gummy cereals (e.g. oats or rye) you can include rice hulls to help counter-act the ‘gummy’ eect
and keep the bed uid. Also, using a good grain mill to crush your grain evenly is important. We
recommend you consider the Crankandstein 328G (fully geared 3-roller mill) and have found the
factory setting (0.045”) to provide a good size for good uidity and conversion.
Second, if doing a single-step mash, if the strike temperature is properly calculated it is not criti-
cal to pump the wort during mash and it can be simpler not to. With the Mash Colander inserted
in the fermenter it is eectively surrounded by a water bath that will help maintain the tempera-
ture. The element keeps the water bath at the target temp for mashing, and warms the colander
which warms the mash. When mashing is almost complete, the pump can be operated to move
the water under the colander to the top of the grain bed for vorlauf. While care still needs to be
taken, during vorlauf it is less likely that your mash will stick or that you will run out of water in
the cone portion of the fermenter where the element is, especially if the next step is followed.
Third, if circulating during the mash, or during vorlauf, if the water level starts to rise in the Col-
ander, it means wort is being pumped out of the bottom faster than it is being replenished and
the pump outow should be slowed (in time, if the ow is not slowed, the element will be ex-
posed and could be damaged). To prevent the pump from moving wort to quickly, a valve must
be installed on the downstream side of the pump (either on the pump outlet or on the Mash Col-
ander port; on larger systems the latter might be an easier location for controlling the ow rate
and liquid level in the Mash Colander) and partially close it to slow the amount of wort moved
out of the bottom. (Don’t close or restrict a valve BEFORE the pump in any way as this ‘starves’
the pump and can damage it.) If grain that has fallen through the Colander plugs the pump line,
open the valve wide momentarily to move the grain into the Mash Colander or attach the pump
intake line to the cone side-racking port, rather than the bottom port of the fermenter (although
if possible it is better for uniform ow through the Colander to keep the pump line connected to
the bottom port).
Fourth, with the Power Controller, power output can be set to around 20-30% during mash
which is typically more than enough to maintain mash temperature, while minimizing the chance
that the element will be ruined if temporarily exposed.
Note 1: Throttling the pump (by partially closing a downstream valve) is also the best way to pre-
vent pump cavitation. Cavitation occurs when the pump is pushing liquid out faster than it can
draw it in. This creates a vacuum which causes a ‘cavity’ to form, which prevents ecient operat-
ing of the pump (a screeching sound from the pump is most often caused by cavitation). When
the ow is throttled back on the exit side by partially closing a valve, it prevents liquid from being
pushed out faster than it can be drawn in, preventing the cavity from forming.
Note 2: When brewing low volume batches, it is also important to be careful that the element is
not exposed during the boil. To ensure that the water level will not drop to the point where the
6
BIAC User Manual Safety
Caution: A ‘squealing’ sound in the pump often indicates a cavity and the pump
should be turned o immediately. See more information in ‘Installation’ section.