SHANGHAI BAUDCOM COMMUNICATION DEVICE CO LTD
Website: www.baudcom.com.cn Email: info@baudcom.com.cn Tel: +86 21 37709251
OMI CONTROL:AGC:This parameter is used to indicate that the machine is on in AGC.
INPUT RF: For example, "INPUT RF: 82.0 dBuv", this parameter represents the online
level value of the local RF INPUT, which is related to the set value of channels. When
the number of channels corresponds to the actual level error of ±2dB, it is normal.
RF CHANNELS:If "RF CHANNELS: 60", this parameter represents the number of
CHANNELS after the machine is set.
LASER WAVE:For example, "LASER WAVE:1550.52nm", this parameter represents the
wavelength value of light after the machine is set, which has been set when the
product is released from the company.
4.4 Directions for use
This machine electricity before you should check whether the mains power supply
voltage is within the scope of 90 ~ 255 V (DC power supply - 48 V), the grounding
resistance of grounding line should be less than 4 Ω, RF input signal level is in the 75
~ 85 dbuv, and shielding network for voltage is close to zero volts. When meet the
above conditions can be POWER ON, then ENTER the "LASER POWER OFF"
LASER lock button switch for the OFF state, according to the LASER ON/OFF key,
then press ENTER to confirm, the LCD displays " BD-OP-SAT-15" said this machine
has entered the normal working state, such as panel Alarm red light flashing, said the
machine is a parameter is not in conformity with the conditions, such as RF signal no
input or small, the POWER 1 didn't open (with POWER 2), LASER current,
temperature overrun and so ON. At this point, press MENU to CHECK. If the suffix of
query parameter is "~", it means that the content parameter or fault item parameter
does not conform to it. If the single power supply 1 or 2 works, it will also appear
sound and light alarm. When the double power supply works, the content of this item
will no longer alarm, and the alarm will stop automatically after maintained for 1
minute, so as not to increase the noise source of the machine room.
5. WEB Management Function(optional)
The optional status monitoring transponder ensures compatibility with SCTE HMS
standards. Native RJ45 interface in the rear panel, or a PC or LAN connection
switches, the unit's IP address, subnet mask, the address of the server and installed