ARTHUR HOLM AHDTL Manuale utente

User Guide
Danish craftmanship
Mediterranean soul
Technology Serving Desing
AHDTL
Universal motorised lift system for gooseneck microphones


TABLE OF CONTENTS
EC REGULATIONS AND SECURITY 6
SAFETY INSTRUCTIONS 6
APPLICATIONS 8
FEATURES 9
BOX CONTENTS 9
CONTROLS 10
CONNECTIONS 12
PRODUCT HANDLING 14
AHNET PROTOCOL 15
AHLINK 18
INFORMATION ON DISPOSAL 21
WARRANTY TERMS AND CONDITIONS 22

WELCOME
Thank you very much for acquiring an Arthur Holm product.
Our mission is to provide meeting rooms with solutions featuring exclusive
design and innovative technology to optimise space, share information
and help the decision-making.
Our vision is to facilitate communication through innovative and exclusive
design technology that integrates seamless in the furniture design.
Please, read this guide carefully. If you have any suggestions that might
help us to improve our products, we would be pleased to receive them.
Thank you again and we hope that you enjoy the Arthur Holm experience!
Henrik Holm
General Manager

ABOUT US
The Company
Arthur Holm has its origins in the Danish furniture designer Jorgen Alex
Jensen, who was active during the sixties and the seventies. His design
inspiration and his concept of ergonomics have been continued by his
family, the design force behind Arthur Holm product range. The result of
combining Scandinavian design tradition with Mediterranean creativity,
exibility and emotion is a wide product range built on more than 20 years
of craftsmanship.
Arthur Holm offers a professional product range where tomorrow’s
technology is shaped into valued materials with design exibility and
customisation, specially created to enhance communication and
collaboration in reception, conference and meeting areas.
The art of customisation
Arthur Holm offers a range of ingenious products whose designs are based
on quality materials and the latest technology. Products which endow
meeting and conference rooms with silent, ergonomic, innovative and
aesthetic solutions that integrate into the furniture, hang from the walls as
works of art or are used as interactive points of information.
The world of Arthur Holm
Arthur Holm offers a selection of unique, elegant, versatile, exible and
ergonomic products that are being used in meeting and conference
rooms, reception areas, auditoriums and public zones of leading
companies throughout the world.
The numbers speak for themselves! We currently own 27 product
patents,have presence in over 45 countries with products and solutions
inmore than 20,000 installations.
It will be our pleasure to work with you, designing your unique environment.
Our broadcast electronic engineers will provide the latest technology
while our design team will offer you the most exclusive appearance.
Our team puts its heart, passion and pride in all our designs.

6
SAFETY INSTRUCTIONS
Plugs
• Do not dismantle any part of the equipment power connector.
• Disconnect the power plug from the AC outlet when the equipment is
not going to be used for an indenite period of time.
Power and extensions cords
• Use the appropriate power cord with the correct plug type.
• Do not overload wall outlets or power cords.
• Make sure the total ampere passed through an extension cord does not
exceed the maximum allowed by the cable used.
• Do not place anything on the power cord.
• Do not locate this product where a person may walk or trip over the
cord.
EC REGULATIONS AND SECURITY
ATTENTION: Do not disassemble or modify the device in any way.
This symbol warns of the presence of dangerous un-insulated
voltages inside some of the components, of sufcient magnitude
to expose people to risk of electronic shock.
This symbol draws attention to important use and maintenance
instructions in the manual that accompanies the unit.
This symbol indicates that the equipment conforms to the norms
established by the European Community.

