AEG DD8691 Scheda tecnica

DD 8691
Dunstabzugshaube
Afzuigkap
Hotte aspirante
Cooker Hood
Montage- und Gebrauchsanweisung
Installatie- en gebruiksaanwijzing
Notice d utilisation et d installation
Operating and Installation Instructions

61
Contents
Safety warnings 62
fortheuser 62
fortheinstaller 62
Description of the Appliance 64
Extractorversion 64
FilterVersion 64
Hood Operation 65
Maintenance and care 67
Metalgreasefilter 67
Openthemetalgreasefilter 67
Charcoalfilter 68
Changingthelightbulb 69
Cleaning 70
Special accessories 70
Technical assistance service 70
Guarantee Conditions 71
Technic Details 73
Mountingaccessoriesincluded 73
Electrical connection 73
Safetywarningsfortheelectrician 73
Wall unit mounting 74

62
Safety warnings
for the user
•Alwayscoverlighted elements, to prevent excessheatfrom
damaging the appliance. In the case of oil, gas and coal fired
cookers it is essential to avoid open flames.
•Also, when frying, keep the deep frying pan on the cooker top/
cookerundercarefulcontrol.
•Thehotoil in the fryingpanmight ignite due tooverheating.
•The risk of self-ignition increases when the oil being used is dirty.
•It is extremely important to note that overheating can cause a fire.
•Never carry out any flambécooking under the hood.
•Always disconnect the unit from the power supply before
carrying out any work on the hood, including replacing the
light bulb (take the cartridge fuse out of the fuse holder or switch off
theautomatic circuit breaker).
•It is very important to clean the hood and replace the filter at
the recommended intervals. Failure to do so could cause
grease deposits to build up, resulting in a fire hazard.
for the installer
•When used as an extractor unit, the hood must be fitted with a
150mmdiameterhose.
•Should there already be a pipe of diameter 125 mm that ducts to the
outside through the walls or roof, it is possible to use the 150/125
mm reduction flange provided. In this case the hood will be slightly
noisier.
•When installing the hood, make sure you respect the follow-
ing minimum distance from the top edge of the cooking hob/
ringsurfaces:
electric cookers 600 mm
gascookers 650 mm
coal and oil cookers 700 mm min.
•ThenationalStandardonfuel-burning systems specifies a maximum
depression of 0.04 bar in such rooms.
•The air outlet must not be connected to chimney flues or combus-
tion gas ducts. The air outlet must under no circumstances be
connectedtoventilationductsforroomsinwhichfuel-burning
appliancesareinstalled.
•Itisadvisabletoapplyforauthorizationfromtherelevantcontrolling
authority when connecting the outlet to an unused chimney flue or
combustion gas duct.

63
The air outlet installation must comply with the regulations laid down
bytherelevantauthorities.
•When the unit is used in its extractor version, a sufficiently large
ventilationholemustbeprovided,withdimensionsthatare
approximately the same as the outlet hole.
•Nationalandregionalbuildingregulationsimposeanumberof
restrictionsonusinghoodsandfuel-burningappliancesconnected
to a chimney, such as coal or oil room-heaters and gas fires, in the
sameroom.
•Hoods can only be used safely with appliances connected to a
chimneyiftheroomand/orflat(air/environmentcombination)is
ventilatedfromoutsideusingasuitableventilationholeapproxi-
mately 500-600 cm2 large to avoid the possibility of a depression
beingcreatedduringoperationofthehood.
•Ifyouhaveany doubts, contact the relevant controllingauthorityor
buildinginspector’soffice.
•Since the rule for rooms with fuel burning appliances is “outlet hole
of the same size as the ventilation hole”, a hole of 500-600 cm2,
which is to say a larger hole, could reduce the performance of the
extractorhood.
•If the hood is used in its filtering function, it will operate simply and
safelyin the above conditions without the need for any of the
aforementionedmeasures.
•When the hood is used in its extractor function, the following rules
mustbefollowedto obtain optimal operation:
—short and straight outlet hose
—keep bends in outlet hose to a minimum
—never install the hoses with an acute angle, they must
always follow a gentle curve only
—keep the hose as large as possible (preferably the same diameter
as the outlet hole).
•Failure to observe these basic instructions will drastically reduce the
performanceandincreasethenoiselevelsoftheextractorhood.

