Abnova Precipitor 32 Manuale utente

Affinity Magnetic Precipitation System
USER MANUAL
Precipitor 32
®

Table of Contents
Check list
Safety Items
Chapter 1 Introduction of Precipitor
Chapter 2 Introduction of LCD
Chapter 3 The picture of wiring at the
back of controller
Chapter 4 I/O Chart
Chapter 5 Troubleshooting guide
Chapter 6 Specication
Chapter 7 Program import/export
Chapter 8 AutoMag software
1
2
3
6
13
13
14
15
16
17

www.abnova.com 1
Check List
Documents
● User manual
● Quality control checklist
Accessories
● USB to serial converter driver disc
● USB to RS-232 transmission line
● RS-232 to USB connection line
● Magnetic base
Consumables
● 4X 96 deep well plates
● 8X 8-channel strips

2
Precipitor 32
®
Safety Items
Caution!
Notice these tips below for avoiding electric shock or re accidents.
1. Do not touch any plugs and electric switches with wet hands.
2. Turn off and unplug the machine before moving it.
3. Fasten robot before moving and delivering the machine.
4. Put the machine in a room with good ventilation. Keep more than ve centimeters
around the machine.
5. Hold the plug while you are pulling it out of an outlet. Do not pull the electric wire
directly.
6. Do not place electric wires on any subject with high temperature.
7. Do not look steadily at the ultraviolet lamp while it is on.
8. Disconnect the plug from the power source when the machine is not used.
9. Do not mend the machine by yourself. Make contact with our service center or
agencies to deal with problems.
Warning
Please remove the two xing screws inside the internal compartment before turning
on the machine. The two screws were used to hold the magnetic rod set during
shipping, and it has to be REMOVED before turning on the power. This is a very
important step. If not, the instrument will experience malfunction and break.

www.abnova.com 3
Introduction
What is Automatic Platform for Magnetic System?
Preciptor 32 is a robot designed to handle magnetic reagent assays. It is popularly
applied to the extraction of nucleic acids/proteins and the separation of cells.
Users just need to put samples into a pre-lled reagents plate. Then, combining a
96-deep-well plate and a specially-designed strip, the Preciptor 32 can automatically
handle 32 samples simultaneously.
Also, the extraction process of the magnetic system is simplier than that of the spin
column system and still achieves scientic and diagnostic requirements with relatively
quick, easy, and safe operating procedures.
How to perform?
Preciptor 32 uses magnetic rod to transfer magnetic beads from one well to another
and strip to mix solution. By moving the strip up and down to mix solution well,
you can get clean nucleic acids after cells lysis, nucleic acids absorption, wash and
elution.
Operation interface is simple.
There are five parts in operation interface: Select Program Screen, Perform Temp
Screen, Perform UV Lamp Screen, Perform Program Screen and Control Panel. The
control panel includes 7 buttons and uses LED light to indicate operator.
Heating system
The heating system can provide reagents with the best working temperatures.
All temperatures are programmed. In Perform Program Screen, “PRESET” is
programming temperature and “PRESENT” is real temperature on stainless steel board.
The heating system is connected with the main power system. Switch off both of the
main power and heating switch when you turn your machine off. If you are not going
to start this function next time, please remember to turn it off.
There is a light on the heating switch and it will be lit up as the heating is functioning.
Meanwhile, the temperature of stainless steel board will raise and please keep clear of
the machine.

4
Precipitor 32
®
Appearance of the Machine
Front view Back view
Control Panel
Switches and Electrical Inlet (voltage: 100~240V, fuse: 5A/250V)
(A) Heating switch
(B) Main power switch
(C) USB port
(D) Electrical inlet
Internal view
(A) Magnetic rod frame
(B) Strip rack frame
(C) 96 deep well plate rack
(D) 8-channel strip
(E) 96 deep well plate
D
A
B
C
A
B
D
E
C

www.abnova.com 5
: LED light-up indicates users to press the button. Start bottom LED
is green, and others are red.
: to initiate the program.
: to terminate the program. It shows “ ” at status row at the rst
time you press the button. Press the button again to conrm to stop
the program. Then the robot will be back to the initiated site.
: Press the button to turn buzzer-beater off.
: It stops temporarily when you press the button. Press the button
again to continue program, and the time will be recalculated.
: 1. Press the button to select the previous program or a number.
2. From .
: Conrm the program or the number you select.
Move down: Press the button to select the next program or a number.

6
Precipitor 32
®
Introduction of LCD
I. Time Setting
Turn on the machine after pressing the button . After 3 seconds, the screen
will automatically show time setting as below.
Time Setting Screen:
Press the buttons or to select the key-in position. Then, press the
button to confirm it. The way to select numbers is to press the buttons
or , and change the digits from 0 to 9. Finally, press the button to
conrm the number you select. The years are started from A.D.. Insert the last two
digits. For example, insert 08 for 2008 A.D. on the screen. It’s 24 hour system.
Please restart the machine after setting the date and the time.
II. Opening Screen
These words will show up on the screen in ve seconds after turning on the power
system of the machine.
Welcome to Precipitor
afnity magnetic precipitation system

www.abnova.com 7
III. Select Program Screen
: The name of the program is no more than 15 characters.
: It display the last program number you used. You can pre-load 100 programs,
code number from 00 to 99.
: Insert the number of the program to select the program directly.
The way to insert digits is to press the button or . Select the digits
from 0 to 9.
Then press the button to conrm it.
TEMP :Press the button or to select the TEMP, then press the button
to enter the “Perform Temp Screen”.
: Press the button or to select the UV Lamp, then press the
button to enter the “Perform UV Lamp Screen”.
IV. Perform Temp Screen
PRESENT : Real working temperature. (℃)
PRESET : Set temperature of bottom stainless plate, RT~65. (℃)
PROGRAM : Return to the “Select Program Screen” after turning off Heater.

8
Precipitor 32
®
Introduction of TEMP
1. Press the button or to select key-in position and return to “Select
Program Screen”. Then press the button to conrm it.
2. PRESET setting: Press the button or to change the digits from
RT to 70, then press the button to conrm it.
3. Heater ON/OFF: Press the button to turn on or the button to turn
off heater.
V. Perform UV Lamp Screen
: Set working time of UV Lamp. ( hh : mm )
: Start time of UV Lamp ( hh : mm : ss )
: End time of UV Lamp ( hh : mm : ss )
: The present status of UV Lamp (ON or OFF)
: Return to the “ ” after turning off UV Lamp.
: It shows current time in the right lower corner. Time is 24-hour format
Indice
Manuali Attrezzature da laboratorio popolari di altre marche

Agilent Technologies
Agilent Technologies 5800 ICP-OES Manuale utente

Endress+Hauser
Endress+Hauser Cleanfit CPA875 Manuale utente

NI
NI PXI-5422 Manuale

Collomix
Collomix Aqix Manuale utente

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series Manuale utente

Ocean Insight
Ocean Insight FLAME-NIR+ Manuale utente