SICK i17S Manuale utente

OPERATING INSTRUCTIONS
i17S
Safety switches

Described product
i17S
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is
only permissible within the limits of the legal determination of Copyright Law. Any modi‐
fication, abridgment or translation of this document is prohibited without the express
written permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
2O P E R A T I N G I N S T R U C T I O N S | i17S 8027215/1CY3/2022-10-24 | SICK
Subject to change without notice

Contents
1 Scope.................................................................................................. 4
2 On safety............................................................................................. 5
2.1 Qualified safety personnel....................................................................... 5
2.2 Applications of the safety switches......................................................... 5
2.3 Correct use................................................................................................ 6
2.4 General safety notes and protective measures...................................... 6
3 Mounting............................................................................................. 7
3.1 Reversing the actuating direction............................................................ 8
3.2 Protection against surroundings.............................................................. 9
4 Electrical installation........................................................................ 10
4.1 Variants with M20 cable entry................................................................. 10
4.2 Variants with M12 plug connector........................................................... 10
5 Commissioning.................................................................................. 11
5.1 Tests before the initial commissioning.................................................... 11
5.2 Periodic technical inspections................................................................. 11
6 Disposal.............................................................................................. 12
7 Technical specifications................................................................... 13
7.1 General system data................................................................................ 13
7.2 Dimensional drawings.............................................................................. 13
7.3 Minimum door radius............................................................................... 16
8 Conformities and certificates.......................................................... 17
8.1 EU declaration of conformity.................................................................... 17
8.2 UK declaration of conformity................................................................... 17
CONTENTS
8027215/1CY3/2022-10-24 | SICK O P E R A T I N G I N S T R U C T I O N S | i17S 3
Subject to change without notice

1 Scope
These operating instructions are applicable to the i17S safety switch.
These operating instructions are original operating instructions.
1 SCOPE
4O P E R A T I N G I N S T R U C T I O N S | i17S 8027215/1CY3/2022-10-24 | SICK
Subject to change without notice

2 On safety
This chapter deals with your own safety and the safety of the equipment operators.
bPlease read this chapter carefully before working with the i17S or with the
machine protected by the i17S.
The national/international rules and regulations apply to the installation, commission‐
ing, use and periodic technical inspections of the safety switches, in particular
•the Machinery Directive,
•the Low Voltage Directive,
•the Work Equipment Directive,
•the safety regulations as well as
•the work safety regulations/safety rules.
Manufacturers and operators of the machine on which the protective devices are used
are responsible for obtaining and observing all applicable safety regulations and rules.
2.1 Qualified safety personnel
The i17S safety switch must be mounted, installed and commissioned only by qualified
safety personnel. Qualified safety personnel are defined as persons who
•have undergone the appropriate technical training
and
•have been instructed by the responsible machine owner in the operation of the
machine and the current valid safety guidelines
and
•who have access to these operating instructions.
2.2 Applications of the safety switches
Safety switches of the i17S series are electromagnetic switching devices.
They secure moving protective devices with a guard function so that
•the dangerous state of the machine can only be switched on when the guard is
closed,
•a STOP command is triggered if the protective device is opened while the machine
is operating.
For the control this means that
•activation commands that cause dangerous conditions, may only become active
when the guard is in the protective position and the dangerous conditions have
been terminated before the protective position is cancelled.
Prior to the use of safety switches, a risk assessment must be performed on the
machine.
WARNING
If the safety switches are connected in series the Performance Level (PL) may be
reduced due to reduced fault detection, depending on the application (ISO/TR 24119).
ON SAFETY 2
8027215/1CY3/2022-10-24 | SICK O P E R A T I N G I N S T R U C T I O N S | i17S 5
Subject to change without notice

2.3 Correct use
The i17S safety switch must be used only as defined in section 2.2 “Applications of
the safety switches”.The safety switch must be used only on the machine where it has
been mounted, installed and initialized by qualified safety personnel in accordance with
these operating instructions.
The product may be used in safety functions.
All warranty claims against SICK AG are forfeited in the case of any other use, or
alterations being made to the safety switch, even as part of its mounting or installation.
Correct use includes the regular inspection of the protective device by qualified safety
personnel in accordance with section 5.2.
2.4 General safety notes and protective measures
Safety switches provide a protection function for persons. Incorrect installation or
manipulation can result in serious injuries.
WARNING
Safety switches are not allowed to be bypassed, turned away, removed or made ineffec‐
tive in any other manner. Take measures to reduce bypassing options as necessary.
Observe EN ISO 14119 for using interlocking devices associated with physical guards.
WARNING
The switching procedure may only be activated by actuators specifically designated for
that purpose, which are connected to the protective device in such a manner that they
cannot be detached.
Restrict access to replacement actuators, so they cannot be used for bypassing.
2 ON SAFETY
6O P E R A T I N G I N S T R U C T I O N S | i17S 8027215/1CY3/2022-10-24 | SICK
Subject to change without notice

