red LED green LED Fault Remedy
not
illuminated
continuously
lit
Radar tripping when door is closing 1. Set angle of radar further away from the door.
2. Adjust radar eld size.
Radar false tripping without
apparent external inuence
1. Avoid light sources (e.g. uorescent tubes) in the immediate vicinity of the detector.
2. No moving objects (plants, advertising posters, etc.) in the vicinity of the detector.
3. Avoid strong vibration at the radar detector
4. Possible inuence from a second radar detector in the vicinity (very unlikely)
continuously
lit
not
illuminated
AIR tripping when door is closing 1. Set angle of AIR detector further away from the door
AIR false tripping without apparent
external inuence
1. Avoid light sources (e.g. uorescent tubes) in the immediate vicinity of the detector.
2. Avoid puddles of water on the ground.
3. Avoid strong vibration at the AIR detector.
4. Inuence of overlapping AIR eld from another detector.
Set new Reglobeam address or CAN bus address.
5. Reduce sensitivity of the AIR (increase value).
not
illuminated
not
illuminated Door stays open 1. Switch AIR exit contact logic to other value
7Remedying malfunctions
8Technical data
7.1 Remedying false tripping
7.2 Remedying detector malfunctions
red LED green LED Fault Remedy
ashing ashing
1
1: Self test (RAM/ROM)
2: Watchdog
1. Disconnect device from supply voltage
2. Restart device
3. If device displays fault again or does not start ➔renew device
ashing not
illuminated
2
5: AIR fault
6: AIR output fault
1. Disconnect device from supply voltage
2. Clean optics-cover and check for scratches
3. Restart device
4. If device displays fault again or does not start ➔renew device
Technology Active infrared (wavelength: 880nm), radar double eld module ➔ PrimeTec (24.125 GHz)
Number of IR spots 24
IR spot dimensions 3 cm x 3 cm (at 2.2 m mounting height)
Response time < 200 ms
Mounting height 1.8 - 4 m
Angle setting of IR spots – 5° ... + 7° continuously adjustable
Power Supply ≤ 120 mA @ 11.5 ... 32 VDC
Power consumption < 4 Watt
Making current ≤ 240 mA
Output (AIR / Radar) Semiconductor relay: max. contact voltage 24 VAC / 34 VDC, max. contact resistance: 10 Ω
max. load current 40 mA, max switching capacity:
500 mW (AC) / 500 mW (DC)
Protection type Suitable for use acc. to IP54
Operating temperature -20° ... 60° C
Dimensionsn PrimeTec: 260 x 60 x 48.5mm (LxWxD), PrimeScan: 216 x 60 x 47.5mm (LxWxD)
Weight PrimeTec: 250g, PrimeScan: 180g
Estimated economic life-time 20 years
9EU Declaration of Conformity
10 WEEE
11 FCC approval
12 Contact
This device meets the requirements of Part 15 of the FCC regulations and the RSS-210 standard of Industry Canada.
Warning: Changes or modications made to this device may void the FCC authorisation to operate this device.
See attachment
Devices with this symbol must be treated separately during disposal. This must be done in accordance with the laws of the
respective countries for environmentally sound disposal, processing and recycling of electrical and electronic equipment.