Cansec SmartLock UltraLite Plus Manuale utente

SmartLock®UltraLite Plus
INSTALLATION MANUAL
October 2015

SmartLock®UltraLite Plus Page 2 of 16
Installation Manual Oct 2013 • Rev. 1.6
Table of Contents
INTRODUCTION ........................................................................................................................................... 3
SPECIFICATIONS......................................................................................................................................... 4
BOARD LAYOUT.......................................................................................................................................... 5
WIRING ......................................................................................................................................................... 6
LOCK RELAY WIRING............................................................................................................................... 10
TROUBLESHOOTING ................................................................................................................................ 14
SMARTLOCK ULTRALITE PLUS COMPLIANCE STATEMENT............................................................... 15
Copyright 2012 - 2015 Cansec Systems, Ltd.
All rights reserved.
Connector Installation Note................................................................................6
Wiegand Reader................................................................................................7
iButton®Reader ................................................................................................. 8
Exit Button and Door Contact.............................................................................9
DC Electric Strikes (up to 250mA)....................................................................10
DC Electric Strikes (more than 250mA) ...........................................................11
AC Electric Strikes ...........................................................................................12
AC Maglocks....................................................................................................13

SmartLock®UltraLite Plus Page 3 of 16
Installation Manual Oct 2013 • Rev. 1.6
Introduction
SmartLock UltraLite Plus is an extremely simple, stand-alone access control system that
supports up to 2,000 users with a 1,000 record, time-stamped audit trail capacity. All
programming is done at the PC, using software which is simple, intuitive and supports
up to 255 UltraLite Plus controllers. When used with the CanProx One proximity
reader, the UltraLite Plus system becomes one of the most cost-effective stand-alone,
expandable systems on the market.
The SmartLock UltraLite Plus controller features a form "C" relay output for lock
control as well as inputs for a request-to-exit button and a door contact. If a door
contact input is connected, the controller will automatically relock the door once it re-
closes. In addition, an audible alert can be generated on the reader if the door is held
open longer than a specified time.
IMPORTANT: If no door contact is used, the door contact input must be shorted to
ground. Failure to do this will result in erratic operation.
NOTE: Tech Support will only be provided where product installation guidelines
have been followed.
IMPORTANT: In some jurisdictions the use of a UL-approved power supply
and connection to the fire alarm system for emergency release may be
required. Installers should contact the fire marshal office or local
authority having jurisdiction to verify the specific requirements. A building
permit may be required in some jurisdictions for the installation of maglocks.

SmartLock®UltraLite Plus Page 4 of 16
Installation Manual Oct 2013 • Rev. 1.6
Specifications
Power Requirements
UltraLite Plus controller ........................................................................12 VDC, 40 mA
NOTE: When determining power supply current requirements, add lock and reader current draw.
Onboard Output
Lock control relay.........................................................form “C”, rated @ 30 VDC, 2 A
Onboard Inputs
Exit button ............................................................................................... normally open
Door contact........................................................................................... normally closed
Reader Cable
Wiegand readers..................................................6 conductors (twisted pair not required)
..................................................................................#22 AWG, overall shielded cable
.......................................................................................................... 152 m [500'] max.
iButton®readers................................................................................................. 6 conductors
......................................................................#22 AWG, shielded or unshielded cable
...............................................................................................................15 m [50'] max.
Dimensions
UltraLite Plus controller .............................114.3 mm (h) x44.5 mm (w) x25.4 mm (d)
...........................................................................................[4.5'' (h) x1.75'' (w) x1'' (d)]
Operating Temperature.............................................. -35oC to 65oC [-31oF to 150oF]
Housing................................................................................................... polycarbonate
Specifications subject to change without notice.
IMPORTANT: In some jurisdictions the use of a UL-approved power supply
and connection to the fire alarm system for emergency release may be
required. Installers should contact the fire marshal office or local
authority having jurisdiction to verify the specific requirements. A building
permit may be required in some jurisdictions for the installation of maglocks.

SmartLock®UltraLite Plus Page 5 of 16
Installation Manual Oct 2013 • Rev. 1.6
Board Layout
NOTE:
1. Only connect a power source to the indicated power pins or product damage will result.
2. The door contact input must be bypassed if not used. To bypass, connect a jumper wire
between the door contact input and Ground.
3. If the cable feed hole on the controller back-box is too small, drill a larger hole to
accommodate the cable.
4. The controller comes in polycarbonate housing, and should be installed in an accessible
location on the secure side of the door.
5. The housing is not waterproof.

SmartLock®UltraLite Plus Page 6 of 16
Installation Manual Oct 2013 • Rev. 1.6
Wiring
CONNECTOR INSTALLATION NOTE
IMPORTANT:
Wires face into the center of the PCB for installation into housing.
CONNECT WIRES ONTO THE
PLUGGABLE CONNECTORS
IN THIS ORIENTATION
ATTACH CONNECTORS
AS SHOWN

SmartLock®UltraLite Plus Page 7 of 16
Installation Manual Oct 2013 • Rev. 1.6
WIEGAND READER
IMPORTANT: Before applying power to the controller, verify that the reader is
connected correctly as per the manufacturer’s specifications.
6 CONDUCTOR, 20 AWG
NON-TWISTED PAIR
SHIELDED CABLE
MAX. DISTANCE IS 500 FT.

SmartLock®UltraLite Plus Page 8 of 16
Installation Manual Oct 2013 • Rev. 1.6
IBUTTON READER
6 CONDUCTOR, 22 AWG
TWISTED OR NON-TWISTED PAIR
SHIELDED CABLE
MAX. DISTANCE IS 50 FT.

SmartLock®UltraLite Plus Page 9 of 16
Installation Manual Oct 2013 • Rev. 1.6
EXIT BUTTON AND DOOR CONTACT
NOTE:
1. Do not apply power or attempt to switch any current through these inputs as this
will result in damage to the controller.
2. The door contact input is used for forced entry and door-held-open
annunciation. The lock relay is deactivated when the door closes before the
unlock time ends.
3. If door contact is not used, you must connect a jumper wire between the door
contact input and Ground. Connecting a door contact will enable door-held-
open annunciation via the reader’s beeper and will also deactivate the lock relay
when the door closes before the unlock time ends.
4. Requires momentary closure to activate the lock relay.

SmartLock®UltraLite Plus Page 10 of 16
Installation Manual Oct 2013 • Rev. 1.6
Lock Relay Wiring
DC ELECTRIC STRIKES (UP TO 250MA)
NOTE: Use a 1N400x series diode at the lock device as shown to prevent “back EMF”
from damaging the controller.