64
Description of the Appliance
Extractor version
•The hood is supplied as an extractor unit
and can also be used with a filtering
functionbyfitting one charcoal filter
(special accessory).
•Youwill need originalAEG charcoal filter
for this function (see Special
Accessories).
•The air is discharged to the outside
through a pipe, which must be fitted to
connection flange D. Fig. 1.
•Inordertoobtainthe best performance the
hoseshouldhavea diameter equal to the
outlethole.
Shouldtherealreadybeapipe of diameter
125 mm that ducts to the outside through
the walls or roof, it is possible to use the
150/125mmreductionflangeprovided.In
this case the hood will be slightly noisier.
Filter Version
•Theairisfilteredthroughan
charcoalfilterandreturnedto
the kitchen through the top
grill of the outlet pipe.
•You will need an original AEG
charcoalfilterforthe
filteringfunction.(SeeSpecial
Accessories).
•Fix the deflector using 4
screws Ø3x6.5 mm. Fig. 2.
•Optionally, the position of the
chimney elements can be
changed.
When using the hood in the
filterversionthechimney
must be fixed at the top, with
the air outlet grill at the side.
Fig. 1
D
Fig. 2

65
Hood Operation
•Best results are obtained by using a low speed for normal conditions
andhighspeedwhenodoursaremoreconcentrated. Turn the hood
on a few minutes before you start cooking then you will get an
underpressurein the kitchen. It should be lefton after cooking for
about15minutesoruntilallodourshavedisappeared.
The control switches are located on the unit’s front panel:
A- Main switch, hood OFF (stand by).
B- Start and choice of motor speed 1-2-3-1-2.........
C- Indicatesspeed1(LED) and indication of the greasesaturation
forthefilter(flashingindicator).
D- Indicatesspeed2 (LED) and indication of thecharcoalsaturation
forthefilter(flashingindicator).
E- Indicatesspeed3(LED)
F- Indicates Intensive speed (LED).
G- Intensivespeedon/off.The Intensive speed runsfor5minutes:
Ifthehood is on whentheIntensive speed is activated,the hood
revertstopreviousspeedafter5minutes.
Ifthehood is off when the Intensivespeedis activated, the hood
will automaticly be turned off after 5 minutes.
To interrupt the Intensive speed, press button A,B or G.
H- Light ON/OFF
Should the hood or the controls fail to operate: disconnect the power
supply for at least 5 seconds, then turn the hood back on again.

66
LED Indicator lights for veryfying the
saturation of filters
This hood is supplied without a charcoal filter. If the hood is to be used
in the recirculation mode with a charcoal filter, the saturation indicator
must be activated as follows:
Depress and hold the A and B buttons simultaneously for 3 seconds.
Initially only the LED indicator signal for the grease filter C is activated,
shortly after the LED indicator for the charcoal filter D will activate, at
this point the saturation detection has been enabled.
To switch off the saturation detection : depress and hold the A and B
buttons for 3 seconds until the LED indicator for the active carbon filter
isflashing.
Led –Indicator for grease filter C
The LED indicator for the grease filter will flash when it requires
cleaning.
Follow the maintenance instructions.
Led - indicator for charcoal filter D
TheLEDindicatorfor the charcoal filter illuminateswhenthefilter
requiresreplacing.
Thisoccursafterabout160workinghoursfromwhentheactivecarbon
filter was first put into operation.
Resetting the saturation indicator
Aftercleaning or replacing the filter depress and hold the G and H
buttons again for 3 seconds until the grease filter LED C or the charcoal
LEDDarenolongerflashing.
Warning! Theresetting of the saturationindicator MUST be donein
stand by, never disconnect the hood from the mains.

