Cansec SmartFob SFR-200 Manuale utente

Smartfob Receiver
INSTALLATION MANUAL
(SFR-200 MN: SFR2RXB)
FCC- and IC-compliant
receiver
July 2008 Cutting edge simplicity


Table of Contents
Introduction...........................................................................................................................4
Specifications .......................................................................................................................5
Configuration & Wiring........................................................................................................6
•Antenna, JP3 and Relays 1&2.............................................................................................................6
•JP1 and LED1......................................................................................................................................7
•How to Reduce Range.........................................................................................................................8
•DIP switch S1, Wiegand Output and Power Input................................................................................9
•Reset Button, AUX outputs & JP4, JP5, JP6.....................................................................................12
Measuring RSSI Voltage....................................................................................................13
•RF NOISE..........................................................................................................................................13
•Dipole vs Vertical Antennae...............................................................................................................14
Mounting Recommendations............................................................................................14
Wiring Sample.....................................................................................................................15
•Split Mode..........................................................................................................................................15
•Common Mode..................................................................................................................................16
FCC and IC Compliance Statement ..................................................................................17
•Information to Users (FCC 15.21 & 15.105).......................................................................................17
•Warning to Users (FCC 15.21 & 15.105)...........................................................................................17
•Industry Canada Compliance Statement: ..........................................................................................17
©2008 Copyright Cansec Systems Ltd.
All rights reserved
Smartfob Receiver MN: SFR2RXB Page 3 of 17
Installation Manual July 2008 • Rev. 1.0

Introduction
The SmartFob SFR-200 receiver (replaces the SFR-100) detects radio
frequency (RF) signals from the Cansec SmartFob (SFT-200) transmitter.
The receiver comes with two sets of onboard relay contacts, which may be
activated via a DIP switch. A Cansec SmartFob transmitter will cause the
relay contacts to toggle on and off for approximately one second. A typical
use for these relay contacts is to turn on a indicator light to let users know
when data from SmartFob transmitters is received and decoded correctly.
After the receiver decodes the RF signal from the transmitter, it will output
Wiegand data to an access controller. The Cansec SFT-200 transmitter has
two buttons:
•Button I
•Button II
The SFR-200 receiver may be configured via a DIP switch to operate in:
•Common Mode - data from Button I and II is sent via AD0 and AD1
•Split Mode - data from Button I is sent via AD0 and AD1, and data
from Button II is sent via BD0 and BD1
A typical example of the split mode of operation is IN / OUT functionality
for two-door garage applications.
•increased signal reception range
•better noise filtering (at 315 MHz)
•standard 26-bit or Cansec 37-bit Wiegand output to an access controller
•interchangeable with existing SFR100 receivers
•audible indicators help with troubleshooting
•RSSI signal indicates RF interference to aid in proper receiver placement
•vertical antenna supplied
(
dipole antenna available
)
Features:
Smartfob Receiver MN: SFR2RXB Page 4 of 17
Installation Manual July 2008 • Rev. 1.0

Specifications
Power Requirements: ......................................................12 VDC, 100 mA
Wiegand Cable: ..............22 AWG, 6 conductors (AD0,AD1 & BD0,BD1)
.......................................................or 4 conductor (AD0 & AD1), stranded,
................................... overall shield; maximum 152 m (500 ft) to controller
Input Frequencies:
Model SFR2RXB............................................................................. 418 MHz
Output Formats: ..................................................26-bit standard Wiegand;
.................................................................................. 37-bit Cansec Wiegand
Transmission Reception Range:.............................................. 45 m (150 ft)
Temperature Range: ...................................-40°C to 70°C (-40°F to 158°F)
Dimensions: ................................... 152 mm (w) x 114 mm (h) x 46 mm (d)
.................................................................... [6 in (w) x 4.4 in (h) x 1.8 in (d)]
Weight: ...................................................................................310 g (10.8 oz)
Installation Environment: ................................................. indoor/outdoor
*Specifications subject to change without notice
Smartfob Receiver MN: SFR2RXB Page 5 of 17
Installation Manual July 2008 • Rev. 1.0

