Basler BIP2 c Series Manuale utente

For BIP2-XXXXc and
BIP2-XXXXc-dn Models
Document Number: AW000975
Version: 09 Language: 000
Release Date: 22 January 2020
Basler IP
Fixed Box Cameras
Installation
Guide
Installations-
anleitung
dritte
Sprache
fünfte
Sprache
sechste
Sprache
siebente
Sprache
achte
Sprache
vierte
Sprache

Contacting Basler Support Worldwide
Europe, Middle East, Africa
Basler AG Tel. +49 4102 463 515
An der Strusbek 60–62 Fax +49 4102 463 599
22926 Ahrensburg
Germany support.europe@baslerweb.com
The Americas
Basler, Inc. Tel. +1 610 280 0171
855 Springdale Drive, Fax +1 610 280 7608
Suite 203
Exton, PA 19341
Asia-Pacific
Basler Asia Pte. Ltd. Tel. +65 6367 1355
35 Marsiling Industrial Fax +65 6367 1255
Estate Road 3
#05–06
Singapore 739257 support.asia@baslerweb.com
www.baslerweb.com
All material in this publication is subject to change without notice and is
copyright Basler AG.

Installation Guide
Basler IP Fixed Box Cameras 1
EnglishLanguageLanguageLanguageLanguageLanguageLanguageLanguage
Basler IP Fixed Box Camera
Installation Guide
About This Document
This document is intended to help you install your Basler IP Fixed Box
Cameras on a network. This document applies to Basler IP Fixed Box
Cameras that include the designation "BIP2" as part of their model name
(see Table 2 on page 26 for a list of the models covered by this document).
When installation is complete, refer to the camera user’s manual for detailed
information about operation and features. You can find the latest version of the
camera user’s manual (AW000972) in the Downloads section of the Basler
website:
www.baslerweb.com/manuals
Precautions
WARNING
The camera is not designed for unprotected use in an
explosive atmosphere.
If you use the camera in an explosive atmosphere, it must be
enclosed within an appropriate environmental housing.

Installation Guide
2 Basler IP Fixed Box Cameras
CAUTION
Electrical Shock Hazard
Touching the camera’s internal components may result in an
electrical shock.
Do not open the camera housing. The housing contains no user
serviceable parts.
NOTICE
The camera is not designed for unprotected outdoor use and can be
damaged by excessively damp or wet conditions.
If you are using the camera outdoors, you should mount the camera in a
weatherproof housing.
NOTICE
Every time you replace the plastic cap, a lens, or a lens adapter, make sure
that the camera is pointing down.
Never apply compressed air to the camera. This can easily contaminate
optical components, particularly the sensor.

Installation Guide
Basler IP Fixed Box Cameras 3
EnglishLanguageLanguageLanguageLanguageLanguageLanguageLanguage
WEEE Directive
The European Union has enacted Directive 2002/96/EC on Waste Electrical
and Electronic Equipment (the WEEE Directive). This directive is only
applicable in European Union member states.
All Basler IP Cameras have been manufactured after the 31st of August 2005.
NOTICE
Electrostatic discharge (ESD) can damage electronic components.
Make sure that the black, 8-pin Weidmüller plug that is included with the
camera is always inserted into the terminal connector on the back of the
camera. This protects the camera from damage caused by electrostatic
discharge.

Installation Guide
4 Basler IP Fixed Box Cameras
1 Hardware Overview
RJ-45 Network / PoE - Provides a 10/100 Ethernet connection and can be
used to connect Power over Ethernet (IEEE 802.3af) to the camera.
Terminal Connector - Provides connections for an alternate camera
power input, connections for the camera’s I/O ports, and connections for a
standard RS-485 serial port that can be used to control an external device.
DC Iris Control - Provides a connection for a DC auto iris.
Lens Mount - Provides a point to mount a lens on the camera (a 5 mm
extension ring is required if a C-mount lens is used; except for BIP2-
1920-30c which comes with a C-mount adapter that holds the IR-cut filter).
Factory Default Button - Used to return the camera to factory default
settings.
SD Card Slot - Can hold a microSD or a microSDHC card. The card can
be used to store alarm images or the contents of the alarm buffers.
(An SD card is not included with the camera.)
Terminal
Connector
RJ-45
Network/
PoE
DC Iris
Control
Lens Mount
(CS- or C-Mount)
1/4’’ Standard
Tripod Mount
M3 Mounting Holes
(8 total)
Factory
Default
Button
SD Card Slot

Installation Guide
Basler IP Fixed Box Cameras 5
EnglishLanguageLanguageLanguageLanguageLanguageLanguageLanguage
2 Installing the Camera
2.1 Hardware Installation
1. Take the camera and an appropriate lens and move to an environment that
is as dust-free as possible.
2. Remove the cap from the lens mount on the front of the camera.
3. Install the lens on the camera:
If you are using a CS-mount lens, carefully screw your lens into the
mount as far as it will go.
If you are using a C-mount lens, carefully screw a 5 mm extension ring
into the lens mount of the camera as far as it will go and then carefully
screw your lens into the extension ring as far as it will go.
NOTICE
BIP2-1920-30c
This model comes with a C-mount adapter that holds the IR-cut filter.
You can remove the C-mount adapter to use a CS-mount lens but be
aware that this also removes the IR-cut filter. When using a CS-mount
lens, a 0.8 mm spacer is required in addition.
When using a C-mount lens, take care not to insert the lens too deeply
into the lens mount as this can damage the IR-cut filter.
For more information, see the dimension drawings in Chapter 8 of the
user’s manual.

Installation Guide
6 Basler IP Fixed Box Cameras
4. If your lens has an auto-iris mechanism, connect the cable on the lens to
the DC Iris control connector on the side of the camera (see the drawings
on page 4).
5. Make the Ethernet connection and apply camera power.
If power will be supplied to the camera via the Ethernet network cable
(i.e., Power over Ethernet), see section below.
If power will be supplied from an external power supply via the camera’s
terminal connector, see section on page 9.
NOTICE
Electrostatic discharge (ESD) can damage electronic components.
Make sure that the black, 8-pin Weidmüller plug that is included with the
camera is always inserted into the terminal connector on the back of the
camera. This protects the camera from damage caused by electrostatic
discharge.

Installation Guide
Basler IP Fixed Box Cameras 7
EnglishLanguageLanguageLanguageLanguageLanguageLanguageLanguage
If camera power will be supplied via Power over Ethernet (PoE):
6. Connect the camera to a PoE network switch or to a PoE injector as
shown below.
PoE Network Switch
Ethernet
Patch
Cable
PoE Injector
InOut
Ethernet
Patch
Cable
To
Network
Switch
Ethernet
Patch
Cable

Installation Guide
8 Basler IP Fixed Box Cameras
7. If you will be connecting devices to the DC Out, I/O, or RS-485 pins in the
camera’s terminal connector:
a. Read the information in Section 4 regarding the pin numbering and pin
functionality for the terminal connector and determine how you wish to
connect the devices to the camera.
b. Insert the device wires into the black, 8-pin Weidmüller plug on the back
of the camera using the technique illustrated on page 18.
8. Go on to Section 2.2 on page 11.