ABB RELION REF615R Manuale di installazione e funzionamento

Relion® Protection and Control
REF615R
Engineering Manual


Document ID: 1MRS240044-IB
Issued: 2013-11-22
Revision: A
Product version: 4.0
© Copyright 2013 ABB. All rights reserved

Copyright
This document and parts thereof must not be reproduced or copied without written
permission from ABB, and the contents thereof must not be imparted to a third party,
nor used for any unauthorized purpose.
The software or hardware described in this document is furnished under a license and
may be used, copied, or disclosed only in accordance with the terms of such license.
Trademarks
ABB and Relion are registered trademarks of the ABB Group. All other brand or
product names mentioned in this document may be trademarks or registered
trademarks of their respective holders.
Warranty
Please inquire about the terms of warranty from your nearest ABB representative.
ABB Inc.
Distribution Automation
4300 Coral Ridge Drive
Coral Springs, FL 33065, USA
Toll-free: 1 (800) 523-2620
Phone: +1 954-752-6700
Fax: +1 954 345-5329
http://www.abb.com/substationautomation

Disclaimer
The data, examples and diagrams in this manual are included solely for the concept or
product description and are not to be deemed as a statement of guaranteed properties.
All persons responsible for applying the equipment addressed in this manual must
satisfy themselves that each intended application is suitable and acceptable, including
that any applicable safety or other operational requirements are complied with. In
particular, any risks in applications where a system failure and/or product failure would
create a risk for harm to property or persons (including but not limited to personal
injuries or death) shall be the sole responsibility of the person or entity applying the
equipment, and those so responsible are hereby requested to ensure that all measures
are taken to exclude or mitigate such risks.
This product has been designed to be connected and communicate data and information
via a network interface which should be connected to a secure network. It is the sole
responsibility of the person or entity responsible for network administration to ensure a
secure connection to the network and to take the necessary measures (such as, but not
limited to, installation of firewalls, application of authentication measures, encryption
of data, installation of anti virus programs, etc.) to protect the product and the network,
its system and interface included, against any kind of security breaches, unauthorized
access, interference, intrusion, leakage and/or theft of data or information. ABB is not
liable for any such damages and/or losses.
This document has been carefully checked by ABB but deviations cannot be
completely ruled out. In case any errors are detected, the reader is kindly requested to
notify the manufacturer. Other than under explicit contractual commitments, in no
event shall ABB be responsible or liable for any loss or damage resulting from the use
of this manual or the application of the equipment.

Conformity
This product complies with the directive of the Council of the European Communities
on the approximation of the laws of the Member States relating to electromagnetic
compatibility (EMC Directive 2004/108/EC) and concerning electrical equipment for
use within specified voltage limits (Low-voltage directive 2006/95/EC). This
conformity is the result of tests conducted by ABB in accordance with the product
standards EN 50263 and EN 60255-26 for the EMC directive, and with the product
standards EN 60255-1 and EN 60255-27 for the low voltage directive. The product is
designed in accordance with the international standards of the IEC 60255 series and
ANSI C37.90. This IED complies with the UL 508 certification.

Safety information
Dangerous voltages can occur on the connectors, even though the
auxiliary voltage has been disconnected.
Non-observance can result in death, personal injury or substantial
property damage.
Only a competent electrician is allowed to carry out the electrical
installation.
National and local electrical safety regulations must always be followed.
The frame of the IED has to be carefully grounded.
When the plug-in unit has been detached from the case, do not touch
the inside of the case. The IED case internals may contain high voltage
potential and touching these may cause personal injury.
The IED contains components which are sensitive to electrostatic
discharge. Unnecessary touching of electronic components must
therefore be avoided.
Whenever changes are made in the IED, measures should be taken to
avoid inadvertent tripping.


