procedures described to ensure trouble-free installation
and operation. Read through each procedure before beginning the procedure. Perform only those
procedures that apply to the PDU cabinet being installed or operated.
Read all safety and operating instructions before
operating the PDU. Adhere to all warnings on the unit
and in this manual.
1.1.1 List of symbols
These symbols may appear on your PDU or on labels inside the PDU. Most international safety agents
accept them. Everyone in your organization who works with your system should understand the meaning
of these symbols:
SAFETY ALERT SYMBOL
This is the safety alert symbol. It is used to alert you to
potential physical injury hazards. Obey all safety messages
that follow this symbol to avoid possible injury or death.
DANGER
Indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
NOTICE
Is used to address situations not related to physical injury but
could result in property damage.
ELECTRICAL HAZARD SYMBOL
Indicates the presence of an electrical hazard.

TruFit™
Power Distribution Unit│94-1100-00002874 A0 EN 5
ARC FLASH HAZARD SYMBOL
Indicates the presence of an arc flash hazard.
IMPORTANT INFORMATION SYMBOL
This symbol indicates operator tips and/or important
information for the use of the product. This symbol is not used
to indicate information regarding potential hazards or property
damage.
RECYCLE SYMBOL
DO NOT DISCARD SYMBOL
Indicates that you should not discard waste electrical or
electronic equipment (WEEE) in the trash. For proper disposal,
contact your local recycling/reuse or hazardous waste center.
1.2 Safety rules
Save these instructions!
The power distribution unit operates with high currents and voltages. The properly installed system is
grounded to earth and IP 20 rated against electrical shock and foreign objects when all dead fronts are in
place. Installation and service must be performed by a manufacturer’s qualified technicians or a certified
service partner.
General
- Move the PDU in an upright position in its original package to the final destination room.
To lift the cabinets, use a forklift or lifting belts with spreader bars.
- Check for sufficient floor and elevator loading capacity.
- Check the integrity of the PDU equipment carefully.
If you notice visible damage, do not install or start the PDU.
Contact your ABB Service Center immediately.
- WARNING! RISK OF ELECTRICAL SHOCK!
Do not remove covers, there are no user serviceable parts inside.
This should be performed by qualified service personnel.
- This PDU contains potentially hazardous voltages.
- End user must follow applicable regional occupational safety codes/regulations during installation,
operation and equipment maintenance. This may require additional field marking or labelling defining
appropriate level of PPE (Personal Protection Equipment) to reduce the risk of Arc-flash related injuries.
Contact our ABB Service Center for product specific information.

6 94-1100-00002874 A0 EN│TruFit™ Power Distribution Unit
Installation
- This PDU must be installed and connected only by trained personnel.
- Verify accurately during Commissioning and Maintenance of the PDU, for the following:
Damaged components, squeezed wires and cables, or not correctly inserted plugs.
- After removing the sidewalls of the PDU, make sure that all earth connections when reassembling, are
correctly reattached.
- This PDU is intended for use in a controlled indoor environment free of conductive contaminants and
protected against animal intrusion.
- WARNING! HIGH LEAKAGE CURRENT TO GROUND:
Ground connection is essential before connecting to AC input!
- Switching OFF the Unit does not isolate the PDU from the Utility.
- Do not install the PDU in an excessively humid environment or near water.
- Avoid spilling liquids on or dropping any foreign object into the PDU.
- The Unit must be placed in a sufficiently ventilated area; the ambient temperature should not exceed
104F (40°C).
- It is important that air can move freely around and through the Unit. Do not block the air vents.
- Avoid locations in direct sunlight or near heat sources.
Storage
- Store the PDU in a dry location; storage temperature must be within -13°F (-25°C) to 131°F (+55C).

