AJAX WallSwitch Manuale utente

WallSwitch User manual
Updated September 30, 2019
WallSwitch is a device that combines a wireless power on/off relay for
electrical appliances and a power consumption meter. The miniature body
of the device is adapted for installation in a European type socket.
WallSwitch should be only installed by a qualified electrician! Regardless of the type of the
electrical circuit in which the device is installed.
WallSwitch operates only with the Ajax security system (it may not be used
in any third-party security systems), by connecting via the
protected Jeweller protocol to the hub. Communication range –up to 1,000
meters, absent any obstacles.
Operates only with Ajax hubs. Connection to ocBridge and uartBridge integration modules is not
provided.
The Ajax security system is self-sustaining, but the user can connect it to
the central monitoring station of a private security company.
Buy power relay WallSwitch

Functional Elements
1. Antenna
2. Terminal blocks
3. Functional button
4. Light indicator
IN terminals:
L terminal —power supply phase terminal.
N terminal —power supply neutral terminal.
OUT terminals:
N terminal —connected device neutral output contact terminal.
L terminal —connected device phase output contact terminal.

WallSwitch Operating Principle
The WallSwitch input terminals are connected to the mains, and the output
terminals are connected to the socket or electrical appliance/electrical
system of the room. WallSwitch turns on/off 230 V power supply according
to the scenarios or at user command via the Ajax Security System application.
WallSwitch is furnished with a protection system against voltage variation
beyond the range of 161V –264V or overcurrent protection above 13А. In
this case, the power supply is interrupted, resuming after normalization of
the voltage and current values.
The maximum resistive load on the relay is 3 kW.
You may view the consumed power of the electrical appliances connected
via WallSwitch through the application. There is a consumed electricity
meter in place.
Connecting to the hub
Before starting connection:
1. Following the hub instruction recommendations, install the Ajax
application on your smartphone. Create an account, add the hub to the
application, and create at least one room.
2. Go to the Ajax application.
3. Switch on the hub and check the internet connection (via Ethernet cable
and/or GSM network).
4. Ensure that the hub is disarmed and does not start updates by checking its
status in the mobile application.
5. Connect WallSwitch to the power supply and wait for 30 seconds.
Only users with administrative privileges can add the device to the hub.

How to connect the WallSwitch to the hub:
1. Select the Add Device option in the Ajax application.
2. Name the device, scan/write manually the QR Code (located on the body
and packaging), and select the location room.
3. Select Add —the countdown will begin.
4. Press the WallSwitch functional button (or apply the load to the device no
less than 20 W, e.g. by switching on an iron or electric kettle).
For the detection and interfacing to occur, the device should be located within the coverage area
of the wireless network of the hub (at a single protected object).
Request for connection to the hub is transmitted for a short time at the time
of switching on the device.
If the connection to the hub fails, wait for 30 seconds and retry the
connection procedure.
The WallSwitch connected to the hub will appear in the list of devices of the
hub in the application. Update of the detector statuses in the list depends
on the device inquiry time set in the hub settings, with the default value –
36 seconds.
When switching on for the first time, the relay is in open status! After deleting WallSwitch from
the system, the Ajax switch opens the relay!

States
1. Devices
2. WallSwitch

Parameter
Value
Signal Strength
Signal strength between the hub and the relay
Connection
Connection status between the hub and the relay
Active
State of the relay (turned on/off)
Voltage
The current input voltage level of WallSwitch
Current
Current at the relay input
Power
Current consumption in W

Electric energy consumed
The electric power consumed by the device connected to the
relay. The counter is reset when the relay loses the power
Firmware
Device firmware version
Device ID
Device identifier

Settings
1. Devices
2. WallSwitch
3. Settings

Setting
Value
First field
Device name, can be edited
Room
Selecting the virtual room to which the device is assigned
Current protection
If active, power supply will be switched off if the strength of
current exceeds 13 A, in the inactive state the threshold is 19,8
A (or 16 A, if continues for 5 seconds)
Voltage protection
If active, power supply will be switched off in case of a voltage
surge beyond the range of 161 –264 V, in the inactive state —0
–500 V
React to arming/disarming
Selecting a script for the relay in case of arming/disarming
Switching off the relay
Switching on the relay
Do not react
The relay can respond separately to both the arming and
disarming
React to night mode
If active, the arming / disarming scenarios will also work in the
night mode
Signal Strength Test
Switches the device to the signal strength test mode
User Manual
Opens the WallSwitch User Manual
Unpair Device
Disconnects the relay from the hub and deletes its settings
Indication
The WallSwitch light indicator may light up green depending on the device
status.
The green LED of WallSwitch will blink intermittently if it is not assigned to
the hub. When the functional button is pressed, the green LED lights up.

Functionality testing
The Ajax security system allows conducting tests for checking the
functionality of connected devices.
The tests do not start straight away but within a period of 36 seconds when
using the standard settings. The test time start depends on the settings of
the detector scanning period (the paragraph on “Jeweller” settings in hub
settings).
Signal Strength Test
Installation of the Device
WallSwitch should be only installed by a qualified electrician! Regardless of the type of the
electrical circuit in which the device is installed
WallSwitch is designed for installation inside a socket box with the diameter
50 mm and more and the depth no less than 70 mm. The relay can also be
installed within extension cords and other circuits powered by 230 V.
Communication range with the hub absent any obstacles between the
devices –up to 1,000 meters. Take account of this when choosing the
location for WallSwitch.
If the device has a low or unstable signal strength, use a radio signal range
extender ReX.
Altri manuali per WallSwitch
5
Indice
Altri manuali AJAX Staffetta