10
EN
ÂCharging status
Charging Not charging
As soon as a renewable charging
source is properly connected, the Con-
nection Status Indicator switches from
Off to On.
When the energy source provides
enough energy to charge the device,
the Charing Status Indicator arrow will
ll up.
3) DC Output On/Off Indicator
The right side indicator arrow shows, if
the DC outlets (USB, 12V) are
operational.
DC On DC Off
Top Display
The device has the following display
elements and buttons on its topside.
1) Battery Voltage Level
The device indicates the charge level
of connected batteries in Volt and a
5-bar scale. As default, its settings
are adjusted to the appropriate device
batteries.
ÂVoltage indicator
ÂBar indicator
ÂPicture indicator
The voltage indicator is the most pre-
cise way to gain information about the
charge level of your device. For more
information, please see the section “the
battery”.
2) Renewable Input Status Indicator
The PV status indicator shows if your
renewable energy source is connected
properly and if it is providing energy to
the system.
ÂConnection Status
Display and Indicators
Understanding the device signals
Status indicator LEDs (4)
The status indicator LEDs provide
information about the AC inverter.
1) RED: AC error status indicator
This LED indicates an inverter Error
caused by too much load. Turn the AC
inverter off and disconnect all con-
nected electrical AC devices and make
sure the power requirements do not
exceed 1000 Watt in total.
To reset the device, turn the AC inverter
switch (2) off and on again.
2) ORANGE: Overheating indicator
This LED indicates an overheating of
the inverter over 60°C/140°F. Turn the
AC inverter off and disconnect all con-
nected electrical AC devices. Move the
device to a cool place and let the device
cool down.
Do not try to speed up the cooling
process by exposing the device to ice,
water or any other cooling aid.
1 2 3
3) GREEN: AC status OK indicator
This LED indicates a successful internal
system check and that the AC outlet is
ready to be used.
Audio warnings
Your device comes with an internal
speaker for audio warnings.
Long beep
This warning eccurs when the con-
nected electrical devices briey exceed
1000W in combined power. If the
overload persists for more than a few
seconds, the inverter will go into error
mode and shut off.
Periodic beeps
This warning is given when the battery
is near depletion. Turn the AC in-
verter off and disconnect all connected
electrical AC devices. Recharge the
battery.
Audio signal range:
The low voltage warning will start
at a battery voltage level of: 23,5V
The device will shut off at a
battery voltage level of : 22,5V
PV Off
On
PV Off
On
To deactivate the Display, put
the device into storage mode by
disconnecting the Battery Breaker
Plug.
The DC outlets are activated auto-
matically when the battery voltage
reaches more than 25V and need
to be deactivated manually.