BIFFI OLGA-H Manuale utente

Installation, Operation and Maintenance Manual
MAN 607 Rev. 6
February 2022
Bif OLGA-H
High Pressure Double-Acting Hydraulic Actuator
Copyright © Bif. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website www.bif.it or from your nearest Bif Center:
Bif Italia s.r.l. - Strada Bif 165, 29017 Fiorenzuola d'Arda (PC) – Italy PH: +39 0523 944 411 – bif_italia@bif.it

February 2022
Installation, Operation and Maintenance Manual
MAN 607 Rev. 6
Revision Details
Revision Details
Revision Details
Rev. Date Description Prepared Checked Approved
6 February 2022 General update (Migration to new template)
5 April 2018 Updated data plate Ermanni Oreci Vigliano
4 April 2016 Updated applicable regulation (chapter 1.1.1) Ermanni Oreci Vigliano
3February 2013 Updated chapter 5.1.1 Ermanni Stoto Vigliano
2July 2012 General update Ermanni Stoto Vigliano
1 November 2010 General update Ermanni Stoto Vigliano
0May 1999 Document release Lazzarini Aliani Ziveri

i
Table of ContentsInstallation, Operation and Maintenance Manual
MAN 607 Rev. 6 February 2022
Table of Contents
Table of Contents
Section 1: General Warnings
1.1 Generalities................................................................................................... 1
1.1.1 Applicable Regulation ........................................................................ 1
1.1.2 Terms and Conditions......................................................................... 1
1.2 Identication Plate ........................................................................................ 2
1.3 Introducing the Actuator............................................................................... 2
1.4 Data Sheet .................................................................................................... 3
Section 2: Installation
2.1 Checks upon Actuator Receipt.......................................................................... 4
2.2 Actuator Handling......................................................................................... 4
2.3 Storage ......................................................................................................... 8
2.4 Actuator Assembly on the Valve.................................................................... 8
2.4.1 Types of Assembly.............................................................................. 8
2.4.2 Assembly Procedure......................................................................... 10
2.5 Hydraulic Connections................................................................................ 11
2.6 Electrical Connections (If Any)..................................................................... 12
2.7 Commissioning........................................................................................... 13
Section 3: Operation and Use
3.1 Operation Description................................................................................. 14
3.2 Residual Risks.............................................................................................. 15
3.3 Operations.................................................................................................. 15
3.3.1 Local Manual Operation ....................................................................15
3.3.2 Emergency Manual Operation by MHP ............................................. 17
3.3.3 Emergency Manual Operation by MSJ-MHW .....................................18
3.4 Calibration of the Angular Stroke ................................................................ 18
3.5 Calibration of Microswitches (Bif Limit Switch Box Only)............................ 23
3.6 Calibration of the Operation Time .............................................................. 25
Section 4: Operational Tests and Inspections
Operational Tests and Inspections......................................................................... 27

ii
February 2022
Installation, Operation and Maintenance Manual
MAN 607 Rev. 6
Table of Contents
Table of Contents
Section 5: Maintenance
5.1 Periodic Maintenance.................................................................................. 28
5.2 Extraodinary Maintenance .......................................................................... 32
5.2.1 Replacement of High Pressure Cylinder Seals .................................... 32
5.2.2 Replacement of Seals for Actuators with Bif Manual Handpump ..... 36
5.3 Lubrication of Mechanism........................................................................... 40
5.4 Dismantling and Demolition ....................................................................... 41
Section 6: Troubleshooting
6.1 Failure or Breakdown Research.................................................................... 42
Section 7: Layouts
7.1 Spare Parts Order........................................................................................ 43
7.2 Parts List for Maintenance and Replacing Procedure ................................... 44
Section 8: Date Report for Maintenance Operations
Date Report for Maintenance Operations .............................................................. 52

