Bay Technical Associates DS4-RPC Manuale utente

OWNER'S MANUAL
________________
DS-RPC
DATA SWITCH/POWER CONTROL
FOR MODELS
DS2-RPC
DS4-RPC
Including the
DS71
DS71-MD2
DS74 &
DS73
Modules
BayTech Manual Publication #U140A124-01
August 1998

ii
Copyright 1998 by Bay Technical Associates, Inc.
BayTech, Telplex, LaserShare, Print Master and TRAN-X are
registered trademarks of Bay Technical Associates, Inc.
IBM, IBM PC, IBM PC/AT, IBM PC/XT are products and registered
trademarks of International Business Machines Corporation.
Hewlett-Packard LaserJet is a product and registered trademark of the
Hewlett-Packard Company.
PROCOMM PLUS is a product and registered trademark of Datastorm
Technologies, Inc.
Windows 95
is a product and registered trademark of Microsoft
Corporation.

DS-RPC OWNER’S MANUAL
ABOUT THIS OWNER’S MANUAL
__________________________________________________________________________________________
iii
ABOUT THIS OWNER’S MANUAL
This document provides information required for installing and operating
your Bay Tech equipment. It should allow the user to connect, power up,
and access an applications menu where peripheral equipment can be
controlled. We recommend reading this manual carefully, while placing
special emphasis on correct cabling and configuration. If you have any
problems with your installation, please contact a BayTech Applications
Engineer at 228-467-8231, call toll free from anywhere in the United
States using 1-800-523-2702 or contact us at our Web Site,
www.baytechdcd.com.
BayTech manufactures many remote site management products, data
switches, data collection multiplexers, remote power controllers, and
peripheral print sharers. If you would like information on any of these
products, please contact BayTech Customer Service at the numbers
previously listed.
Conventions used in this manual include:
CAUTION: This term is used to denote any condition that could
possibly result in physical harm to personnel or damage to
equipment.
IMPORTANT: This term is used to denote conditions that could
result in the loss of communications or to highlight the proper
functioning of equipment.
NOTE: This term is used to denote items of interest to the user.
<cr>: Carriage Return or ENTER

DS-RPC OWNER’S MANUAL
ABOUT THIS OWNER’S MANUAL
__________________________________________________________________________________________
iv
The information in this document is subject to change without notice. The
statements, configurations, technical data, and recommendations in this
document are believed to be accurate and reliable, but are presented
without express or implied warranty. Users must take full responsibility
for their applications of any products specified in this document. The
information in this document is proprietary to Bay Technical Associates,
Inc.
In the interest of improving internal design, operational function, and/or
reliability, Bay Technical Associates, Inc reserves the right to make
changes to the products described in this document without notice.
Bay Technical Associates, Inc does not assume any liability that may
occur due to the use or application of the product(s) or circuit layout(s)
described herein.
This manual replaces BayTech Publication U140A124.
We welcome any comments you may have about our products, and we
hope that you will continue to look to BayTech for your data
communication needs.

DS-RPC OWNER’S MANUAL
TABLE OF CONTENTS
__________________________________________________________________________________________
v
ABOUT THIS OWNER’S MANUAL iii
INTRODUCTION TO THE DS-RPC 1
PROGRAMMABLE FEATURES OF THE DS MODULES 3
DS-RPC QUICK START 6
EIA-232 SERIAL CONNECTION 6
OPERATION 6
DS-RPC CONFIGURATION 8
INSTALLATION 10
UNPACKING 10
PREPARING THE INSTALLATION SITE 11
POWER 11
POWER ON/OFF STATE 12
POWER UP SEQUENCE 12
CIRCUIT BREAKER 12
CABLING 13
RJ-45 CABLES AND ADAPTERS 13
MODEM CONNECTIONS 16
DETAILED OPERATION AND CONFIGURATION 18
CONNECTING TO THE DS-SERIES 18
EIA-232 SERIAL CONNECTION 18
INTERNAL MODEM CONNECTION DS71-MD2 (ONLY) 19
EXTERNAL MODEM CONNECTION 19
10BASE-T NETWORK PORT CONNECTION 20
OPERATION 21
ACCESSING MAIN MENU 21
SELECTING A DEVICE 23
PPP DIAL-UP CONNECTION 25
CONFIGURATION 26
DS71 OR DS71-MD2 CONFIGURATION 26
STATUS 27
SERIAL PORT CONFIGURATION 28
DS71 29

DS-RPC OWNER’S MANUAL
TABLE OF CONTENTS
__________________________________________________________________________________________
vi
DS71-MD2 31
PORT DEVICE NAME 34
PORT SELECT CODE 35
ATTENTION CHARACTER 36
DISCONNECT TIME GUARD 37
CONNECT PORT ID ECHO 38
LOGIN SETUP 39
HEADER 39
PASSWORD 40
MENU 41
AUTO CONNECT PORT 42
DCD LOGON/LOGOFF (DS71 ONLY) 44
LOCAL MODEM SETUP (DS71-MD2 ONLY) 45
RINGS TO ANSWER 46
MODEM TO MODEM XON/XOFF 46
CONNECTIVITY TIMEOUT 47
ESCAPE CHARACTER 48
UNIT ID 49
I/O MODULES RESET 49
UNIT RESET 49
MENU DRIVEN SELECTION 50
ACCESS CHARACTER STRING 50
DS74 CONFIGURATION 51
SERIAL PORT CONFIGURATION 52
PORT DEVICE NAME 52
DS73 CONFIGURATION 53
MODULE IP ADDRESS 54
DIAL-UP ADDRESS 55
SUBNET MASK 56
GATEWAY 57
PRIMARY DNS 58
SECONDARY DNS 58
PRIMARY NBNS 59
SECONDARY NBNS 59
USER NAME 60
PASSWORD 60
MODULE NAME 61
RPC OPERATION 62
ACCESSING MAIN MENU 62
CONTROLLING RECEPTACLES 63
RPC CONFIGURATION 64
CHANGE PASSWORD 65
DISABLING A PASSWORD 66
CHANGE OUTLET NAME 66
ENABLE/DISABLE CONFIRMATION 67
ENABLE/DISABLE STATUS MENU 67

