Blickfeld Qb2 Manuale di istruzioni

Qb2
QUICK START MANUAL AND
SAFETY INFORMATION

Publ. #49039-EN-Rev1.0-20230517
This manual contains information necessary to safely mount,
install and start up the Qb2 LiDAR sensor manufactured by
Blickfeld GmbH. It provides important information regarding
the use of said product and is intended for qualified person-
nel that is familiar with the local work safety regulations and
general safety regulations for laser products.
Personnel intended to operate the Qb2 must be familiar
with the safety information and instructions provided in this
manual before use.
For more information and additional user guides, visit
www.docs.blickfeld.com/qb2.
Blickfeld GmbH
Barthstr. 12
80339 Munich, Germany
www.blickfeld.com
DESCRIBED PRODUCTS
Name: Qb2
Model No’s.: QB2-AWP-ST1xxx, QB2-AWP-ETRxxx
©2023
This user manual or excerpts therefrom may not be reproduced
or forwarded to third parties without the explicit permission
of the Blickfeld GmbH.
Contents are subject to change and errors excepted.

3
Contents
Safety information ............................................
1.1 Intended use .............................................................................. 4
1.2 Safety instructions .................................................................. 4
1.3 Use restrictions ......................................................................... 7
Product description ..........................................
2.1 Product overview ..................................................................... 8
2.2 Technical data .......................................................................... 9
Installation .........................................................
3.1 Requirements ............................................................................ 11
3.2 Mounting ...................................................................................... 11
3.3 Electrical installation ............................................................. 12
Accessing the Qb Web Interface .................
Service and Maintenance ................................
5.1 Service and repair information ........................................ 15
5.2 Cleaning ........................................................................................ 15
Storage and disposal .......................................
6.1 Storage ........................................................................................... 16
6.2 Disposal ......................................................................................... 16
Customer service/support .............................
Compliance Information ..................................
8.1 EU Declaration of Conformity ......................................... 18
8.2 UK Declaration of Conformity .......................................... 18
8.3 FCC Compliance Statement ............................................. 18

Safety information
4
1 Safety information
1.1 Intended use
The Qb2 is designed for continuous measurement of point
cloud data using 3D laser ranging (LiDAR). This enables con-
tact-free measurement of distances and contours of the
objects in the field-of-view of the Qb2. Configurable zones of
interest in combination with advanced on-device data pro-
cessing capabilities allow deriving actionable insights such
as stockpile volumes, intrusion detection, and many more.
Blickfeld assumes no liability for damage and danger caused
by unintended or incorrect use. Any use of the Qb2 outside
of the defined technical specifications and requirements
described in this manual is considered unintended use.
1.2 Safety instructions
The user of the Qb2 must comply with all local regulations
for the operation of laser devices. Despite its high robustness
compared to other LiDAR technologies, the Qb2 is a precise
optical measuring device and must be handled with care.
The Qb2 is a scanning LiDAR sensor with a built-in laser that
emits pulses of laser beams with a wavelength of 905 nm,
which is invisible to the human eye.
Caution – use of controls or adjustments or performance of
procedures other than those specified herein may result in
hazardous radiation exposure.

Safety information
5
•Never open the protective housing. The unit is not user-
serviceable.
•Ports that are unused during operation or storage must
be fitted with the supplied protective caps to maintain the
ingress protection rating of the protective housing.
•Observe the local regulations for the use of radio equipment
in the 2.4 and 5 GHz frequency bands, in particular when
using the unit in outdoor areas.
•The Qb2 is not permitted to be used in potentially explosive
or corrosive environments.
•The Qb2 is not a safety component within the scope of the
Machinery Directive (2006/42 EC) or comparable regulations.
•Prevent strong shaking or vibrations, e.g. due to dropping
of the Qb2 as this can permanently damage the optical
components.
•The Qb2 may only be operated within the environmental
conditions stated in the technical data below.
•The Qb2 is not a handheld or body-worn device. The safety
distance for avoiding harmful long-term exposure to
electromagnetic fields is 5 cm.
•Do not co-locate the unit with other radio transmitters or
antennas.
•The Qb2’s radio transmitter has been certified for use with
the antenna provided together with the unit. Use of any other
antenna invalidates the certification and is strictly prohibited.
•Never try to operate the Qb2 if an obvious damage or
abnormal behavior of the device is discernible.
•Power down the device and store it safely in a dry location
together with this user information when not in use.

