CAS LP-II Istruzioni di installazione e manutenzione

2001, CAS®(USA) CORPORATION EAST RUTHERFORD,NEW JERSEY 07073
REV: 3.0 Nov. 2006
LP-II
Electronic Price Computing
Label/ReceiptPrintingScale


Copyright©2006, by CAS Corporation. All rights reserved. No part of this publication may be
reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any
language or computer language, in any form or by any means, electronic, mechanical,
magnetic, optical, chemical, manual or otherwise, without the prior expressed written permission
of this company.
Attention:
This company makes no representations or warranties, either expressed or implied, with respect
to the contents hereof and specifically disclaims any warranties of merchantability or fitness for
any particular purpose. Any software describes in this manual is sold or licensed “as is”. Should
the programs prove defective following their purchase, the buyer (and not this company, its
distributors, or its dealers) assumes the entire cost of all necessary servicing, repair, and any
incidental or consequential damages resulting from any defect in the software. Further, this
company reserves the right to revise this publication and to make changes from time to time in
the contents hereof without obligation to notify any person of such revision or changes.
Disclaimer:
Brand and product names are trademarks and/or registered trademarks of their respective companies.

TABLE OF CONTENTS
PAGE
ii
1 Network Installation
1.1 Installing the Network Card............................................................................................1
1.2 Network Considerations..................................................................................................1
1.3 Interfacing.........................................................................................................................2
1.3.1 PC Master Hard-Wired or Wireless Ethernet Connection..........................................2
1.3.2 Scale Master Ethernet Connection with PC...............................................................4
1.3.3 Scale Master Ethernet Connection without PC..........................................................5
1.4 Wire Configuration............................................................................................................6
1.4.1 Ethernet Wire-Straight Cable and Crossover Cable..................................................6
1.5 Installing the Slave Scales (#2-32)....................................................................................7
1.6 Installing the Master Scale (#1)........................................................................................7
2 Network Management-Program Mode
2.1 Network Mode....................................................................................................................8
2.2 Network Copy.....................................................................................................................9
2.3 PLU Delete..........................................................................................................................11
2.4 Lock Network.....................................................................................................................12
2.5 Unlock Network..................................................................................................................13
2.6 Check Scale.......................................................................................................................13
3 Clerks
3.1 Networked Floating Clerk Option....................................................................................14
3.2 Networked Standard Clerk Option..................................................................................15
3.3 Non-Networked Floating Clerk Option............................................................................15
3.4 VOID Key in Floating Clerk Mode.....................................................................................15
4 Pinging
4.1 To Ping an IP Address.........................................................................................................17
APPENDIX
Appendix A-Network Connection Example-PC Master Type.............................................18
Appendix B-Network Connection Example-Scale Master Type.........................................19

1 Network Installation
1
1Network Installation
1.1 Installing the Network Memory Card
NOTE: New LP-IIs come with the Network Memory Card already installed. These instructions
can be used when replacing the card
1. Make sure that the Main Power switch is OFF & that the scale is unplugged.
2. Remove the keyboard:
A. Remove the 2 keyboard screws on top of the upper case.
B. Lay the keyboard face down.
3. Plug the Network Card into connectors J5 & J6 on the Main PCB. Make sure that all
of the pins are aligned properly and that the 2x9 connector is facing to the rear of
the scale.
4. Attach the 2 grounding screws to the Network Card PCB. Do not over tighten.
5. Reassemble in reverse order.
1.2 Network Considerations
The LP-2 uses a special high speed network called Ethernet. This allows you to connect up to
32 scales per installation site. The network is setup as a Master/Slave network that allows you to take
consolidated reports, transmit program data remotely, and manage up to 32 departments per site.
The network conduit configuration is star-topology. With a maximum speed of 4 Mbps and a max length
of 100 meters (325 feet), the LP-2 network can handle just about any application.
Please review the following when installing a network.
1. Check the overall network size and make sure that it falls within the limits.
2. Even though Ethernet cabling can be used, the use of Twisted pair Category-3,4,5
cable is preferred.
3. The network can run with a Master scale and no Mirror Master.
4. If you run into any trouble, please contact the CAS Service Department. We have
on-staff network specialists that can assist you if you run into any trouble or need to
exceed network specifications.