TruFit™
Power Distribution Unit│94-1100-00002874 A0 EN 7
1.3 Safety precautions
The PDU contains hazardous voltages, and hazardous voltages are present regardless of the mode of
operation. Before making any connection(s) to the PDU, ensure that any/all power sources are de-
energized and locked out.
As lethal voltages are present within the PDU during all modes of operation, maintenance shall only be
performed by authorized service personnel.
ABB neither recommends nor knowingly sells this product for use with life support applications or other
FDA designed critical applications.
All wiring should be performed by qualified electricians and in the accordance with local and national
electrical safety codes. Before placing the unit into service, a thorough inspection and supervised start-up
should be performed by a qualified service technician.
This PDU is designed for operation from a three (3) phase, three (3) wire power source. Refer to the
unit’s nameplate for the specific model designation, operating voltage, and input power configuration.
Input over-current protection is to be supplied by the user in accordance with nameplate ratings, in
applications where the PDU has no main breaker.
1.4 Safety considerations
The TruFit™ PDU is designed for commercial applications and should be handled with appropriate care,
following these guidelines:
Keep surroundings clean and free from excess moisture.
Do not operate the PDU system close to gas or electric heat sources.
The system is not intended for outdoor use.
The operating environment should be maintained within the parameters stated in the manual.
Keep the cabinet doors closed and locked to ensure proper cooling airflow and to protect personnel
from dangerous voltages inside the unit.
Only authorized service personnel should perform maintenance on or service
the PDU system.
If service or routine maintenance is required:
Ensure all power is disconnected before performing maintenance.
Ensure the area around the PDU is clean and uncluttered.
Observe all DANGER, CAUTION and WARNING notices affixed to the inside and outside of the
equipment.
To provide sufficient isolation protection when working upstream of the PDU,
open the respective source feeder breakers contained within the PDU.
Prescribing to this maintenance method reduces the risk of electric shock
due to backfeed.

8 94-1100-00002874 A0 EN│TruFit™ Power Distribution Unit
—
Table of contents
1 Important safety instructions ..................................................................................................... 4
1.1 Using this manual .............................................................................................................. 4
1.1.1 List of symbols ............................................................................................................ 4
1.2 Safety rules ....................................................................................................................... 5
1.3 Safety precautions ............................................................................................................. 7
1.4 Safety considerations ......................................................................................................... 7
2 General ................................................................................................................................. 12
2.1 Cybersecurity .................................................................................................................. 12
2.1.1 Disclaimer ................................................................................................................. 12
2.1.2 Ports used by this product ........................................................................................... 12
3 Startup ................................................................................................................................. 13
3.1 Powerup ......................................................................................................................... 13
3.1.1 Safety checks before energizing system ........................................................................ 13
3.1.2 Energizing the system ................................................................................................ 13
3.2 Graphical user interface .................................................................................................... 14
3.2.1 Display module .......................................................................................................... 15
3.2.2 Menu tree ................................................................................................................. 17
3.3 Security .......................................................................................................................... 18
3.3.1 Login and logout ........................................................................................................ 18
3.4 System setup .................................................................................................................. 20
3.4.1 Network Settings screen ............................................................................................. 20
3.4.2 Protocol Settings screen ............................................................................................. 21
3.4.3 Email Settings screen ................................................................................................. 23
3.4.4 General Settings screen .............................................................................................. 24
3.4.5 Display Settings screen .............................................................................................. 25
3.4.6 Information screen ..................................................................................................... 26
3.4.7 User-Interface Board (UIB) ......................................................................................... 27
4 Alarms and Events .................................................................................................................. 28
4.1 Overview ........................................................................................................................ 28
4.2 Product description .......................................................................................................... 28
4.3 Event Log and alarm/warning ............................................................................................ 28
4.3.1 Overview .................................................................................................................. 28
4.3.2 Viewing events .......................................................................................................... 28
4.3.3 Acknowledging events ................................................................................................ 29
4.3.4 Event filtering ............................................................................................................ 31
4.3.5 Alarm/warning annunciation (Local) ............................................................................. 32
4.3.6 Alarm/warning annunciation (Remote) ......................................................................... 33
4.3.7 Group Fault ............................................................................................................... 33
5 Metering and Monitoring .......................................................................................................... 34
5.1 Overview ........................................................................................................................ 34
5.2 Product description .......................................................................................................... 34
5.3 Features ......................................................................................................................... 34
5.4 Modbus ........................................................................................................................... 34
5.5 Metering screens.............................................................................................................. 35

TruFit™
Power Distribution Unit│94-1100-00002874 A0 EN 9
5.5.1 Metering Overview screen ........................................................................................... 35
5.5.2 PDU metering ............................................................................................................ 35
5.5.3 Panel and Branch Metering screens .............................................................................. 39
5.5.4 Sub-feed Metering screens .......................................................................................... 48
5.5.5 Custom Groups .......................................................................................................... 51
5.5.6 Input status screens ................................................................................................... 54
5.6 Setting alarm/warning limits and ratings ............................................................................. 56
5.6.1 PDU configuration settings .......................................................................................... 57
5.6.2 Panel configuration settings ........................................................................................ 60
5.6.3 Branch configuration settings ...................................................................................... 63
5.6.4 Sub-feed configuration settings ................................................................................... 67
5.6.5 Thermocouple configuration settings ............................................................................ 69
6 Specifications ......................................................................................................................... 70
6.1 Standards ....................................................................................................................... 70
6.2 Electrical characteristics .................................................................................................... 71
6.3 Environmental characteristics ............................................................................................ 71
7 System maintenance ............................................................................................................... 72
7.1 Tightening torques ........................................................................................................... 72

