Useful information
CHECK the integrity of the unit after having removed it from the box.
Check that the data written on the box correspond to the type of gas used.
When doing the electrical connections, follow the drawing closely.
Any use of the detector for purposes other than the intended one is considered improper,
and as a result of which BEINAT S.r.l. therefore disclaims any responsibility for possible
damages caused to people, animals or objects.
TERMS and EXPECTATIONS: The installation of the switch , its ordinary and extraordinary
maintenance, every six months, and its out of service removal at the end of the functional
life guaranteed by the manufacturer, must be carried out by authorized or specialized personnel.
In order to achieve long and satisfactory use of your switch, use it by respecting the following precautions.
Do not drop it.
Heavy knocks or falls during transportation or installation can damage the appliance.
Avoid abrupt temperature fluctuations.
Sudden temperature variations can cause condensation and the detector could work poorly and could become
very sensitive, and generate false alarms.
Do not allow it to become wet.
The control unit can be seriously damaged as it is not waterproof either when immersed in water or exposed
to high levels of humidity.
Cleaning
Never clean the device with chemical products. If necessary, wash with a moist cloth.
SL600
ILDA100
SL200 Sliders 1 "1/4
SL600 Slider 1/8
SL150 Stem in stainless inox
PL150 Prolongs Stem in stainless inox
Antifloodingprobe
Probes Adaptable for Functioning
Power Supply ....................................................................................................... 230/240 VAC ±10%
Power demand ............................................................................................................. 1 W @230 VAC
Insulation ......................................................................................................................... Class II
Power Supply ................................................................................................................ 12 VDC ±10%
Power demand ............................................................................................................... 1 W @24 VDC
Range of contacts ................................................................................................... 10A 250V resistive
Max distance between probe and control unit ................................................................................. 100 m
Section connecting cables probe .................................................................................................. 1 mm
Connection: The cable of connection of the probe must not be installed together with the power
cables.
Operating Temperature ..................................................................................... from -10° C to + 60° C
Min and Max operating Humidity ................................................................................. lower than 95% RH
Body Material probe ........................................................................................... self extinguishing plastic
Degree of protection ...................................................................................................... IP20 in the air
Omega-type size DIN EN 50092 3 modules ................................................................................... 52*90*52
mounting: ........................................................................................................................... electric board
Electromagnetic Compatibility "CE"........................................................According to Reference EN regulations
Technical Specifications