1 Network Installation
2
1.3 Interfacing
1.3.1 PC Master Hard-Wired or Wireless Ethernet Connection
PC(Master)
Slave Slave Slave Slave Slave
HUB
NOTE: Only 31 scales can be connected in this method.
PC must have Ethernet card.
Master scale (number 1) cannot be used.
Part I Setting Up the PC
In the Manager Program, go to Config and Select PC Master (TCP/IP)
1. Disable or disconnect any internet access
2. Under Control Panel in the Start menu, click on Network Connections
3. Right Click on the Local Area Network (LAN) icon and go to Properties
4. Go to Internet Protocol (TC/IP) and choose “Use the following IP address.”
5. Enter an address, which is a set of 4 numbers separated by a “.”-typically 192.168.xx.yy, where xx is the
third number of the network, and yy can be any number.
6. Enter the Sub Net Mask: 255.255.255.0
7. Click “OK” twice to exit
8. With a crossover Ethernet cable connected from the PC to either the router, scale, or bridge, “Ping”
the PC to verify settings (see “pinging” below)
Part II Setting Up the Scale
Under Network Options in the Calibration Menu
1. Network is Used: Yes
2. PC Master is Used: Yes
3. This Scale is Number (the scales can be given any number from 2-999).
NOTE: LP-II Manager only defaults to 5 scales. To add additional scales, Click on the Data Icon in
Manager and go to “Scales.”
4. Scale IP Address: 192.168.xx.yy-where xx
is the third number of the network, and yy is
the scale number
5. Sub Net Mask: 255.255.255.0

1 Network Installation
3
NUMERIC
( 2/ 2) < CAL: NETWORK OPTIONS >
PC UDP Port :[2001]
PC UDP Port (for Messenger) :{2000}
NUMERIC
( 1/ 2) < CAL: NETWORK OPTIONS >
Scale IP Address :[192.168.0.2]
Sub Net Mask :[255.255.255.0]
Gateway :[192.168.0.254]
PC IP Address :[192.168.0.1}
Scale UDP Port :[2002]
6. Gateway: This is used only for external
communication, and since we strongly
recommend these scales be set up on
a dedicated network, this setting is not
used
7. PC IP address (from Step 5 in Part I)
8 Scale UDP Port; 2002
9. PC UDP Port: 2001
10. (version 2.23 and higher) PC UDP Port
(for messenger):2000

1 Network Installation
4
1.3.2 Scale Master Ethernet Connection with PC (RS232C)
PC
Master Slave Slave Slave
HUB
NOTE: Only 32 scales can be connected in this method.
IN the Manager Program, go to Config and select Scale Master (RS-232C)
1. Scale number (for master) : 1
2. Scale number (for slave) : 2~32
3. Network is Used: Yes
4. PC Mater is Used : No
5. RS232C SPEC (all of these should default when RS-232C is selected in manager)
baud rate : 19200 bps
data length : 8 bit
parity : none
stop bit : 1 bit

1 Network Installation
5
1.3.3 Scale Master Ethernet Connection without PC
Master Slave Slave Slave Slave
HUB
NOTE: Only 32 scales can be connected in this method.
1. Scale number(for master) : 1
2. Scale number(for slave) : 2~32
3. PC master setting : No (refer to Error! Reference source not found. Error! Reference source not
found.)
4. Ethernet(10BaseT) SPEC
maximum segment length : 100 meter (328 feet)
media : Unshielded twisted-pair cable - Note
topology : star
Note : Scales(and other network devices) can be adversely affected by Electro-Magnetic
Interference(EMI). If the network cables must be run in proximity to strong sources
of EMI(Fluorescent light fixtures, AC motors, Air conditioning or Refrigeration compressors).
We STRONGLY recommend that shielded CAT 5 cable be used.

1 Network Installation
6
1.4 Wire configuration
1.4.1 Ethernet wire – straight cable and crossover cable
NOTE: Twisted pair Category-5 (UTP) cable with RJ45 Plug
`
Straight connection
HUB
8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1
RX-
RX+ TX-
TX+ TX-
TX+ RX-
RX+
Scale
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
RJ-45
Plug
RJ-45
Plug
`
HUB
8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1
TX-
TX+ RX-
RX+ TX-
TX+ RX-
RX+
HUB
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
RJ-45
Plug
RJ-45
Plug
Crossover connection
1.4.2 RS232C wire
9pin
D-SUB
(male)
9pin
D-SUB
(female)
1
2
3
4
5
6
8
9
7
1
2
3
4
5
6
8
9
7
To Scale To PC
NOTE: 1,4,6,7,8,9 pin do not use.
Altri manuali per LP-II
3
Indice
Altri manuali CAS Scala

CAS
CAS DL-60 Manuale utente

CAS
CAS BW-6 Manuale utente

CAS
CAS WEIGHING SOLUTION SWII PLUS Series Manuale utente

CAS
CAS LP-II Manuale utente

CAS
CAS CL3500 Series Manuale utente

CAS
CAS CL8000 Series Manuale utente

CAS
CAS AD series Manuale utente

CAS
CAS CL5000 Series Manuale utente

CAS
CAS PR-II Series Manuale utente

CAS
CAS NC-I Manuale utente

CAS
CAS CL series Manuale utente

CAS
CAS PB-II Manuale utente

CAS
CAS CASTON II Manuale utente

CAS
CAS PD-II Manuale utente

CAS
CAS MWP Manuale utente

CAS
CAS SW-1S Series Manuale utente

CAS
CAS PR-II Series Manuale utente

CAS
CAS SC Series Manuale utente

CAS
CAS CL5200 Series Manuale utente

CAS
CAS Atronics ACS Manuale utente





















