Technical Specications
Item Category Performance Data
Operating Voltage 220 - 240Vac, 50-60 Hz, 1200 WATTS
Warm Air Speed Output 150 m/s
Display LCD instructions and countdown
Motor Type 35,000 rpm, 2 speed adjustable
Motor Thermal Protection Auto Resetting Thermostat turns unit o, 240V at 239°F (115°C)
Noise Level 80db (A) 1 metre
Water Tank LED indicator when tank is full
Filter Sensor LED indicator when lter is full
Air Purication Enzyme HEPA Filter H13 - simple cartridge replacement system
Air Freshener Bioger: moisturiser, sanitizer, air freshener
Water Tank & Filter Security Sliding locking system, lock both with one touch
Drying Time Less than 10 seconds
Circuit Operation Infared Automatic, self adjusting
Timing Protection 20 seconds auto shut o
Drip Proof IP33
Isolation CLASS 11
Certicates CE, GGS, ETL, WEEE
Net Weight 9 kg
Shipping Weight 10 kg
Unit Size 330mm W x 660mm H x 230mm D
Item Code Cover Type/Finish
BE1000W Fire proof ABS, 94VO, PC, PMMA, UV Coated
BE1000S Fire proof ABS, 94VO, PC, PMMA, UV Coated
BE1000B Fire proof ABS, 94VO, PC, PMMA, UV Coated
BE1000G Fire proof ABS, 94VO, PC, PMMA, UV Coated
Operating Instructions and Parts Manual
Surface Mounted High Speed Hand Dryer
Executive
1Executive 2
General Safety Information
This product is intended for installation by a
qualied service person. Use AWAG No.16 solid
conductor for wiring.
Failure to properly ground unit could result in
electrical shock and/or death.
Disconnect power at the service breaker before
installing or servicing.
NOT FOR HOUSEHOLD USE - MAY CAUSE BURNS
“IMPROPRE A L’USAGE DOMESTIQUE - PUET
OCCASIONNER.”
• WARNING NOTE: Do not install dryer over wash basin.
Type Y attachment
If the power supply cord is damaged, it must be
replaced by the manufacturer or its service agent or a
similar qualied person in order to avoid a hazard.
Means for disconnection must be incorporated in the
xed wiring in accordance with the wiring rules.
Installation
1. Make sure power supply breaker is switched o.
Installation must be carried out in accordance with the
current edition of the local wiring regulations code
having jurisdiction. Installation should be performed
only by a qualied electrician.
2. Place template against wall at desired height
(see mounting height recommendations) and mark
locations of 4 mounting holes and wire service entry at
knockout (KO) location.
NOTE: For two or more dryers, dryers should be no
closer than 24 inches (610 mm) on centre.
4. Connect supply wires to terminal block where
indicated and connect ground wire to baseplate with
ground screw.
Connections:
A Type: Power cable not equipped
1. Secure the line and connect the power cable into the
proper terminal block locations. Verify connections are
correct before proceding.
2. Cover the power connector with the provided
housing cover (Power Supply Cover Kit)
Minimum wire cross section: 2x1mm
B Type: Power cabe equipped
330mm 230mm
660mm