6
Spectrum 350
1. Consider the use of lighting
within the bathing environment
when determining the Spectrum
350 installation location.
2. Provide electrical service
according to your electric
code to the seelected fixture
installation area. Supply wire
must be rated for at least 194°F
(90°C).
3. Apply finished material around
the fixture housing cut-out.
Note: Finished hole diameter
must not exceed 5-1/2”
diameter. Ceiling materials
must not exceed 1-1/8” thick.
4. Remove fixture wire box cover
and appropriate knock-out to
connect flexible metal conduit to
wiring box with proper connector
(not supplied).
5. Connect supply wires to fixture
wires with proper size wire
nuts (not supplied), so as to
cover all bare current-carrying
conductors. Connect black
fixture wire to black (hot) power
supply wire, white fixture wire to
white (neutral) power suply wire,
and green fixture wire to green
(ground) wire.
6. Place all wiring and connections
back into wiring box and replace
cover.
Installation (Continued)
Black Thermal Protector
Lamp Socket
White
120V
5-1/2”
1-1/8” Max
Ceiling Thickness
A