Blade RackSwitch G8052 Manuale utente

2051 Mission College Blvd.
Santa Clara, CA 95054
www.bladenetwork.net
RackSwitch™G8052
Installation Guide
Part Number: BPP-00038-00, September 2010

RackSwitch G8052 Installation
2BPP-00038-00, September 2010
Copyright © 2010 BLADE Network Technologies, Inc., 2051 Mission College Blvd., Santa Clara,
California, 95054, USA. All rights reserved. Part Number: BPP-00038-00.
This document is protected by copyright and distributed under licenses restricting its use, copying,
distribution, and decompilation. No part of this document may be reproduced in any form by any
means without prior written authorization of BLADE Network Technologies, Inc. Documentation is
provided “as is” without warranty of any kind, either express or implied, including any kind of
implied or express warranty of non-infringement or the implied warranties of merchantability or
fitness for a particular purpose.
U.S. Government End Users: This document is provided with a “commercial item” as defined by FAR
2.101 (Oct. 1995) and contains “commercial technical data” and “commercial software
documentation” as those terms are used in FAR 12.211-12.212 (Oct. 1995). Government End Users
are authorized to use this documentation only in accordance with those rights and restrictions set forth
herein, consistent with FAR 12.211- 12.212 (Oct. 1995), DFARS 227.7202 (JUN 1995) and DFARS
252.227-7015 (Nov. 1995).
BLADE Network Technologies, Inc. reserves the right to change any products described herein at any
time, and without notice. BLADE Network Technologies, Inc. assumes no responsibility or liability
arising from the use of products described herein, except as expressly agreed to in writing by BLADE
Network Technologies, Inc. The use and purchase of this product does not convey a license under any
patent rights, trademark rights, or any other intellectual property rights of BLADE Network
Technologies, Inc.
BLADE Network Technologies, the BLADE logo, BLADEHarmony, BNT, NMotion, RackSwitch,
Rackonomics, RackSwitch Solution Partner, ServerMobility, SmartConnect and VMready are
trademarks of BLADE Network Technologies. All other names or marks are property of their
respective owners.
Originated in the USA.

RackSwitch G8052 Installation
BPP-00038-00, September 2010 Contents 3
Contents
Preface 5
Who Should Use This Book 5
Related Documentation 5
How to Get Help 6
Chapter 1: RackSwitch G8052 Description and Specifications 7
RackSwitch G8052 Features 7
Switch Components 9
Hardware Options 9
Switch Unit 9
Switch Ports 12
Switch LEDs 15
Technical Specifications 17
Physical Characteristics 17
Environmental Specifications 17
Power Specifications 18
Ordering Information 19
Chapter 2: Installing the RackSwitch G8052 21
Required Tools 21
Package Contents 21
Environmental Requirements 22
Preventing Electric Shock 22
Preventing Electrostatic Discharge 23
Installing the RackSwitch G8052 in a Standard Equipment Rack 24
Installing the RackSwitch G8052 in a 4-Post Rack 27
Installing the RackSwitch G8052 in an iDataPlex Rack 32
Installing the RackSwitch G8052 in a System X Rack 35
Initializing the RackSwitch G8052 40
Default Configuration 41
Configuring an IP Interface 41
Using the Boot Management Menu 43
Installing an SFP/SFP+ Transceiver 44
SFP Optical Transceiver 44
SFP Copper Transceiver 45
SFP+ Optical Transceiver 46

RackSwitch G8052 Installation
4Contents BPP-00038-00, September 2010
Installing or Replacing a Power Supply Module 47
Removing an AC Power Supply Module 47
Installing an AC Power Supply Module 48
Installing or Replacing a Fan Module 49
Removing a Fan Module 49
Installing a Fan Module 49
Troubleshooting 51
System LEDs Do Not Light 51
Port link LED Does Not Light 51
Temperature Sensor Warning 51
Switch Does Not Initialize (Boot) 52
Appendix A: Safety and Compliance Statements 53
Safety Messages 53
Compliance Statements 58

BPP-00038-00, September 2010 5
Preface
This Installation Guide provides information and instructions for installing a Blade Network
Technologies RackSwitch G8052. For information about configuration and management of the
switch, refer to your Command Reference and the product release notes.
Who Should Use This Book
This Installation Guide is intended for network installers and system administrators engaged
in configuring and maintaining a network. It assumes that you are familiar with your
RackSwitch G8052, your Web browser, Ethernet concepts, IP addressing, the IEEE 802.1D
Spanning Tree Protocol, and SNMP configuration parameters.
Related Documentation
For documentation about configuring your switch, see the RackSwitch G8052 Application Guide
and Command Reference.
For details about the switch information, statistics, and configuration parameters, see the
RackSwitch G8052 Command Reference.

