Technical Specication..................................................................................................................... 4
Product Overview .............................................................................................................................. 4
Features ................................................................................................................................................. 4
ACTEnterprise Support .................................................................................................................... 4
Applications ......................................................................................................................................... 5
Installation ............................................................................................................................................ 6
Enabling IOM communications from the keypad. ........................................................ 6
Conguration....................................................................................................................................... 7
Step 1............................................................................................................................................. 7
Step 2............................................................................................................................................. 8
Step 3............................................................................................................................................. 10
Elevator Control .................................................................................................................................. 12
Step 1............................................................................................................................................. 12
Step 2............................................................................................................................................. 12
Step 3............................................................................................................................................. 13
Step 4............................................................................................................................................. 14
Step 5............................................................................................................................................. 14
Step 6............................................................................................................................................. 14
ACTpro Input Output Module
Model No. ACTpro IOM
Note: This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at
his own expense.

Installation and Conguration Instructions for the ACTpro IOM Input/Output Module
4
Copyright © 2016 Access Control Technology Ltd. Part No.18-00039 Issue 2.0
Technical Specication
Voltage 12V DC
Current Consumption 250mA
Communications RS485 to ACTpro controller
Operating Temperature -10ºC to +50ºC / +14°F to +122°F
Mounting Surface
Installation Indoors
Weight 500g / 1.102lb
Dimensions 236mm wide, 165mm high, 55mm deep
9¼"wide x 6½" high x 2¼" deep
Product Overview
This product is an 8 Input/8 Output device that allows the ACTpro controller to be used in
applications where signalling to other equipment is required. Examples of this are elevator
control, alarm systems, CCTV switching and general monitoring.
A maximum of 4 Input/Output Modules may be connected to any single controller, giving
control of up to 32 relays and 32 inputs per ACT4000/ACT1520.
Features
• 8 form C relays
• 8 supervised inputs
• Tamper protection
• 3 status LED's
• Timer for each output
• Input Timer
• Output switched ON/OFF by log event, input or timezone
• ACTEnterprise support
ACTEnterprise Support
• Named inputs and outputs
• Inputs and outputs Logged
• Normally open/closed.
• Active on timezone
• Active on event, user, door or user group
• Active on input on/o
• Active on output on/o

Installation and Conguration Instructions for the ACTpro IOM Input/Output Module
5
Copyright © 2016 Access Control Technology Ltd. Part No.18-00039 Issue 2.0
Applications
Elevator control
In this application, a user presents a card to the proximity reader when he enters the cab.
This enables the buttons for the storeys the user has access to. The buttons stay on for a
programmable amount of time (normally 5 seconds) and then switch o.
Intruder Alarm Systems
The unit can be programmed to re a relay on alarm events such as tamper, door forced,
mains fail etc. It can also monitor the status of certain inputs and switch an output when
the input changes state. All changes are fully logged in ACTEnterprise, complete with
timestamp.
Building Management
The Input/Output Module allows the ACTpro controller to be used in building management
applications. It can switch an output to turn on heating or lighting at certain times or only
when someone is present. It can also switch o heating when the last person has left the
room, saving on energy costs.
CCTV systems
Using an Input/Output Module allows switching of CCTV cameras when someone enters a
room or when access is denied.

Installation and Conguration Instructions for the ACTpro IOM Input/Output Module
6
Copyright © 2016 Access Control Technology Ltd. Part No.18-00039 Issue 2.0
Installation
Please see the diagram on the last page for complete wiring.
The Input/Output module is wired to the controller on the same RS-485 network as the
ACTpro100e door stations. The Input/Output Modules are addressed using the DIP
switches on the PCB. Input/Output Modules are given any address in the range 1 to 4.

Installation and Conguration Instructions for the ACTpro IOM Input/Output Module
7
Copyright © 2016 Access Control Technology Ltd. Part No.18-00039 Issue 2.0
Conguration
All IOM Input/Output Module congurations are performed from ACTEnterprise.
Step 1.
The Input/Output Module conguration is available from ACTInstall, under Advanced
Setup.
Click on Add I/O Module on the top right.
Give the Input/Output Module a name and assign it a controller and the local address.
This number must be the same as the dipswitch setting on the IOM. Remember to tick the
Enabled box. Finally, click the Save button on the bottom right. The IOM is now setup on
the system.

Installation and Conguration Instructions for the ACTpro IOM Input/Output Module
8
Copyright © 2016 Access Control Technology Ltd. Part No.18-00039 Issue 2.0
Step 2.
Run ACTManage and go to the Inputs tab under Manage.
Clicking on the input name goes to the input details.
The input name may be edited from here. This is the name that will appear in the log when
the input changes state.
The Timer option selects the amount of time the input must remain in a certain state
before the change is reported. This prevents a momentary change in the input from
causing a false alarm.

Installation and Conguration Instructions for the ACTpro IOM Input/Output Module
9
Copyright © 2016 Access Control Technology Ltd. Part No.18-00039 Issue 2.0
Inputs can be enabled by timezone and when an output is on. If any inputs are unused,
simply set the Time Zone to Not Active and the Output to No Output. For example, you
may want the input to be monitored only during the day or only when a particular output is
on.
The input may be set to activate an output or to open a door.
The Normally Open option allows the input to be in the normal state when the contact is
open and active when the contact is closed.
If the Supervised option is checked, then two 4k7 resistors are required (see the wiring
diagram at the end of the manual). This allows the IOM to check for tampers and shorts
across the input contacts.

Installation and Conguration Instructions for the ACTpro IOM Input/Output Module
10
Copyright © 2016 Access Control Technology Ltd. Part No.18-00039 Issue 2.0
While the input is enabled, it can be logged (if the Log tick box is checked) or it can
generate an Alarm when it goes active.
Step 3.
From ACTManage, go to the Outputs tab.
Click on an output name to edit it.
Each output can be assigned an individual name. The Timer value selects how long the
relay res for. By selecting a timezone from the Active Timezone drop-down box, the
relay can be made activate during this timezone.
Altri manuali per ACTPRO IOM
2
Indice
Altri manuali ACT Sistema I/O
Manuali Sistema I/O popolari di altre marche

WAGO
WAGO 750-344 Manuale utente

Teknim
Teknim TWM-1887 Manuale di istruzioni

Intelligent Appliance
Intelligent Appliance IA-2662-E Manuale utente

BERGHOF
BERGHOF ECC DIO 16/16 Manuale di istruzioni

Advantech
Advantech PCM-27J3AU Manuale di installazione e funzionamento

Festo
Festo CP-E08-M12-CL Manuale utente