Azbil ATT085 Manuale utente

ATT085
Advanced Temperature Transmitter
with FOUNDATION fieldbus™ - protocol
Brief User’s Manual
CM2-ATT085-2002

NOTICE
While the information in this manual is presented in good faith and
believed to be accurate, Azbil Corporation disclaims any implied
warranty of merchantability or fitness for a particular purpose and
makes no express warranty except as may be stated in its written
agreement with and for its customer.
In no event shall Azbil Corporation be liable to anyone for any
indirect, special or consequential damages. This information and
specifications in this document are subject to change without
notice.
These Instructions are Brief User’s Manual.
For detailed information, refer to the User’s Manual and other
documentation. These Brief User’s Manual do not act as a substitute
for the User’s Manual included in the scope of delivery.
©2015–2016 Azbil Corporation All Rights Reserved.

i
Safety
■Precautions for Use
For safe use of the product, the following symbols are used in this manual.
WARNING Warnings are indicated when mishandling the product
might result in the death or serious injury of the user.
CAUTION Cautions are indicated when mishandling the product
might result in minor injury to the user or damage to
property.
In describing the product, this manual uses the icons and conventions listed below.
Use caution when handling the product.
The indicated action is prohibited.
Be sure to follow the indicated instructions.
Handling Precautions:
Handling Precautions indicate items that the user should pay attention to
when handling the ATT085.
To use this product correctly and safely, always observe the following precautions.
We are not responsible for damage or injury caused by the use of the product in violation
of these precautions.

ii
■Handling Precautions for This Product
Installation Precautions
WARNING
When installing, use proper fittings and proper tightening torque for connections to
the process and to the exhaust. Gas leakage is dangerous because process gas and
calibration gas are flammable. Please refer to the leak check instructions in this
manual and verify that there is no gas leakage.
Do not use the product except at the rated pressure, specified connection standards,
and rated temperature. Use under other circumstances might cause damage that
leads to a serious accident.
For wiring work in an explosion-proof area, follow the work method stated in the
explosion-proof policy.
CAUTION
After installation, do not step or stand on this unit. Doing so may damage the device
or cause injury.
Bumping the glass of the display with a tool may cause damage or injury. Be careful.
Install the device correctly. Incorrect or incomplete installation will cause output
errors and violation of regulations.
This product is quite heavy. Protect your feet with safety shoes when working.
Do not subject the product to shock or impact.
Wiring Precautions
WARNING
Do not do wiring work with wet hands or while electricity is being supplied to the
product. There is a danger of electric shock. When working, keep hands dry or wear
gloves, and turn off the power.
CAUTION
When wiring, check the specifications carefully and make sure to wire correctly.
Incorrect wiring can cause device damage or malfunction.
Supply electric power correctly according to the specifications. Supplying power that
differs from the specifications can damage the device.
Use a DC power supply that has overload protection.

iii
Maintenance Precautions
WARNING
When removing this device for maintenance, be careful of residual pressure or
residual process gas. Leakage of process gas is dangerous.
When working on the vent, check its direction so that people do not come into
contact with vented gas. There is a danger of burns or other physical harm.
When the device is being used in an explosion-proof area, do not open the cover.
Opening the cover may cause an explosion.
CAUTION
This product was kept under carefully controlled conditions until it was shipped.
Never try to modify this device. Doing so could damage it.

iv

v
Table of Contents
Chapter 1. Identification ..........................................................1
1-1. Nameplate The right device? ...........................................................1
1-2. Scope of delivery ......................................................................1
1-3. Certificates and approvals .............................................................2
1-3-1. CE mark, declaration of conformity ..............................................2
1-3-2. Certification FOUNDATION Fieldbus™ ..............................................2
1-3-3. Korea Certification Mark .........................................................2
Chapter 2. Installation instructions ................................................3
2-1. Incoming acceptance, transport, storage ...............................................3
2-1-1. Incoming acceptance ...........................................................3
2-1-2. Transport and storage ..........................................................3
2-2. Installation conditions .................................................................3
2-2-1. Dimensions .....................................................................3
2-2-2. Installation point ...............................................................3
2-2-3. Important ambient conditions ..................................................3
2-3. Installation instructions ................................................................4
2-3-1. Mounting typical of Europe .....................................................4
2-4. Post-installation check .................................................................4
Chapter 3. Wiring .................................................................5
3-1. Quick wiring guide .....................................................................5
3-2. Connecting the sensor cables ..........................................................6
3-3. Connecting the power supply and signal cables.........................................6
3-3-1. Cable glands or entries ..........................................................6
3-3-2. Shielding and grounding ........................................................7
3-4. Post-connection check .................................................................8
Chapter 4. Operation and commissioning .........................................9
4-1. Function check ........................................................................9
4-2. Display and operating elements (optional) .............................................9
4-2-1. Display..........................................................................9
4-2-2. Display symbols ................................................................9
4-3. Configuration of the head transmitter and FF functions ................................10
4-4. Hardware settings (DIP switches) ......................................................10
4-5. Switching on the head transmitter ....................................................11
Appendix A. Explosion protected models......................................... 13
A-1. FM intrinsically safe, nonincendive and suitable approvals..............................13
Terms and Conditions

vi

1
Chapter 1 Identication
Chapter 1. Identification
1-1. Nameplate The right device?
Compare and check the details on the device nameplate against the measuring point
requirements.
1 6
2
35
0DFC9602-
ATT08 5 -
4
Figure 1-1. Nameplate of the head transmitter (example, Ex version)
1. Device identication number (Device_ID)
2. Power supply and extended order code
3. Serial number and FW release
4. Tag name (TAG)
5. Approval in hazardous area with number of the relevant Ex documentation
6. Order code
1-2. Scope of delivery
The scope of delivery of the device comprises:
• Temperature head transmitter - display as option
• Securing material
• Multilingual hard copy of Brief User's Manual
Note: Please note the accessories of the device in the chapter “accessories” from the User's
Manual.

2
Chapter 1 Identication
1-3. Certificates and approvals
On leaving the factory, the device was in perfect condition from the point of view of safety.
The device complies with the standards EN61010-1 “Protection Measures for Electrical
Equipment for Measurement, Control, Regulation and Laboratory Procedures” and with
the EMC requirements of IEC/EN61326.
1-3-1. CE mark, declaration of conformity
The device meets the legal requirements of the EU Directives. The manufacturer confirms
a positive completion of all tests by fitting the unit with a CE mark.
1-3-2. Certification FOUNDATION Fieldbus™
The device meets all the requirements of the following specifications:
• Certified in accordance with FOUNDATION Fieldbus™specification
• FOUNDATION Fieldbus™H1
• Interoperability Test Kit (ITK), (device certification number available on request): the
device may also be operated using certified devices from other manufacturers
• Physical Layer Conformance Test of the Fieldbus FOUNDATION™
An overview of other approvals and certificates can be found in the User's Manual.
1-3-3. Korea Certification Mark
Altri manuali per ATT085
1
Indice
Altri manuali Azbil Trasmettitore

Azbil
Azbil ATT082 Manuale utente

Azbil
Azbil ATT082 Istruzioni per l’uso

Azbil
Azbil JTD910S Manuale utente

Azbil
Azbil MagneW Plus+ MGG14C Manuale utente

Azbil
Azbil ALTJ 9000 Series Manuale utente

Azbil
Azbil PTG60 Manuale utente

Azbil
Azbil SLX 110 Manuale utente

Azbil
Azbil ATT085 Manuale utente

Azbil
Azbil KDP Series Manuale utente

Azbil
Azbil PREX3000 Manuale utente