CAME QBEMFSB2 Manuale utente

Gateway per Automazioni
QBEMFSB2
MANUALE DI INSTALLAZIONE E CONFIGURAZIONE
IT
Italiano
EN
English
FR
Français
PL
Рolski
FA01328M4A

85
85
78,5
A
B
A
Pag. 2- Manuale FA01328M4A - 05/2019 - © CAME S.p.A.. - Istruzioni originali
I contenuti del manuale sono da ritenersi suscettibili di modifica in qualsiasi momento senza obbligo di preavviso.

FG
E
C
D
B
Pag. 3- Manuale FA01328M4A - 05/2019 - © CAME S.p.A.. - Istruzioni originali
I contenuti del manuale sono da ritenersi suscettibili di modifica in qualsiasi momento senza obbligo di preavviso.

Page 19 - Manual FA01328M4A - 05/2019 - © CAME S.p.A.. - Translation of the original instructions
The contents of this manual may change, at any time, and without notice.
ENGLISH
General Precautions
• Carefully read the instructions before starting installation and
performing any procedures as explained by the manufacturer. •
The installation, programming, commissioning and maintenance
of the product must only be carried out by qualified technicians,
properly trained in compliance with the regulations in force,
including health and safety measures and the disposal of
packaging. • Before carrying out any cleaning or maintenance
operation, disconnect the device from the power supply. • The
equipment must be destined solely for the use for which it was
expressly designed. • The manufacturer cannot be held liable for
any damage resulting from wrongful, improper and unreasonable
use.
Cautionary issues on remotely controlling the
device
Some features of the system may be managed by smartphones
and tablet PCs, by using the corresponding apps. • For the
system to be remotely controlled, the device must be connected
to a home network with internet access. • Remotely controlling
the device via app means that the data trac consumption takes
place over the home network of the smartphone or table PC; the
cost deriving from this consumption is charged to the user.
Description
QBEMFSB2 communicates with compatible wireless devices and
connects to the internet through wired LAN or Wi-Fi connection.
Devices connected to QBEMFSB2, once registered with CAME
Cloud, can be remotely controlled through a Smartphone or
Tablet by a specific application.
Description of parts
ALAN cable for connecting the device to a router
BUSB power supply
CButton
DWarning LED
ELAN cable connector
FPower-supply connector
GBlue LED that indicates the device activity status
LED function
D They turn up every time an activity is detected on the
networks:
Green - Wi-Fi
Yellow - LAN

Page 20 - Manual FA01328M4A - 05/2019 - © CAME S.p.A.. - Translation of the original instructions
The contents of this manual may change, at any time, and without notice.
Red - radio frequency. If the LED flashes regularly (once per
second) it means that there are problems with radio frequency
communication.
GThe blue light on the button indicates that the device is being
configured. The blue steady light indicates that the device is
operating; this message can be disabled.
Function of the Cbutton
Pressed for more than 5 seconds, it enables/disables the blue
light at the base of the device which indicates that the device
is operating.
Pressed for more than 30 seconds and released after the red LED
flashes, it returns to the following settings:
LAN: IP (static) = 192.168.1.80
Wi-Fi: Access Point (SSID: QBE_0x0373xxxx) = 192.168.9.1
Technical data
Models USB power supply
Power supply (Vac) 100-240
Frequency (Hz) 50-60Hz
USB output (V) 5 series
Maximum output current (mA) 2400 series
Models QBEMFSB2
Power supply DC (V) 5 series
Consumption (mA) 200 series
Radio signal power at 869.5MHz (dBm) 14 series
Range of the 869.5MHz radio signal in a free
area (m) 200 series
Standard wireless (IEEE)
802.11b,
802.11g,
802.11n
WIFI frequency field (MHz) 2,412 - 2,472
Maximum WIFI transmission strength (dBm) 18 series
Maximum length of the Ethernet Cat. 5 cable
(m) 100 series
Operating temperature (°C) 5 to 40
Stocking temperature °C -25+70°C
Protection rating (IP) IP30

