CAS XE 300 Manuale utente

2
XE 영문

3
Contents
TU1. IntroductionUT .............................................................................................................T5
2. Installation................................................................................................................6
3. Overview of Display Indicator and Keypad.........................................9
3.1 Display..................................................................................................................9
3.2 Keypad design....................................................................................................10
4. Operations..............................................................................................................12
4.1 Zero.....................................................................................................................12
4.2 Tare......................................................................................................................12
4.3 Weighing mode..................................................................................................12
4.4 Counting mode...................................................................................................13
4.5 Percentage weighing mode ...............................................................................14
4.6 Density measuring .............................................................................................15
4.7 Hold function......................................................................................................18
4.8 Check function...................................................................................................19
4.9 Units selection....................................................................................................20
5. User Menu Setting (Approval type ).......................................................21
5.1 Initial unit............................................................................................................21
5.2 Auto shut off time ..............................................................................................22
5.3 Serial port setting................................................................................................23
5.4 Data transmitting mode (For RS232C2)..........................................................24
5.5 Baud rate.............................................................................................................27
5.6 Data transmitting mode (For USB)...................................................................28
5.7 Unit weight re-computing .................................................................................30
5.8 Check alarm mode.............................................................................................31
5.9 Check alarm type ...............................................................................................32
5.10 IR key function.................................................................................................33
5.11 Date and time setting........................................................................................34
5.12 Printed date format setting...............................................................................36
5.13 Backlight...........................................................................................................37
6
. User Menu Setting (N , H type )..................................................................38
6.1. Span Carlibration...............................................................................................38
6.2 Initial unit.............................................................................................................39
6.3 Unit available ......................................................................................................40
6.4Auto shut off time................................................................................................41
6.5 Serial port setting ................................................................................................42

4
6.6 Data transmitting mode (For RS232C2)...........................................................43
6.7 Baud rate(For RS232-2 only) ............................................................................46
6.8 Data transmitting mode (For USB)...................................................................47
6.9 Unit weight re-computing..................................................................................49
6.10 Check alarm mode............................................................................................50
6.11 Check alarm type..............................................................................................51
6.12 IR key function .................................................................................................52
6.13 Date and time setting........................................................................................53
6.14 Printed date format setting ...............................................................................55
6.15 Backlight...........................................................................................................56
6.16 Stable class range..............................................................................................57
6.17 Zero display range............................................................................................58
6.18 Zero return range ..............................................................................................59
6.19 Zero tracking range...........................................................................................60
7. Power Supply........................................................................................................61
8. Data Transmitting..............................................................................................62
9. Error Messages....................................................................................................64
10. Data Sheet............................................................................................................65

5
1. Introduction
The balances are very simple to use and are applicable for general weighing. The
user can also use the parts counting and percent weighing functions for special
applications. Special functions are available for weighing in up to 10 different units
of weight.
For safe and dependable operation of this scale, please comply with the following
safety precautions:
• Verify that the input voltage printed on the AC Adapter and the plug type matches the
localAC power supply.
• Make sure that the power cord does not pose a potential obstacle or tripping hazard.
• Disconnect the scale from the power supply when cleaning the scale.
• Do not operate the scale in hazardous or unstable environments.
• Do not immerse the scale in water or other liquids.
• Do not drop loads on the platform.
• Use only approved accessories and peripherals, as available.
• Operate the scale only under ambient conditions specified in these instructions.
• Service should be performed by authorized personnel only.
• It must not be bumped against by other items or overloaded with excessively heavy
weights.
• Give a warm-up for 30mins before using the scale.

6
2. Installation
2.1 Unpacking
Unpack and verify that the following components have been included:
• Scale
• Steel pan
• Instruction manual
• ACAdapter
• RS232, USB Cable
• Five pieces of wind shield
2.1 Illustration of the installation for plastic shield

7
2.3 Selecting the location
Operate the balance on a firm and level surface.Avoid locations with rapid
temperature changes, excessive dust, moisture, air currents, vibrations,
electromagnetic fields, heat or direct sunlight.
2.4 Leveling the scale
Adjust the leveling feet until the bubble is centered in the circle of the level
indicator
Note:
Ensure that the balance is level each time its location is changed.
2.5 Loadcell Protection
First check a lock at the bottom of a scale
Before using the scale, release the lock
Unlock Lock

8
2.6 Replacement Mercury battery ( RTC battery - CR1220 )
After making a purchase, take out the Mercury battery(CR1220) sealed in the
plastic bag. Using a tool with a sharp point, pull the cover out in the direction
described in the image below. Place the battery inside and use it.

9
3. Overview of Display Indicators and Keypad
XE model series balance is a self-indicating weighing scale of Class II with single
weighing range, an external AC mains adapter, and an internal battery optional (Dry
battery or rechargeable battery optional).
The balance consists of analogue to digital conversion, microprocessor control,
power supply, keyboard, and a weight display contained within a single enclosure.
3.1 Display
The approval XE model is equipped with auxiliary display (for 600g and 6000g
products) or extended display (for other mode).
Note: When XE connecting with a remote display use in commercial transaction,
neither the auxiliary display nor the extended display function is permitted (control
by CAL mode)
Display after power on
The display first shows “CAS XE” to indicate its model when power on.
Then it shows the software version.

10
Then the balance displays NON-RC or RC to distinguish the scale is applied to use the dry
cell or rechargeable battery.
Then it starts to count down for self-testing and return to zero.
3.2 Keypad design

11
Keypad description
KEYS FUNCTIONS
ON/OFF:
To power on or off the scale.
MODE/MEMU-CLEAR:
To switch the application mode to be weighing mode,
counting mode, percentage weighing mode or density
measuring mode;
Long press to enter into User Menu setting
To clear the inputted numeric values.
UNIT/SAMPLE-BACK:
To switch the available units.
To take sample in counting or percentage weighing
mode;
To back to last step during parameters setting.
ZERO/▶-F1:
To return the display to zero.
To move the digit to the right;
IR function (Zero)
TARE/▲-F2:
To subtract the tare weight;
To decrease the number or move to last choice.
IR function (Tare)
A/1d/10d-▼:
To average the unstable weight readings and get one
reading as the displayed value (3 seconds)
Long press to extend or auxiliary the display.
To increase the number or move to next choice.
PRINT/ENTER-F3:
To print the data;
To confirm the choice in setting;
Long press to switch the backlight mode.
IR function (Print)
Questo manuale è adatto per i seguenti modelli
4
Indice
Altri manuali CAS Scala

CAS
CAS PD-II Manuale utente

CAS
CAS LP-II Manuale utente

CAS
CAS SW-1S Series Manuale utente

CAS
CAS Atronics ACS Manuale utente

CAS
CAS CL5000J Series Manuale utente

CAS
CAS PR-T Series Manuale utente

CAS
CAS NC-1 Manuale utente

CAS
CAS SW-1S Series Manuale utente

CAS
CAS DB-1H Manuale utente

CAS
CAS SC-05P Manuale utente