Alfa Network FILTER UNI 2.2 Manuale utente

ALFA IN a.s. © www.alfain.eu FILTER UNI 2.2 manual EN 02
FILTER UNI 2.2
INSTRUCTION MANUAL

2/18
ALFA IN a.s. © www.alfain.eu
OBSAH
1. INTRODUCTION ....................................................................................... 3
2. SAFETY PRECAUTIONS ......................................................................... 4
3. TECHNICAL DATA ................................................................................... 5
4. DESCRIPTION OF THE APPLIANCE ....................................................... 6
5. GETTING STARTED ................................................................................. 8
6. MAINTENANCE ...................................................................................... 10
7. DISPOSAL .............................................................................................. 18
8. WARRANTY LIST ................................................................................... 18

3/18
ALFA IN a.s. © www.alfain.eu
1. INTRODUCTION
Dear Consumers!
Company ALFA IN a. s. thanks you for buying our filtration equipment and
believe that you will be satisfied with our machine.
FILTER UNI 2.2 is intended for the local exhausting of pollutants generated
during welding. The filter can be equipped with one or two suction arms.
Air pollutants generated during welding are fed to a three-part filter set, where
mechanical particles are trapped. At devices equipped with fourth filtration stage
with activated carbon are also trapped gaseous pollutants. Thereafter,
the cleaned air is discharged back to the work area by means of a fan.
FILTERS UNI 2.2 meet the requirements of the CE brand and are manufactured
in the EU.
We reserve the law of adjustments and changes in case of printing errors,
change of technical parameters, accessories etc. without previous notice.
These changes may not be reflected in the manuals for use in paper or electronic
form.

4/18
ALFA IN a.s. © www.alfain.eu
2. SAFETY PRECAUTIONS
1. Before use, the instructions given in this instruction manual must be read
carefully.
2. All safety regulations must be observed when using electrical devices,
to avoid electric shocks, equipment damage, or fire.
3. UNI FILTER must not be used for suction easily flammable or explosive
substances. The UNI FILTER is designed for the suction of welding
pollutants, not for other applications.
4. Protect the mains cable from high temperatures, oils and sharp edges.
5. The machine must be well stabilized, wheels with the brake must be braked.
6. Before any interference in electrical part, removing the cover or cleaning,
the device should be disconnected from the network.
7. Putting the machine into operation can be performed only by trained
personnel and only within the technical provisions. The manufacturer is not
liable for damages resulting from improper use or handling.
For maintenance and repair, use only original spare parts from ALFA IN.
8. The machine must be positioned so that the air can exit the vents without
restriction.
9. The handling handle is intended for moving only, it is not designed for lifting
the machine.
10. All interventions in the el. equipment as well as repair should be performed
by an authorized person.
11. With competent mains voltage and input must match the plug.
12. It is necessary to protect the machine against:
a. Moisture and rain
b. Mechanical damage
c. Draft and possibly ventilation of neighboring machines
d. Rough treatment
e. Chemically aggressive environments

5/18
ALFA IN a.s. © www.alfain.eu
3. TECHNICAL DATA
Suction arm pcs 1
Mains voltage V/Hz 1x230/50
Machine air flow rate m3/h 1480
Maximum extractor fan flow rate m3/h 2500
IP protection class
IP 55
Filtration efficiency according to EN 1822 (G2) % 25
Filtration efficiency according to EN 1822 (G4) % 70
Filtration efficiency according to EN 1822 (E12) % 99,5
ISO insulation class
F
Sound pressure level db (A) 73
Dimensions (w x l x h) mm 600 x 800 x 1200
Weight without arm kg 100 kg

6/18
ALFA IN a.s. © www.alfain.eu
4. DESCRIPTION OF THE APPLIANCE
MAIN PARTS
Figure 1 – Main parts of the machine
Pos. Description
A1 Suction arm
A2 Handle
A3 Control panel
A4 Wheel with brake
A5 Door for filters replacement
A6 Exhalation and carbon filter attachment point

7/18
ALFA IN a.s. © www.alfain.eu
CONTROL PANEL
Figure 2 – Control panel
Pos. Description
V1 ON/OFF switch
V2
LED diodes
fan on
self-cleaning valves on
(if function enabled)
dirty filter warning (600 h)
clogged filter warning
(on – if function enabled)
V3 Display
V4 Control buttons
V5 OFF button
V6 ON button