Table of contents
Section 1 Introduction............................................................................5
This manual..............................................................................................5
Intended audience....................................................................................5
Product documentation.............................................................................5
Product documentation set..................................................................5
Document revision history...................................................................6
Related documentation........................................................................6
Symbols and conventions.........................................................................7
Symbols...............................................................................................7
Document conventions........................................................................7
Functions, codes and symbols............................................................8
Section 2 IED engineering process.....................................................13
Monitoring and control system structure.................................................16
Standard configuration concept..............................................................17
Workflow.................................................................................................19
Section 3 PCM600 tool........................................................................23
Connectivity packages............................................................................24
PCM600 and IED connectivity package version.....................................25
PCM600 projects....................................................................................25
Communication between PCM600 and the IED.....................................26
Section 4 Setting up a project.............................................................27
Installing connectivity packages.............................................................27
Installing connectivity packages by using the connectivity
package installer................................................................................27
Installing connectivity packages by using the Update Manager........27
Activating connectivity packages............................................................28
Setting up IP addresses..........................................................................29
Creating a new project............................................................................30
Building the plant structure.....................................................................31
Inserting an IED......................................................................................32
Inserting an IED in online mode........................................................33
Inserting an IED in offline mode........................................................40
Inserting an IED from the template directory.....................................41
Inserting an IED by importing a .pcmi file..........................................43
Table of contents
REF615R 1
Engineering Manual

Setting the IED IP address in a project...................................................44
Technical key..........................................................................................46
IEC 61850 naming conventions to identify an IED............................47
Setting the technical key....................................................................49
COM600 project......................................................................................52
Importing an IED in a COM600 project..............................................52
Using the Web HMI.................................................................................56
IED User Management...........................................................................57
Section 5 Protection and control engineering......................................61
Application Configuration tool.................................................................61
Function blocks..................................................................................62
Signals and signal management.......................................................63
Function block execution parameters................................................64
Execution order and feedback loops.................................................65
Configuration parameters..................................................................66
Connections and variables................................................................66
Hardware channels............................................................................67
Validation...........................................................................................68
Validation when creating an application configuration..................68
Validation on demand...................................................................69
Validation when writing to the IED................................................70
Parameter Setting tool............................................................................70
Configuration parameter....................................................................71
Setting parameter..............................................................................71
Setting group.....................................................................................71
IED parameter import and export......................................................71
IED parameter organization...............................................................72
Signal Matrix tool....................................................................................72
Load Profile tool......................................................................................75
Opening and closing Load Profile tool...............................................75
Load Profile tool user interface..........................................................78
Information fields...............................................................................79
Fault Record tool....................................................................................79
Opening and closing Fault Record tool.............................................79
Fault Record tool interface................................................................81
Section 6 LHMI engineering................................................................83
Single-line diagram engineering.............................................................83
Diagrams in Graphical Display Editor................................................83
Display window and sequence order............................................84
Table of contents
2REF615R
Engineering Manual
Altri manuali per RELION REF615R
4
Indice
Altri manuali ABB Staffetta

ABB
ABB TA 450 DU V1000 Manuale utente

ABB
ABB C571 Manuale utente

ABB
ABB REU 523 Manuale utente

ABB
ABB CM-MSS.12 Manuale utente

ABB
ABB RELION REF610 Manuale del prodotto

ABB
ABB REX 521 Manuale per l'uso e la cura

ABB
ABB REB650 Manuale utente

ABB
ABB ITH-T Series Guida

ABB
ABB CM-TCN Manuale utente

ABB
ABB Relion REX610 Manuale utente

ABB
ABB HCB Manuale

ABB
ABB ELR96 Manuale utente

ABB
ABB SPAM 150 C Manuale elenco delle parti

ABB
ABB CM-UFD.M22 Manuale utente

ABB
ABB Sentry USR22 Manuale utente

ABB
ABB Relion REC670 Guida rapida

ABB
ABB CIRCUIT SHIELD 437W Series Manuale utente

ABB
ABB SPACOM 300 Manuale utente

ABB
ABB EF19 Manuale utente

ABB
ABB C6701 Manuale utente