3 Mounting
WARNING
Mounting is only allowed to be performed by qualified safety personnel.
bObserve EN ISO 14119 for using interlocking devices associated with physical
guards.
Fit the safety switches such that
•it is difficult for operators to access when the protective device is open,
•it is possible to inspect and replace the safety switches.
NOTICE
Safety switches and actuators must not be used as a mechanical stop.
2 x M5 CSK
3 x M20
2 x M5
2 x M5
1,4 N m
12.39 lb in
IP67
Figure 1: Monting safety switch
2mm
Figure 2: Mounting
bMount the safety switch positively.
bTighten the safety switch using 2 × M5 screws to 1.4Nm (see figure 1).
bTo fix the safety switch, fit additional dowel pins.
bConnect the actuator to the protective device durably and non-detatchably, e.g.
using one-way bolts or by riveting or welding.
bFit an additional stop for moving parts of the guard (see figure 2).
bInsert the actuator into the actuating head.
MOUNTING 3
8027215/1CY3/2022-10-24 | SICK O P E R A T I N G I N S T R U C T I O N S | i17S 7
Subject to change without notice

3.1 Reversing the actuating direction
4
1
8
180
1,2 N m
(10.62 lb in)
Figure 3: Reversing the actuating direction
bInsert the actuator.
bUndo the cover screws.
bRelease catch on the actuating head.
bRotate head by 180°.
bEngage.
bTighten the cover screws.
bSeal unused actuating slots with the enclosed slot covers.
3 MOUNTING
8O P E R A T I N G I N S T R U C T I O N S | i17S 8027215/1CY3/2022-10-24 | SICK
Subject to change without notice

50 N
Figure 4: Mounting the catch and retainer kit iE16- SCR, only in conjunction with actuator
iE16-S1
Figure 5: Mounting the alignment aid with actuator iE16-F1 or iE16-F2
3.2 Protection against surroundings
A precondition for a durable and perfect safety function is the protection of the
actuating head against penetration by foreign matter such as shavings, sand, abrasive
materials etc.
Cover the control slot, the actuator and the type label when painting.
MOUNTING 3
8027215/1CY3/2022-10-24 | SICK O P E R A T I N G I N S T R U C T I O N S | i17S 9
Subject to change without notice

4 Electrical installation
WARNING
The electrical connection is only allowed to be made by qualified safety personnel.
4.1 Variants with M20 cable entry
i17-SA213
bBreak open the desired opening.
bFit the M20 cable gland with the corresponding enclosure rating.
bContact assignments see figure 6, page 10.
bOperate all contact pairs in the same voltage range.
bConnect all live parts to one side of the contact block.
20
11
Inserted
actuator
Extended
actuator
Figure 6: Switching elements and switching functions for variants with M20 cable entry
bTighten the clamping bolts to 1.0Nm.
bEnsure the cable entry is leak-proof.
bClose and screw switch cover in place.
bTighten screw to 1.2 Nm.
4.2 Variants with M12 plug connector
i17-SA214
1
11
21 22
34
33
12
1
14
3 3
11 12
22
3433
21
Figure 7: Contact assignments i17-SA214
4 ELECTRICAL INSTALLATION
10 O P E R A T I N G I N S T R U C T I O N S | i17S 8027215/1CY3/2022-10-24 | SICK
Subject to change without notice
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali SICK Interruttore

SICK
SICK TBS Manuale utente

SICK
SICK SENSICK WT 36 Manuale utente

SICK
SICK ES11-SA1A4 Manuale utente

SICK
SICK i150RP Manuale utente

SICK
SICK i110RP Manuale utente

SICK
SICK RE300 Manuale utente

SICK
SICK L25 Manuale utente

SICK
SICK ES21 M12 contact Manuale utente

SICK
SICK IN4000 Standard Manuale utente

SICK
SICK NAMUR IM08 N ZWO Series Manuale utente

SICK
SICK PAC50 Manuale utente

SICK
SICK RE1 Manuale utente

SICK
SICK IME2S Manuale utente

SICK
SICK RE1 Manuale utente

SICK
SICK ES21 Manuale utente

SICK
SICK IN4000 Direct Manuale utente

SICK
SICK TR4 Manuale utente

SICK
SICK TR4 Manuale utente

SICK
SICK STR1 Manuale utente

SICK
SICK T4000 Direct Unicode Manuale utente