1
Installation, Operation and Maintenance Manual
MAN 607 Rev. 6 February 2022
General Warnings
Section 1: General Warnings
Section 1: General Warnings
NOTICE
The manual is an integral part of the machine, it should be carefully read before carrying
out any operation and it should be kept for future references.
1.1 Generalities
Bif Italia s.r.l. actuators are conceived, manufactured and controlled according to the
Quality Control System in compliance with EN-ISO 9001 international regulation.
1.1.1 Applicable Regulation
EN ISO 12100:2010: Safety of machinery – General principles for design – Risk
assessment and risk reduction
2006/42/EC: Machine directive
2014/68/EU: Directive for pressure PED equipment
2014/35/EU: Directive for low voltage equipment
2014/30/EU: Directive for the electromagnetic compatibility
2014/34/EU: Directive and safety instructions for use in hazardous area
NOTICE
Bif Italia s.r.l. pays the highest attention to collecting and verifying the documentation
contained in this Installation, Operation and Maintenance Manual. However, Bif Italia
s.r.l. is not liable for any mistakes contained in this manual and for damage or accidents
due to the use of the latter. The information contained is of exclusive reserved ownership
of Bif Italia s.r.l. and may be modied without prior notice. All rights reserved.
1.1.2 Terms and Conditions
Bif Italia s.r.l. guarantees that all the items produced are free of defects in workmanship
and manufacturing materials and meet relevant current specications, provided they
are installed, used and serviced according to the instructions contained in the present
manual. The warranty can last either one year from the date of installation by the initial
user of the product, or eighteen months from the date of shipment to the initial user,
depending on which event occurs rst. All detailed warranty conditions are specied in
the documentation forwarded together with the product. This warranty does not cover
special products or components not warranted by subcontractors, or materials that were
used or installed improperly or were modied or repaired by unauthorized staff. In the
event that a fault condition be caused by improper installation, maintenance or use, or by
irregular working conditions, the repairs will be charged according to applicable fees.
The warranty and Bif Italia s.r.l. liability shall lapse in the event that any modication
or tampering whatsoever be performed on the actuator.

2
February 2022
Installation, Operation and Maintenance Manual
MAN 607 Rev. 6
Section 1: General Warnings
General Warnings
1.2 Identication Plate
! WARNING
It is forbidden to modify the information and the marks without previous written
authorization by Bif Italia s.r.l.
The plate fastened on the actuator contains the following information (Figure1).
Figure 1 Data plate
1.3 Introducing the Actuator
The hydraulic actuator series OLGA-H was engineered and is manufactured to provide
maximum torque output with minimum supply pressure. The OLGA-H actuators are
suitable for any quarter turn application such as ball, plug, buttery valves or dampers, in
both On-Off and Modulating heavy-duty service.
The actuator (see Figure 2) is made up of a weatherproof scotch yoke mechanism
transforming the linear movement of the pneumatic cylinder (on closing or opening) into
the rotary movement, which is necessary for operation. The angular stroke of the yoke is
adjustable between 82° and 98° by means of the external mechanical stops screwed into the
left wall of the mechanism housing and into the end ange of the pneumatic cylinder. The
cover of the scotch yoke mechanism is arranged for the assembly of the required accessories
(positioner, signalling limit switches, position transducer, etc.) by means of proper matching
units. The above mentioned accessories are operated by the actuator drive sleeve. The
housing of the scotch yoke mechanism has a ange with threaded holes to x the actuator
to the valve either directly or, if required, with the interposition of an adaptor ange or a
mounting bracket. The actuator yoke has a hole with keyways suitable for the assembly
of an insert bush the internal hole of which is machined (by Bif or at Customer's care),
according to the shape and dimensions of the valve stem. Bif can supply different types of
control system following customer's requirements.
The expected lifetime of actuator is approximately 25 years.

3
Installation, Operation and Maintenance Manual
MAN 607 Rev. 6 February 2022
General Warnings
Section 1: General Warnings
General Warnings
High pressureHigh pressure
control valvecontrol valve
enclosure (optional)enclosure (optional)
Valve positionValve position
indicatorindicator
Hydraulic cylinderHydraulic cylinder
Optional forOptional for
OLGA-H-MHPOLGA-H-MHP
models or second models or second
pneumatic cylinder for pneumatic cylinder for
"double cylinders" models"double cylinders" models
HydraulicHydraulic
cylindercylinder
Scotch yoke Scotch yoke
mechanismmechanism
Figure 2 Identication of actuator parts
1.4 Data Sheet
Supply uid Hydraulic oil, special version for re-resistant uids
Operating temperature Standard: from –30 °C to +100 °C
Optional: from –60 °C to +140 °C
Supply pressure Please refer to technical document:
“actuator data sheet”
ManualManual
handpump handpump
(optional)(optional)

