.04
.05
.06
.07
.08
.09
.11
.12
.13
.14
.15
.16
.17
.24
.10
.18
Packing
Description
Technical features
Products and dimensions
Usage
Pipes connection
Safety
Painting cycle
Pressure discharge
Maintenance
Cleaning
Filter and gasket replacement
Anomaly resolution
Scheduled maintenance
Spare parts and components
Disposal and Support
Instruction manual
WARNINGS!
Carefully read and follow all instructions and safety precautions
before using the product.
MANUALS
Our manuals are available at aircom.it/en/support/manuals/
Or, by scanning the QR Code on this page.

aircom.it .04
OBBLIGO DI
IMPIEGO DI
OCCHIALI E
MASCHERINA
PACKING
The pump is packed in a cardboard box. All components supplied as
standard are placed in the same package.
The weight of the equipment plus the packaging is ~27 Kg.
STORAGE
During transport and storage, make sure that temperatures between -15°C
and 40°C or 50°C for short periods not exceeding 24 hours are not
exceeded, which could damage the unit itself.
If the unit is to be stored, make sure it is stored in places with humidity
between 30% and 80%.
PLATE DATA
On the front plate, the equipment bears the manufacturer's identification
plate and the 2006/42/CE STANDARDS compliance plate, also represented
below.
The plate must not, under any circumstances, be removed, even if the
equipment is resold. For any communication with the manufacturer, always
quote the serial number (shown on the plate itself). On the body of the
pump there are some pictograms indicating safety warnings which must be
carefully observed by anyone preparing to use the painting unit. Failure to
comply with the provisions relieves the manufacturer from any damage or
injury to people or things that could derive from it and makes the operator
himself solely responsible towards the competent bodies. Replace the
nameplate and any removed, damaged or illegible stickers.
EN

aircom.it .05
The equipment covered in this manual is a painting unit which allows you to
spray paint any type of material. Characterized by considerable practicality,
versatility and ease of use, the AST30 employs a pneumatically operated
high-capacity piston pump unit.
The airless spray system allows to considerably reduce the paint mist and
to guarantee a great transfer efficiency (over 80%). The system also makes
it possible to obtain perfect micro-atomization with considerable savings in
paint and a better surface finish.
The modularity of the equipment allows you to purchase only the pump unit
and then customize it with a considerable number of accessories (AIRLESS
GUN, PUMP HOLDER TROLLEY, GRAVITY TANK, SELF-CLEANER, etc.)
DESCRIPTION
EN

TECHNICAL FEATURES
aircom.it .06
The painting unit uses a pneumatic system that can be fed at a pressure
between 6 and 8 bar. Compressed air is used to obtain the movement of
the paint pumping piston and to obtain a high spraying pressure with any
type of paint and to obtain a high spraying pressure with any type of
paint without the use of air. All gaskets are of a special type with high
quality and high resistance; the valves are in stainless steel, the seats
are in hard metal.
FEATURE AST30
CAPACITY
PRESSURE RATIO
OPERATING PRESSURE
NOMINAL PRESSURE
DROP TANK
PREVALENCE
AIR OUTLET FITTING
PAINT INLET FITTING
NOZZLE
WEIGHT
SOUND PRESSURE LEVEL
PEAK VALUE
6.5Lt/min.
30:1
240 bar
8 bar
5 Lt.
50 metres
¼”M
F 3/4” 90°
0,007 – 0.026
30 kg.
Laeq=75 dB (A)
99,7 dB
EN