67
Maintenance and care
•The hood must always be disconnected from the electricity
supply before beginning any maintenance work.
Metal grease filter
•Thepurpose of the grease filters is toaspirate grease particles
which form during cooking and it must always be used, either in the
externalevacuationorinternalrecyclingfunction.
Attention:themetal grease filters must beremoved and washed,
eitherbyhandor in the dishwasher, every fourweeks.
Open the metal grease filter
•Extract the metal grease filter stop backwards and release the filter
pullingdownwards.Fig. 4.
Hand washing
Soakgreasefiltersforabout one
hourinhot water with agrease-
looseningcleaner,thenrinseoff
thoroughlywithhotwater.Repeat the
process if necessary. Refit the
greasefilters when they are dry.
Dishwasher machine
Place grease filters in dish washer.
Selectmostpowerfulwashing
programmeandhighesttemperature,
at least 65°C. Repeat the process.
Refitthe grease filters when they are dry.
When washing the metal grease filter in the dishwasher a slight
discoloration of the filter can occur, this does not have any impact
onitsperformance.
•Cleantheinnerhousingusingahotdetergentsolution only (never
usecausticdetergents,abrasivepowdersorbrushes).
Fig. 4

68
Charcoal filter
•The charcoal filter should only be used if you want to use the hood
in its filtering function.
•To do this you will need an original AEG charcoal filter (see special
accessories).
•Cleaning/replacing the charcoal filter
Unlikeothercharcoal filters, the LONGLIFE charcoalfiltercan be
cleanedandreactivated. At normal use the filtershould be cleaned
everysecondmonth (when using thehood2,5 hours per day,in
avarage). The best way to clean the filter is in the dishwasher. Use
normaldetergentandchoose the highest temperature (65ºC). Wash
the filter separately so that no food parts gets stuck on the filter and
latercauses bad odours. Toreactivatethe charcoal, the filtershould
bedriedin an oven for 10minuteswith a temperature of maximum
100ºC.
After approximately three years of use, the charcoal filter should be
replaced with a new, as the odour reduction capacity will be
reduced.
•Mounting
Remove the frame iwhich supports the filter hby turning 90°the two
knobs g, Fig.5. Insert the coal mattress inside the frame and put
all parts back in their place.
•To dismount proceedinreverseorder.
•Alwaysspecifythe hood model code numberandserial number
whenorderingreplacementfilters.Thisinformationisshownonthe
registration plate located on the inside of the unit.
•Thecharcoalfilter can be ordered fromtheAEG technical
assistanceservice.
Fig. 5
g
g
i
h

69
Warning
•Failuretoobserve the instructions on cleaningtheunit and changing
thefilters will cause a fire hazard. You are therefore strongly
recommendedtofollowtheseinstructions.
•Themanufacturerdeclinesall responsibility for any damage tothe
motororanyfiredamagelinkedtoinappropriatemaintenanceor
failuretoobserve theabovesafetyrecommendations.
Changing the light bulb
•Disconnect the cooker hood from the main supply.
•Remove the lampcover, use ascrew driver as a lever. Fig. 6.
•Replace the old bulb with a new one of the same type.
•Remountthelamp cover.
•If the light does not come on, make sure the bulb has been inserted
in correctly before contacting the technical assistance service.
Fig. 6
Indice
Altri manuali AEG Cappa di ventilazione

AEG
AEG DCK5970HM Manuale utente

AEG
AEG DCE5980HM Manuale utente

AEG
AEG X66453MDO UK Manuale utente

AEG
AEG DEB1621S Manuale utente

AEG
AEG DPE4941M Manuale utente

AEG
AEG DK 4370 Scheda tecnica

AEG
AEG DPB3640M Manuale utente

AEG
AEG 502 D Manuale utente

AEG
AEG DI 8610 Manuale utente

AEG
AEG DPB0901W Manuale utente