Safety information
6
The Qb2 is a Class 1 laser product according to
EN/IEC 60825-1 Ed. 3 2014.
CAUTION Invisible laser radiation
The Qb2 incorporates a Class 3B embedded
laser. Any modifications to the Qb2 or incorrect
use can increase the level of risk of exposure to
hazardous quantities of invisible laser radiation,
which may pose a danger to the eyes and skin.
•Never open the protective housing of the Qb2.
The unit is sealed and is not user-serviceable.
•Do not intentionally stare into the optical
aperture of the Qb2 from close distance while
the Qb2 is switched on.
•No service or repair work may be performed
except by personnel authorized by the
manufacturer.
•Adhere to the applicable national regulations
on optical radiation protection.
WARNING Electrical voltage!
Inside the protective housing, hazardous voltages
are present in the energized state. Electrical voltage
can lead to serious injury or death.
•Never open the protective housing of the Qb2.
•The power supply equipment must meet all
requirements specified in this manual and be
certified to meet the relevant national safety
standards.

Safety information
7
•Custom electrical installations must be carried
out by qualified electricians.
•Never try to operate the Qb2 if an obvious
damage of the device or its protective
enclosure is discernible.
CAUTION Hot surface!
During and shortly after operation the mounting
surface of the Qb2 can be hot enough to poten-
tially cause skin burn.
•Avoid contact of the skin with enclosure
during operation and let the sensor cool down
after operation.
1.3 Use restrictions
This device is restricted to indoor use
only when operating in the 5150 –
5350 MHz frequency range within
all EU member states, the UK, and
Switzerland. It will not initiate radio
transmission in this frequency band.
Follow the online user guide under
www.docs.blickfeld.com/qb2 to
learn more about using the wireless
features of the Qb2.

Product description
8
2 Product description
2.1 Product overview
1
4 2 2
3 33
QB2-AWP-ST1xxx QB2-AWP-ETRxxx
Fig. 1 Figure 1 Qb2 overview. Qb2 front (left),
back (center and right).
1 Optical aperture (front)
2 M12 Ethernet port
3 Antenna port
4 Venting membrane.

Product description
9
2.2 Technical data
Model No. QB-AWP-STxxx QB-AWP-ETRxxx
Laser class Class 1 (IEC 60825-1:2014, Ed. 3)
Power consumption Typ. 10 W (max. 13 W)
Operating voltage Power over Ethernet
Type 1 PD (IEEE 802.3at)
Data and power
connector
8-pin M12 Industrial Ethernet connector,
X-coded (DIN EN 61076-2-109)
Maximum altitude 2000 m / 6560 ft above sea level
Operating ambient
temperature
-30 °C ... +40 °C /
-22 °F ... +104 °F
-30 °C ... +60 °C /
-22 °F ... +140 °F
Storage ambient
temperature
Long-term:
30 °C ... +60 °C / -22 °F ... +104 °F
Transport:
-30 °C ... +80 °C / -22 °F ... +176 °F
Humidity Max. 90% at 30 °C, non-condensing
Housing materials Optical window: Polycarbonate, coated
Metal enclosure: Aluminum, coated
Ingress Protection IP67 (IEC 60529)

Product description
10
Model No. QB-AWP-STxxx QB-AWP-ETRxxx
Weight Ca. 400 g / 0.882 lb Ca. 535 g / 1.18 lb
Dimensions Ca. 75 mm x 111
mm x 53 mm /
2.95 in x 4.37 in x
2.07 in
Ca. 75 mm x 111
mm x 83 mm /
2.95 in x 4.37 in x
3.27 in
Frequency bands 2402 – 2472 MHz
5150 – 5330 MHz (Indoor use only)
5490 – 5730 MHz
Max. transmit power 2.4 GHz: 20 dBm
5 GHz: 20 dBm
Altri manuali per Qb2
1
Indice
Altri manuali Blickfeld Radar