DS-RPC OWNER’S MANUAL
TABLE OF CONTENTS
__________________________________________________________________________________________
vii
TECHNICAL SUPPORT 69
EQUIPMENT SETUP 70
REPACKAGING, SHIPPING AND RETURNING TO THE FACTORY
71
FCC RADIO FREQUENCY INTERFACE STATEMENT 72
APPENDIX A – SPECIFICATIONS 74
APPENDIX B – MODEM COMMANDS 76
APPENDIX C – WINDOWS 95 TUTORIAL 78
APPENDIX D – DRAWINGS 81
APPENDIX E – EPROM UPGRADE 89
APPENDIX F – ASCII CHARACTER DEFINITION 91
INDEX 92

DS-RPC OWNER’S MANUAL
INTRODUCTION TO THE DS-RPC
__________________________________________________________________________________________
1
INTRODUCTION TO THE DS-RPC
BayTech’s DS-RPC provides a single dialup or EIA-232 gateway to
multiple EIA-232 devices. Used for accessing remote equipment or simply
switching between multiple ports, the DS-RPC provides a full duplex
connection between the host and up to 12 peripherals. In a typical
application, the host module connects to a local or remote computer, and
the peripheral port modules connect to devices such as routers, hubs,
servers, and Data Service Units (DSU’s). The DS-RPC is also compatible
with other BayTech products including the Remote Power Control (RPC)
unit.

DS-RPC OWNER’S MANUAL
INTRODUCTION TO THE DS-RPC
__________________________________________________________________________________________
2
In a typical application, the host port of the data switch is connected to a
local or remote computer and the peripheral ports are connected to devices
such as routers, hubs, bar code readers, terminals, etc. Port selection is
accomplished two different ways.
(1) Use a simple menu-driven selection sequence or
(2) send an ASCII character string to select a port. The DS-RPC
also has four individual relay controlled, 115 VAC power
receptacles. Each receptacle is controlled by sending simple
commands from a local or remote location.
The DS2-RPC base unit consists of two slots for a host communications
module and a peripheral communications module. The DS4-RPC base unit
consists of four slots for a host communications module and up to three
peripheral communications modules. Both control the four power outlets,
LEDs, non-volatile storage, and data flow between connected modules. The
data bus is an internal matrix of high speed serial channels that allows
independent and simultaneous transmission of data between modules.
The DS71 host communications module is a system data controller that
directs operations between the base unit, system modules, and externally
connected devices. The DS71 provides primary user access for systems
communications. The DS71-MD2 has a high speed EIA-232 port and an
internal modem for remote or local data acquisition and control. The DS74
is a 4-port high speed EIA-232 peripheral communications module that
provides bi-directional communications between the host device and a
selected peripheral device connected to a DS74 port. The DS74 has
selectable serial configuration for baud rate, word size, stop bits, parity,
DTR, RTS inactive state and XON/XOFF handshaking for each port.

DS-RPC OWNER’S MANUAL
INTRODUCTION TO THE DS-RPC
__________________________________________________________________________________________
3
PROGRAMMABLE FEATURES OF THE DS MODULES
Highlighted features indicate items most often programmed
FEATURE DESCRIPTION ACTION PAGE
NO.
DS71 or DS71-MD2 HOST MODULE
Serial Port
Configuration Sets serial port speed of the DS71 and
DS71-MD2 Default = 9600, 8, 1, N,
Xon/Xoff Disabled
Enter baud rate, data bits,
stop bits, parity, and
Xon/Xoff
28
Port Device
Name Uniquely identifies the port (or device
connected to the port). Default = Host
EIA-232 and Host MODEM (DS71-
MD2 only)
Enter the device name 34
Port Select Code ASCII character string used to select a
port or module. Default = $BT Enter Port Select Code 35
Attention
Character A character sent in sequence five times
to invoke the main menu.
Default = ;
Enter Attention Character 36
Disconnect
Time Guard Provides reliable binary data
transmission. Default = Disabled Enable/Disable Disconnect
Time Guard 37
Port ID Echo Echoes the module number and port
number when you connect to the port.
Default = Disabled
Enable/Disable Connect Port
ID Echo 38
Header Unit information that appears upon login
Default = DS71 or DS71-MD2 Enable/Disable Header 39
Password Password protection for dial-up and
EIA-232 connections.
Default = Disabled
Enable/ Disable, and Program
Password 40
Menu Provides a menu interface for device
selection, and configuration.
Default = Enabled
Enable/Disable Menu 41
Auto Connect
Port Allows automatic connection to a
specified port upon dial-up or
EIA-232 connection.
Default = Disabled
Enable,/Disable, and Program
Auto Connect Port. 42
DCD
Logon/Logoff
(DS71 only)
External modem returns to logoff state
when DCD line goes low.
Default = Enabled
Enable/Disable menu
selection and make hardware
jumper change
44
Table 1
Questo manuale è adatto per i seguenti modelli
6
Indice
Altri manuali Bay Technical Associates Interruttore