Intended purpose
PocketChem Printer is a dedicated thermal recording printer for use with
PocketChem BA (PA-4140) and PocketChem UA (PU-4010), which are intended for
the qualitative, semi-quantitative and/or quantitative measurement of several
physiological markers. For in vitro diagnostic use and professional use only. This
instrument is not intended for near-patient testing use.
This product conforms to the EMC Standard IEC61326-2-6:2012(EN61326-2-6:2013).
Class of emission: CISPR 11 Class A
This instrument is IVD medical instrument.
This product conforms to Regulation (EU) 2017/746.

Symbols
The following symbols are used in this manual and the labels on this instrument to call
your attention to specific items.
For Your Safety
Unpacking
The package should contain the components listed below. Check to see if everything
is included. If anything is missing or damaged, contact your distributor.
NOTE: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the
interference at his own expense.
The electromagnetic environment should be evaluated prior to operation of the
device. Do not use this device in close proximity to sources of strong
electromagnetic radiation, as these may interfere with the proper operation.
The printer must be directly attached to the instrument in order to
use it. Therefore, the printer can also be contaminated by pathogenic
microorganisms. Take care when attaching, detaching and storing
the printer to prevent exposure to pathogenic microorganisms.
Follow the instructions given here to prevent exposure to pathogenic
microbes.
PocketChem printer Printer paper
Operating manual
(this manual)
Stylus pen
(Stored in the printer)

Materials Required but Not Provided
• PocketChem BA PA-4140
• PocketChem UA PU-4010
• Power code
• AC adapter
Printer Specifications
For Use
Follow the procedure below to attach/detach the printer to/from the instrument.
This operating manual uses the PocketChem UA (PU-4010) as an example.
For further details, please refer to the operating manual that came with the
PocketChem.
Printer Thermal recording printer
Printer paper High color development thermal paper (W58 mm × Ø26 mm)
Operating environment Temperature: 10-35°C; Humidity: 25-85% RH
Measurement environment Temperature: 10-35°C; Humidity: 25-85% RH
Storage environment Temperature: 1-35°C; Humidity: 20-85% RH (Non-condensing)
Environment during
transport
Temperature: -10-60°C;
Humidity: 20-85% RH (Non-condensing)
Dimensions 125 (W) × 133 (D) × 36 (H) mm
Weight 180 g (without printer paper)
Power supply AC adapter 7.5 V 3 A
Power consumption 20 W
Attachment One-touch attachment
Connection Contact
Expected life 5 years from first use (installation) of instrument (according to
company data)
NOTE: Turn off the power and disconnect the AC adapter from the AC outlet
before attaching or detaching the printer. Failure to do so may cause damage to
the instrument and printer. The printer may print nonsense if it is accidentally
attached or detached while connected to the AC outlet. However, this does not
mean that there is something wrong with the printer.

If you need to obtain technical assistance,
please contact ARKRAY Europe, B.V.
84-10013
Issued: 2022.10.06
How to Attach
1. Place the instrument onto the printer at an
angle as shown in the figure.
2. Press the top of the instrument to snap it into
place.
3. Make sure the top of the instrument and printer
are horizontally level with one another and that
both units are firmly locked to each other.
How to Detach
1. Place the instrument on a level surface (such
as a desk).
2. While pressing on the casing above the display
at a point aligned with the center of the display
(a), lift up the reading unit cover from the
bottom (b).
NOTE: The printer runs on AC power only, not on batteries.
Once the printer is attached to the instrument, connect the instrument through
the printer to an AC outlet.
Indice