6 Ussc
ASSEMBLY INSTRUCTIONS
Combustion Air Intake
This appliance requires a source of combustion air. If you home is of tight construction or has nega-
tive pressure problems, you will need an outside source of air.
You have two options. You may cut a rectangular hole in the floor of your home and the floor protector, or
purchase a standard 4” Dryer Vent kit from your local hardware supply store and install it on the rear of the
pedestal.
If your choice is to cut a rectangular hole in the floor and flooring protector, refer to the below illustrations for
assistance. You must place a rodent screen between the floor protector and the floor to prevent passage of
any unwanted vermin into your home.
If using a Dryer venting kit, the outlet cover must be of a design that DOES NOT close by means of
a flap or trap door. You must purchase a style that allows a continuous in-flow of air and that has a rodent
screen. You will also need a Combustion AirAdapter to attach to the pedestal of the appliance. This adapter
can be purchased from your dealer.
If your home is not of tight construction, you can just simply remove the 4” round knockout in the rear of the
pedestal.
“Combustion Air thru Unit Base” installation:
First,decide thelocation of theappliance.Then, cuta 2”x 6”rectangular openinginthe floorprotector
within the appliance base’s perimeter. Using the flooring protector as a template, position it in place
and mark onto the floor of your home where to make your next cut. Make the cut in your home’s floor
slightly larger than the 2” x 6” to accommodate any misalignment.Attach a piece of screen over the
hole to prevent any unwanted vermin entering your home. Complete your appliance install.
“Dryer Venting Kit” installation:
Beginby installingthe 4” adapterto therear ofthe applianceusingthe screwsprovided. Ifnot already,
remove the round knock-out from the pedestal. Follow the manufacturer’s installation instructions for
attaching the dryer vent kit to the home. Then attach it to the adapter on the appliance.
“Combustion Air thru Unit Base” Installation “Dryer Venting Kit” Installation
FLOOR PROTECTOR Home’s Floor
Rodent Screen
Non-Combustible Floor
Make a 2” x 6” (51mm x 152mm)
cutout through both the oor
protector and home’s ooring
within the perimeter of the
appliance’s base.