RackSwitch G8052 Installation
6BPP-00038-00, September 2010
How to Get Help
If you need help, service, or technical assistance, call Blade Network Technologies Technical
Support:
US toll free calls: 1-800-414-5268
International calls: 1-408-834-7871
You also can visit our web site at the following address:
http://www.bladenetwork.net
Click the Support tab.
The warranty card received with your product provides details for contacting a customer
support representative. If you are unable to locate this information, please contact your reseller.
Before you call, prepare the following information:
Serial number of the switch unit
Software release version number
Brief description of the problem and the steps you have already taken
Technical support dump information (# show tech-support)
Note – In case of any suspected hardware related defect, immediately call the BLADE
support line to get the issue resolved. There are no field serviceable parts inside the enclosure and
tampering with internal components in an attempt to diagnose hardware or fix defects will void the
warranty and the product will be repaired at the customer’s expense.

BPP-00038-00, September 2010 7
CHAPTER 1
RackSwitch G8052
Description and Specifications
The RackSwitch G8052 is a rackable aggregation switch with unmatched line-rate Layer 2/3
performance. The G8052 uses a wire-speed, non-blocking switching fabric that provides
simultaneous wire-speed transport of multiple packets at low latency on all ports.
The G8052 contains 10/100/1000BaseT Ethernet ports and four 10GbE SFP+ ports. The SFP+ slots
can be populated with optical or copper transceivers.
This 1U switch is rack mountable in either the horizontal or vertical direction, depending on your
application.
You can manage the switch through the console port, or through a network connection using Telnet,
a Web browser-based interface, or SNMP-based network management software.
RackSwitch G8052 Features
This section provides an overview of RackSwitch G8052 features.
Performance
176 Gbps throughput (full duplex), non-blocking switching architecture
100% line rate
Deterministic port-to-port latency under 2 microseconds with 64B packets
Management Features
Clients
Industry standard command-line interface (ISCLI)
Browser-based Interface (BBI)
BladeHarmony Manager

RackSwitch G8052 Installation
8Chapter 1: RackSwitch G8052 Description and Specifications BPP-00038-00, September 2010
Protocols
SNMP v1, v2, v3
Remote Monitoring (RMON)
Network Time Protocol (NTP) support
DHCP
Software upgrades
Dual software images
Upgrade via serial, browser, or TFTP
Software Features
Security
Secure interface login & password
RADIUS and TACACS+
SSH v1, v2
HTTPS Secure Browser-based interface
Wire-speed filtering with Access Control Lists (ACLs)
Layer 2
1024 VLANs (802.1Q), including Private VLANs
Multi-link trunking, compatible with Cisco EtherChannel
LACP (IEEE 802.3ad)
Spanning Tree (802.1D), Multiple Spanning Tree (802.1s), Rapid Spanning Tree (802.1w),
with Fast Uplink Convergence
32K forwarding database entries
Layer 3
Dynamic routing
- RIP v1, v2
- OSPF
- BGP
128 configurable interfaces (static or DHCP)
DHCP Relay
IP forwarding
IGMP Snooping v1, v2, v3
8K ARP entries
IPv6 host management
Quality of Service
802.1p priority queues
Differentiated Services Code Point (DSCP) support
Availability
Layer 2 Failover
Hot Links
VRRP

RackSwitch G8052 Installation
BPP-00038-00, September 2010 Chapter 1: RackSwitch G8052 Description and Specifications 9
Switch Components
This section describes the RackSwitch G8052 hardware components.
Hardware Options
The following list provides an overview of G8052 hardware:
Switch unit
Mounting hardware
Standard 2-post rack mounting brackets and screws
Standard 4-post rack mounting brackets and screws
iDataPlex rack mounting brackets and screws
System-X 4-post rack mounting brackets and screws
Hot-swap power supply (2)
Hot-swap fans (up to 4)
Switch Unit
The RackSwitch G8052 switch unit is a 1U rack-mountable Gigabit Ethernet switch. You can
mount the G8052 in either the horizontal or vertical direction.
The RackSwitch G8052 allows for flexible mounting of the switch, as follows:
RackSwitch G8052F provides front-to-rear airflow.
RackSwitch G8052R provides rear-to-front airflow.
Ports
The switch unit contains
Forty-eight 10/100/1000BaseT ports (RJ-45)
Four 10GbE SFP+ ports
USB port for mass storage
RS-232 serial console port

RackSwitch G8052 Installation
10 Chapter 1: RackSwitch G8052 Description and Specifications BPP-00038-00, September 2010
Figure 1 RackSwitch G8052 Front Panel
Figure 2 RackSwitch G8052 Rear Panel
RJ-45 Ports
RS-232 Port
Reset
Button
System Status LEDs
SFP/SFP+ Ports
USB Port
OK
~AC
!
OK
~AC
!
Fan Modules
IEC320
Power Connector
Power
Supply Module
Power
Supply Module
IEC320
Power Connector
Indice
Altri manuali Blade Interruttore