Page 21 - Manual FA01328M4A - 05/2019 - © CAME S.p.A.. - Translation of the original instructions
The contents of this manual may change, at any time, and without notice.
Limits to use
Maximum number of devices that can be controlled
Type Quantity
RSLV001 Modules 5 series
Operators 25 series
Installation
Place the device away from metal objects that can shield the
signal or devices that generate magnetic fields.
Interpose as few as possible walls between the device and the
router.
The device configuration is performed through WEB interface.
The device can be used without having to change the
default configuration. The settings described below are only
necessary if the network settings have to be changed.
Access to configuration pages through Ethernet
cable connection
Connect the device to your PC (router, switch) using the Ethernet
cable supplied.
Connect the power supply to the device and to the mains.
The device automatically takes the configuration from the network
to which it is connected (DHCP).
Access to configuration pages through Wi-Fi
connection
The device generates its own Wi-Fi network.
Connect the power supply to the device and to the mains.
Search on your PC (tablet, smartphone) the Wi-Fi network
generated by the device (SSID:QBE_0x0373xxxx).
Type the address of the device (192.168.9.1) in the address bar
of the browser (Chrome, Firefox, Safari).

Page 22 - Manual FA01328M4A - 05/2019 - © CAME S.p.A.. - Translation of the original instructions
The contents of this manual may change, at any time, and without notice.
Configuration
Select the “INSTALLER” access option and enter the password,
which is set to “112233” by default, to access the settings
windows.
Access with "User" credentials (default password 123456)
allows access to the pages described below in a simplified
manner.
Accessing with "Admin" credential is only for skilled
technical sta, and is for extraordinary maintenance.
Authorization requested
Please enter your username and password.
Language
Log-in Mode
Password

Page 23 - Manual FA01328M4A - 05/2019 - © CAME S.p.A.. - Translation of the original instructions
The contents of this manual may change, at any time, and without notice.
[Status]
[Summary]
This screen show technical information that is useful to identify
the device’s characteristics and the network status.
[System log]
The section lets you generate file that contain data useful for
technical servicing aimed at finding any system malfunctions.
[Kernel Log]
The section lets you generate file that contain data useful for
technical servicing aimed at finding any kernel malfunctions.
Status System Network General Options Exit
Summary
System
Model
Serial number
Hardware version
Serial Interface 868
Serial Interface 869
Keycode
Software version
Firmware version
Activity time
Ethernet
Network Status

Page 24 - Manual FA01328M4A - 05/2019 - © CAME S.p.A.. - Translation of the original instructions
The contents of this manual may change, at any time, and without notice.
[System]
[Properties]
[Date setting]
ASelect from the list, the Continent - State/City where the
system is installed.
BSynchronize date and time with the browser.
CWith NTP client active, in this space provide the NTP server
address/addresses through which the device will synchronize the
date and time.
[Password]
Enter the new password The new password replaces the one
used for access.
Status System Network General Options Exit
Status System Network General Options Exit
Properties
Date setting
Time zone
Local time
Synchronize
with the browser
NTP settings
Activate the NTP client
Password
Confirm button
Europe/Rome
Password
Change the access password to the device
A
B
C

Page 25 - Manual FA01328M4A - 05/2019 - © CAME S.p.A.. - Translation of the original instructions
The contents of this manual may change, at any time, and without notice.
[Maintenance]
[Software Update]
ASelect the file containing the software update on your
computer, and start the update.
[Configuration]
BPress the button to start the procedure for restoring the
default conditions.
NOTE: This reset does not change the network settings configured
on the device.
Status System Network General Options Exit
Status System Network General Options Exit
Maintenance
Software Update Configuration
Maintenance
Software Update Configuration
Software Update
Select a compatible update file to update the current firmware.
Restore factory settings
ATTENTION: continuing, it is possible to bring the device back to the factory
configuration (excluding network settings)
Image: Choose file
Update
Start Restore
No file selected A
B
Altri manuali per QBEMFSB2
2
Indice
Altri manuali CAME Hardware di rete
Manuali Hardware di rete popolari di altre marche

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manuale utente

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manuale utente

Yudor
Yudor YDS-16 Manuale utente

D-Link
D-Link ShareCenter DNS-320L Manuale utente

Samsung
Samsung ES1642dc Istruzioni per l’uso

Honeywell Home
Honeywell Home LTEM-PV Istruzioni per il montaggio