4
February 2022
Installation, Operation and Maintenance Manual
MAN 607 Rev. 6
Section 2: Installation
Installation
Section 2: Installation
2.1
Checks upon Actuator Receipt
• Check that the model, the serial number of the actuator and the technical data
reported on the identication plate correspond with those of order conrmation,
refer to Section 1.2.
• Check that the actuator is equipped with the ttings as provided for by
order conrmation.
• Check that the actuator was not damaged during transportation: if necessary,
renovate the painting according to the specication reported on the
order conrmation.
• If the actuator is received already assembled with the valve, its settings have
already been made.
• If the actuator is delivered separately from the valve, it is necessary to check, and,
if required, to adjust, the settings of the mechanical stops (Section 3.4), and of
microswitches (if any) (Section 3.5).
2.2 Actuator Handling
NOTICE
The lifting and handling of the actuator must be done by qualied personnel and in accordance
with the laws and regulations in force. Avoid the lifted actuator to be hung above the personnel.
! WARNING
The actuator must be lifted by means of a suitable lifting apparatus. The weight of the
actuators is indicated in the technical documentation attached to the equipment itself.
! WARNING
For lifting and moving the actuator, use only hooks tted with safety latch, like the one, for
example, shown in Figure 3.
Figure 3 Example of hook with safety latch

5
Installation, Operation and Maintenance Manual
MAN 607 Rev. 6 February 2022
Section 2: Installation
Installation
Figure 4 Lifting points for OLGA-H / OLGA-H MHP / OLGA-H MSJ
1-2 = lifting points (obligatory)
3= balancing point
Figure 5
1 = point of support
2 = supports for lateral positioning
! WARNING
3 = don’t lay the actuator on tie-rods of cylinder/s and don’t lay the actuator on accessories
(manual override, pneumatic control group, etc.).

6
February 2022
Installation, Operation and Maintenance Manual
MAN 607 Rev. 6
Section 2: Installation
Installation
Figure 6
BIFFI ITALIA
LIFTING LUGS TO BE USED FOR THE
ACTUATOR ONLY. DO NOT LIFT VALVE AND
ACTUATOR TOGETHER.
DO NOT DISASSEMBLE TOP OR
BOTTOM COVER.
SPRING LOADED.
POTENTIAL ELECTROSTATIC CHARGE
HAZARD
BIFFI IS NOT LIABLE FOR ANY PERSONNEL
INJURY DUE TO INCORRECT USE
REFER TO IOM
• For lifting unbalanced loads, use ropes of different lengths or chains with
adjustable length.
• Check each time the conditions of all lifting equipment used and discard it if
not in perfect working order.
• Do not knot or twist the ropes so as not to reduce the lifting capacity or
produce torsional effects on the load being lifted.
• Use the utmost caution and remain at a safe distance from lifted actuator
unless absolutely necessary; do not stand or pass under suspended loads.
• Pay attention in putting under tension the ropes to prevent the load shifting
sideways in an uncontrolled manner.
• Use slings of such length that the angles of the leg from vertical are as narrow
as possible (αMAX < 20°).
• During handling, do not transport the suspended actuator above staff
members in charge of the operation.
! WARNING
Do not use the lifting eyelets on actuator to lift valve + actuator assembly.
Altri manuali per OLGA-H
2
Indice
Altri manuali BIFFI Controllori

BIFFI
BIFFI OLGA-H Manuale utente

BIFFI
BIFFI OLGAS-H Manuale utente

BIFFI
BIFFI HLRA Manuale utente

BIFFI
BIFFI RPD Series Manuale utente

BIFFI
BIFFI OLGA Series Manuale utente

BIFFI
BIFFI HLA Manuale utente

BIFFI
BIFFI GIGS 0.3 Manuale utente

BIFFI
BIFFI TPS Series Manuale utente

BIFFI
BIFFI ALGA Series Manuale utente
BIFFI
BIFFI ICON3000 Series Guida all'installazione

BIFFI
BIFFI ALGAS-QA Series Manuale

BIFFI
BIFFI OLGA Manuale utente

BIFFI
BIFFI GPO-EAC Manuale utente

BIFFI
BIFFI ECU 1000 Manuale

BIFFI
BIFFI FCB Series Manuale utente

BIFFI
BIFFI F02 Manuale

BIFFI
BIFFI ALGAS-QA EAC Manuale utente

BIFFI
BIFFI HLAS Manuale utente

BIFFI
BIFFI HLAS Manuale utente

BIFFI
BIFFI GIG Manuale utente