8/18
ALFA IN a.s. © www.alfain.eu
BUTTON LAYOUT
Figure 3 – Button layout
5. GETTING STARTED
ARM ASSEMBLY
Depending on the model, the FILTER UNI is equipped with one or two suction
arms.
Screw the suction arm tightly by means of the enclosed screws through the holes
in the flange to the holes in the top cover.
GETTING STARTED
1. Switch on the machine with the mains plug. The mains connection must
correspond to the technical parameters of the respective hood type in this
manual.
2. Turn the machine on by rotating the ON/OFF switch V1 to the position ON
and then long pressing the ON button (pos. V6) on the control panel, the
ON button lights up.
3. If the LED V2 – DIRTY FILTER on the control panel lights up, it is
necessary to clean or replace the filters.
4. The other buttons V4 are used to control the specific functions, which differ
according to the specifications shown on the V3 display.
5. Adjust the suction arm so that the suction nozzle will be placed from the
side 30 – 50 cm above the welding point.
6. After finishing the work, turn the machine off by means of the long pressing
the OFF button (pos. V5) – the OFF button lights up, then rotate the
ON/OFF switch V1 to the position OFF – the OFF button goes out.
MACHINE CONTROL
Turn the machine on by means of the long pressing the ON button (pos. V6).
After finishing the work, turn the machine off by means of the long pressing the
OFF button (pos. V5). The other buttons V4 are used to control the specific
functions, which differ according to the specifications shown on the V3 display.

9/18
ALFA IN a.s. © www.alfain.eu
SPECIFICATIONS SHOWN ON THE DISPLAY
Model / status (ON / OFF)
Hour meter
Filter clogging alarm (pressure switch)
Dirty filter alarm (600 h)
Serial number
The navigation between the various screens is done using the ▲ and ▼ buttons.
After pressing any button, the V3 display automatically returns to the original
display of model / status after 60 seconds. If there are active alarms, the main
screen is displayed in alternation with the alarm screen in which the numerical
code of the alarm is indicated and the descriptive message.
MENU AND PASSSWORD
There are 4 menus:
Test menu
User menu
Service menu
Factory menu
The navigation between the various screens is done using the ▲ and ▼ buttons,
the selection of a submenu or exit from a menu is done by pressing ENTER
above the corresponding item. Changing a menu item (if enabled) occurs using
the - and + buttons. In menu mode the arrows ↑ and ↓ are shown on the display
to indicate whether the buttons ▲ and ▼ are enabled, the symbols - and + if the
modification of the menu item is enabled and the symbol ↲ if the ENTER button
is enabled (the entry is associated with the access to the submenu or exit from
the menu).
Access to the user, service and factory menus is performed with the machine
switched off by means of the long pressing special buttons combination and the
password.
Menu Buttons combination Password
User ENTER
ENTER, ENTER,
ENTER, ENTER,
ENTER, ENTER

10/18
ALFA IN a.s. © www.alfain.eu
The user menu consists of the following items:
LANGUAGE: language selection for menu displays (except test menu,
only in English) and status / operation
EXIT: exit from the menu
MACHINE SPECIFIC FUNCTIONS
Hour meter
Stores the count of hours the machine has been ON, with a 10 minutes resolution
(the count displayed is in hours). The count of hours is saved automatically every
10 minutes, so if the machine loses electric power the maximum operating time
lost in the ON state is 10 minutes. When an alarm occurs the hour meter is saved
immediately, so in case of loss of power supply immediately after an alarm
nothing goes lost.
Alarms / warnings
Alarms and warnings are generated in the event of an anomaly only with the
machine ON. To restore them it is necessary to turn the machine off, enter the
service menu - reset alarms and enter the appropriate password. After the
restoration if anomaly conditions persist alarms / warnings will be generated
again when the machine is turned ON. Alarms not restored are re-activated in
case of disconnection and subsequent connection of the power supply. Below is
the list of alarms as they appear on the display V3:
W01 – DIRTY FILTER: dirty filter warning (threshold defined by the DIRTY
parameter FILT. EDGE of the factory menu, which can be disabled, only
for the machines with analogic pressure switch or 600 h)
W02 – EXHAUST FILTER: warning of exhausted filter (threshold defined
by the parameter EXHAUST F. EDGE of the factory menu or by the digital
pressure switch if enabled)
6. MAINTENANCE
FILTERS REPLACEMENT
The service life of the filters and the replacement intervals vary according to the
different applications of the extractor. If the filter is clogged, the LED V2 – DIRTY
FILTER on the control panel lights up.
Filters compartment door A, B, C must be unlocked. First pull the filter frame C
(bottom). The other two filters can then be removed more easily.
Indice
Altri manuali Alfa Network Scrubber