Configuration & Wiring
ANTENNA, JP3 AND RELAYS 1&2
A: ANTENNA CONNECTOR
“F” Type, 3/8” – 32
B: JP3
[ Default position: Jumper 1 & 3 OUT (pins not shorted); jumper 2 IN (pins
shorted) ]
JUMPER 1 OUT = On-board Beeper disabled
IN = On-board Beeper enabled (sounds when valid data is received)
JUMPER 2 OUT = Accepts SF200 Transmitters only (binary stream support)
IN = Accepts SFR100 or SFR200 transmitters (SF100 Mode)
JUMPER 3 N/A = Reserved for future use.
Smartfob Receiver MN: SFR2RXB Page 6 of 17
Installation Manual July 2008 • Rev. 1.0

JP1 AND LED1
C: RECEIVED SIGNAL STRENGTH INDICATION (RSSI) ADJUSTMENT
(Top 2 pins) = RSSI is OFF (default position maximum sensitivity and
range).
(Bottom 2 pins) = RSSI is ON. Carefully adjust for range. For noise
rejection set VR1 just below the point that causes LED1 to turn off.
NOTE: will be constantly flashing if unit is at maximum sensitivity or if
is set to Maximum Range.
It is best to operate the SFR-200 is with the RSSI jumper set to OFF (receiver
is set to its maximum receive range).
Smartfob Receiver MN: SFR2RXB Page 7 of 17
Installation Manual July 2008 • Rev. 1.0

Smartfob Receiver MN: SFR2RXB Page 8 of 17
Installation Manual July 2008 • Rev. 1.0
HOW TO REDUCE RANGE
To reduce the receive range, set the RSSI jumper to ON and adjust VR1 to
the required reduced range. The procedure is as follows:
1. Adjust VR1 position to the point where the LED1 just turns off.
NOTE: To aid in this adjustment the SFR-200 Receiver's audible beep
can be used. Each time a Cansec SmartFob transmitter is decoded
correctly the SFR-200 receiver will beep.
2. Adjust VR1 toward the (-) or reduced range.
3. Back away from the receiver and press the SmartFob transmitter. If no
audible beep is heard, the range has been exceeded.
4. Repeat this procedure until the required range is found.
NOTE: It is important to test more than one SmartFob transmitter to verify
this reduced range. It is also important to test the area of reception from all
different angles to the SFR-200 receiver.

Smartfob Receiver MN: SFR2RXB Page 9 of 17
Installation Manual July 2008 • Rev. 1.0
DIP SWITCH S1, WIEGAND OUTPUT AND POWER INPUT

D: DIP SWITCH
= Default position: Switch 1, 2, and 3 OFF; switch 4 ON
Switch 1
OFF = Common Mode.
Buttons I and II on the SmartFob transmitter will send data via
AD0 and AD1 and activate relay 1 if relay activation is on
ON = Split Mode.
Button I will send data via AD0 and AD1 and activate relay 1*
Button II will send data via BD0 and BD1 and activate relay 2*
Switch 2
OFF = A single valid data bundle is received and then Wiegand data is
sent to the access controller. See the DIP Switch 2
note
below.
ON = Receiver will read and validate and compare two successive data
bundles. If they are the same, then Wiegand data is sent to the
access controller. See the DIP Switch 2
note
below.
Switch 3 OFF = 37-bit Cansec propriety Wiegand.
ON = 26-bit standard Wiegand.
Switch 4 OFF = Relay activation off.
ON = Relay activation on.
DIP Switch 2: In extremely noisy areas, some random Wiegand data may
pass the decoding tests and produce an invalid number to the access control
panel. Enabling DIP switch 2 will eliminate the problem.