7
Wiring connected to hazardous voltage requires installation by
qualied personnel or the use of ready-made exible cables.
For your security, your equipment must be connected to an
electrical outlet with grounding connection protection.
Since the plug is used to disconnect the device, the operating
electrical outlet must be in an easily accessible place.
Environment
• Install the equipment on an elevated, at surface.
• Install the equipment in a ventilated area.
• Avoid exposing the equipment to:
∙Rain or water
∙Excessive heat, cold or humidity
∙Area exposed to direct sunlight
∙Dirty areas
∙Equipment generating strong magnetic elds
• Avoid placing open containers of liquid, near the equipment.
• Keep a minimum distance of 30 mm in order to have good ventilation.
• Never place above the device any sources of ames such as lighted
candles, etc.
• If you are using the device in extreme weather conditions and/
or tropical climates, the equipment should be installed in a room
which ensures a reasonable level of temperature and humidity.
• To prevent damage, the equipment must be rmly anchored to the
surface, as shown in the installation instructions.
SAFETY INSTRUCTIONS

8
SAFETY INSTRUCTIONS
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy, and if not installed and used
in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected
• Consult the dealer or an experienced AV technician for help
APPLICATIONS
DynamicTalk is an elegant retractable system for gooseneck
microphones with exclusive features. It not only makes the microphone
disappear within the desk surface but it also provides a pleasant light
to indicate its status. Thanks to its protective and patented lighting
ring, the microphones can be safely stored and protected making
meeting and conference spaces more flexible and versatile.
DynamicTalk provides two different working modes: PA and
Conference. When in PA mode, a push button placed on the stainless
steel cover plate allows to activate or de-activate the microphone,
and the LED ring will indicate the status by changing colour from red
to green. The system will automatically silence the microphone when

9
retracting. When in Conference model, the microphone will always be
active and both the light ring and the access to the push button on
the cover plate will be available via GPI and GPO for remote control.
DynamicTalk is available in 3 sizes: for 400 mm, 500 mm and 600
microphones. The system can be adjusted to the exact length of the
microphone via AHnet and AHlink. The AHlink is an excellent tool to
diagnose, verify and configure DynamicTalk.
Features
• Universal lift system for gooseneck XLR 3 pin microphones
• Stainless steel cover plate with 3 buttons
• LED lighting ring to indicate microphone status, 360º
• Serial control and remote diagnosis
• Individual addressing
• AH-AMMC Auto Mechanical Movement Calibration
• PA and Conference working modes
Box Contents
Before the installation of your DynamicTalk, please check the contents
of the shipping box, it must contain the following items:
• DynamicTalk
• Power cord
• Power supply 100-240Vac, 50-60Hz. Output 12V
• User Manual
Important Note: This device can only work with the power supply
included in the shipping box. This power supply can not be replaced by
any other rather than the original one.
Caution! Never use this monitor in horizontal position.
APPLICATIONS

10
CONTROLS
On the upper cover plate, there are three buttons to control the
functions and to externally control other devices (GPO).
1. UP/DOWN: Controls the elevation and retraction of the microphone
lift. Press this button during 2 seconds to activate AHlink signal (5
beeps sound when AHlink signal is activated).
2. Customised: The central push button is used to control external
devices. The contact close button (GPO) is present on the GPO
connector to externally control other devices. Contact close of the
GPO pins 7, 8 while pressing this button.
3. TALK or GPO: The third push button has two different functions:
• PA mode: In PA mode, this button is used as the MUTE function.
Press the button once and the LED ring will appear in red indicating
that the MUTE function is deactivated and it's ready for the user to
talk to the audience. Press the button again to activate the MUTE
function and silent the microphone, which will be indicated by the
green LED ring. The contact close button (GPO) is present on GPO
connector to externally control other devices. Contact close of the
GPO pins 9, 10 while pressing this button.
Altri manuali per AHDTL
2
Indice
Altri manuali ARTHUR HOLM Sistema di sollevamento
Manuali Sistema di sollevamento popolari di altre marche

Genie
Genie Z-60/34 Manuale utente

Screen Technics
Screen Technics INTERFIT Vertical Up Lift Manuale utente

Mortuary Lift
Mortuary Lift ULTIMATE 1000 Manuale utente

Custom Equipment
Custom Equipment Hy-Brid 3 Series Manuale di programmazione

Custom Equipment
Custom Equipment Hy-Brid Lifts 2 Series Manuale di programmazione

Hy-Brid Lifts
Hy-Brid Lifts HB-P3.6 Manuale di programmazione