aircom.it .07
The AST30 painting units are designed for painting large surfaces and for
uses such as: painting on behalf of third parties, shipyards, large and
medium-sized carpentry shops, industrial body shops, mechanical
constructions in general. The products that can be supplied are: high solid
paints, normal paints, primers and glues. For the use of the equipment with
particular products, the approval of the manufacturer must be obtained, and
the adaptation of the technical characteristics of the unit for the processing
of such products.
Solvents such as trichloromethane and chloromethylene (dichloromethane)
can chemically react with the aluminum which makes up most of the pump,
leading to dangerous explosions. We advise you to always read the technical
data sheet of the product you intend to apply very carefully, avoiding the
use of materials that contain this type of solvent. Do not use regenerated
solvents (cleaning thinners), make sure they are free from acids (caused by
regeneration); these acids are responsible for the corrosion of the pistol.
PRODUCTS AND DIMENSIONS
EN

aircom.it
Before using the paint pump, check that it has not suffered damage due
to transport or storage conditions.
Also check that all the optionals ordered and all the components supplied
as standard are contained in the packaging.
Always wear the prescribed PPE; gloves, mask, goggles, in compliance
with workplace safety regulations. As a first step, it is necessary to make
sure that the lines are able to correctly feed the pump, in compliance
with the safety standards.
The unit is supplied with a condensate filter with regulator, it is
recommended to feed with a pressure of 8 bar Max.
It is recommended to use dry compressed air for best painting results.
.08
USAGE
EN

aircom.it
The unit is supplied disassembled. To assemble the pipes, proceed as
follows (using the following drawing):
• Screw the pipe with the suction filter (E) or the 5 Lt tank to the
attachment (1) of the unit.
• Screw the paint return pipe (F) to the connection (2) of the unit.
• Connect the compressed air network to the inlet (M) of the pressure
regulator (L).
• Connect the paint hose of the gun (B) to the fitting (3) of the unit.
• Connect the ground.
.09
PIPES CONNECTION
1
L
2
3
E
F
B
M
• Check the connections before activating the system.
• Do not kink tubing near fittings, and do not use damaged or worn
tubing.
• Do not try to repair any leaks.
• Pay close attention to the writing on the pipes.
• Do not exceed the maximum pressure indicated by the
manufacturer.
• Given the high power of the pump (up to 240bar), we recommend
the use of certified and tested guns up to 300 bar.
EN

aircom.it .10
The painting MUST preferably take place in a special painting booth
equipped with a suction hood. Do not use the unit if the vacuum system
is not running. Wear protective gloves, goggles and a mask with filters
for breathing with activated carbon and clothing suitable for body
protection.
The pneumatic piston pump must only be used by competent and trained
personnel for its safe and correct use. Make sure that the personnel
assigned to use it have received adequate training and have fully
understood this user manual. To use the spray gun, COMPLY STRICTLY
with the prescriptions and safety criteria indicated below.
• Always work on the equipment protected by the prescribed PPE; gloves,
protective masks, breathing filters with activated carbon, clothing suitable
for body protection.
• The pump is used with paint products or solvents, bear in mind that
these are highly flammable, therefore use the system in well-ventilated
environments and avoid any action that could cause fires (example:
smoking, high temperature slag or shavings, sparks or any electrical
risk).
• CHECK the chemical compatibility of the products to be used from their
safety data sheets.
• The use of products containing organic solvents can cause poisoning
due to the emission of toxic vapours.
• DO NOT USE with food or medicines.
• DO NOT EXCEED the maximum operating pressures indicated (see
paragraph 2.3). BEFORE any disassembly, cleaning, maintenance and
reassembly operation RELEASE the pressure in the pipes
• Never point the paint gun at the human body or at animals.
• Do not modify or alter the equipment as supplied; in addition to being
able to cause malfunctions, or worse, even dangerous failures, you would
invalidate the guarantee.
SAFETY
EN
Indice
Altri manuali AirCom Pompa dell'acqua
Manuali Pompa dell'acqua popolari di altre marche

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guida alla risoluzione dei problemi

DUROMAX
DUROMAX XP WX Series Manuale utente

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuale utente

Franklin Electric
Franklin Electric IPS Manuale utente

Xylem
Xylem e-1532 Series Manuale utente

Milton Roy
Milton Roy PRIMEROYAL Manuale utente