10 94-1100-00002874 A0 EN│TruFit™ Power Distribution Unit
—
Figures
Figure 3-1: Home screen with ABB bar highlighted .......................................................................... 14
Figure 3-2: Display module - Front view as mounted on door ........................................................... 15
Figure 3-3: Display module - Rear view ......................................................................................... 16
Figure 3-4: Security Login screen .................................................................................................. 18
Figure 3-5: Password Keyboard..................................................................................................... 18
Figure 3-6: The "Settings" submenu .............................................................................................. 20
Figure 3-7: Network Settings screen (Dynamic) .............................................................................. 20
Figure 3-8: Network Settings screen (Static) .................................................................................. 20
Figure 3-9: Protocol Settings screen .............................................................................................. 21
Figure 3-10: Modbus TCP configuration .......................................................................................... 21
Figure 3-11: Modbus RTU configuration ......................................................................................... 22
Figure 3-12: Secure Shell configuration card .................................................................................. 22
Figure 3-13: TFTP Server configuration tile ..................................................................................... 22
Figure 3-14: Email Settings screen ................................................................................................ 23
Figure 3-15: General Settings screen ............................................................................................. 24
Figure 3-16: Display Settings screen ............................................................................................. 25
Figure 3-17: System Information screen ........................................................................................ 26
Figure 3-18: System Software screen ............................................................................................ 26
Figure 3-19: Slot Information screen ............................................................................................. 27
Figure 4-1: Events log ................................................................................................................. 29
Figure 4-2: Event Log with active warning ...................................................................................... 29
Figure 4-3: Event Log with active alarm & un-acknowledged ............................................................ 30
Figure 4-4: Event ‘Ack all’ is pressed ............................................................................................. 30
Figure 4-5: Event Filters window ................................................................................................... 31
Figure 4-6: Event screen with ‘‘Alarm’ and ‘Warning’ filters enabled................................................... 31
Figure 4-7: Event screen showing the filter criteria .......................................................................... 32
Figure 5-1: Metering Overview screen ............................................................................................ 35
Figure 5-2: PDU Graphical screen - Output side .............................................................................. 36
Figure 5-3: PDU Graphical screen - Input side ................................................................................ 36
Figure 5-4: PDU Tabular screens ................................................................................................... 37
Figure 5-5: PDU Thermal screen ................................................................................................... 38
Figure 5-6: PDU Waveform Capture screen ..................................................................................... 38
Figure 5-7: PDU Waveform Capture Save screen ............................................................................. 39
Figure 5-8: Panel and Branch Main screen ...................................................................................... 39
Figure 5-9: Panel Graphical screen ................................................................................................ 40
Figure 5-10: Panel Tabular screens ................................................................................................ 41
Figure 5-11: Panel Waveform Capture screen ................................................................................. 42
Figure 5-12: Panel Waveform Capture Save screen ......................................................................... 42
Figure 5-13: Branch Status screen, 1-pole breaker .......................................................................... 43
Figure 5-14: Branch status screens, 2-pole breaker ......................................................................... 44
Figure 5-15: Branch status screens, 3-pole breaker ......................................................................... 45
Figure 5-16: Branch Waveform Capture screen 1-pole breaker ......................................................... 46
Figure 5-17: Branch Waveform Capture screen 2-pole breaker ......................................................... 46
Figure 5-18: Branch Waveform Capture screen 3-pole breaker ......................................................... 47
Figure 5-19: Branch Waveform Capture Save screen ....................................................................... 47
Figure 5-20: Sub-feed Graphical screen ......................................................................................... 48
Figure 5-21: Sub-feed Tabular screens .......................................................................................... 49
Figure 5-22: Sub-feed Waveform Capture screen ............................................................................ 50
Figure 5-23: Sub-feed Waveform Capture Save screen .................................................................... 50
Figure 5-24: Metering Overview screen with groups ........................................................................ 51
Figure 5-25: Groups of Meters screen ............................................................................................ 51
Figure 5-26: Custom Group screen – Branches and Panels ............................................................... 52
Indice
Altri manuali ABB Generatore portatile

ABB
ABB J2007003L005 Manuale utente

ABB
ABB EBN853 Manuale utente

ABB
ABB WA4-14 Manuale utente

ABB
ABB EBN853 Manuale utente

ABB
ABB SACO 16D3 Manuale elenco delle parti

ABB
ABB 4000-WIND-INTERFACE-EU Manuale utente

ABB
ABB RPC S-series Istruzioni per l’uso

ABB
ABB Turbocharger TPL-A Series Manuale utente

ABB
ABB EAN823 Manuale utente