CEMB TR-NC/8 Guida utente

Vibration equipment division
www.cemb.com
CEMB S.p.A.
Via Risorgimento, 9
23826 MANDELLO del LARIO (Lc) Italy
TR-NC/8
No-CoNTaCT TRaNsmiTTeR
Use aNd maiNTeNaNCe iNsTRUCTioN maNUal
*Translation of the original instructions


Vibration equipment division
TR-NC/8 - Rev.02/2013
General Index
1. General descrIptIon 3
1.1 SyStem compoSition 3
2.
operatInG prIncIple and typIcal applIcatIons 4
3. specIfIcatIons 5
4.
rules for proper InstallatIon 7
4.1
Wiring and poWer Supply 7
4.2
maximum loop load in relation to the poWer Supply voltage 7
4.3
connection diagram 7
4.4
material of the area the SenSor faceS 8
4.5 SenSor poSitioning 8
4.6 Quality of the Surface the SenSor faceS 9
4.7 runout 9
4.8 deviceS for SenSor inStallation 10
5. I
nstallatIon 11
5.1 F
inal poSitioning 13
5.2
general ruleS for proper electrical inStallation 13
5.2.1 ElEctrical cabinEt 13
5.2.2 Wiring 14
5.2.3
cablE shiElding 15
5.2.4 Earthing 15
5.2.5 T
roublEshooting 15

TR-NC/8 - Rev.02/2013

Vibration equipment division
3
TR-NC/8 - Rev.02/2013
1. General descrIptIon
Monitoring vibrations of machinery in operating conditions allows examining the trend of the vibrations over time, predicting
which part will start to deteriorate rst and planning maintenance so as prevent production stops because of serious faults
and the consequent economic losses.
Rarely does a vibratory phenomenon develop over time according to linear or known laws; sometimes it increases gradually,
as in the case of wear, other times rapidly, as in the case of faulty lubrication, or it occurs suddenly and severely, as in the
case of breakage of turbine blades.
You can act timely to prevent major damage caused by high vibrations only by continuous monitoring using instruments
equipped with alarm and locking devices that are activated when vibration exceeds preset safety limit values.
Vibration is monitored by means of a sensor facing the rotor in correspondence to the measuring point and a cable connect-
ed to a signal power and processing board.
Initially designed and developed for monitoring steam turbines of large thermoelectric power stations (where they are of vital
importance), continuous monitoring instruments (whose cost has come down considerably) have proved to have manifold
application possibilities and usefulness in the most varied industrial plants, wherever there are high-end machines that need
to be highly accurate and maintained such over time, or auxiliary machines (fans, pumps) whose failure would cause pro-
duction stops with the resulting economic losses.
The transmitter operates with a current loop of 4-20 mA and, depending on the model, has a current output proportional to
the distance between the sensor and the target (displacement measurement), the target vibration (vibration measurement)
or the gearwheel rotation speed (speed measurement).
1.1 system composItIon
The TR-NC8 measuring system is made up of three parts:
• T-NC8/API series no-contact sensor
• T-NC/API series extension cable
• TR-NC8 transmitter
No-contact sensor Extension cable

4
TR-NC/8 - Rev.02/2013
The total length of the cable between the sensor and the transmitter represents an “electrical length“, which means that
each system is calibrated in the CEMB laboratory for a specic total cable length, consequently, any change in length on a
pre-calibrated system will give rise to measurement errors.
The total length of the sensor-transmitter connection must therefore be dened in advance based on the installation require-
ments.
Transmitter
The transmitter provides the measuring signal on a current loop of 4-20mA as well as a voltage signal proportional to the gap
for evaluation of correct sensor positioning.
The electronics is contained in a casing and encapsulated in a special resin.
2.
operatInG prIncIple and typIcal applIcatIons
The inductive eddy current type sensors operate by generating a high-frequency electromagnetic eld, which in its turn
generates induced eddy currents in the target. The induced eddy currents generate an impedance variation in the sensor,
which, measured and linearised by dedicated electronics, is converted into a signal proportional to the distance from the
target. The target must necessarily be made of a conductive material and variations in material would produce measurement
differences, which is why the transmitter is calibrated for a specic material.
Typically the sensor faces a piece of ferrous material; anisotropy of the rotor material, chrome-plating, surface roughness,
etc. may cause signicant errors.
The typical applications of the device are:
• Measurement of relative vibrations between the shaft and the bearing in systems where continuous monitoring is re-
quired, also in the most severe operating conditions.
• Monitoring of displacement of a metal surface, also moving (e.g. axial or differential displacement measurements).
• Speed measurement on a gearwheel
The transmitter provides an output on a current loop of 4-20mA proportional to the parameter measured and can be connect-
ed to dedicated PLC or DCS acquisition boards.

Vibration equipment division
5
TR-NC/8 - Rev.02/2013
3. specIfIcatIons
Basic composition sensor, extension, transmitter
Type of measurement differential
Measurement range ± 1 mm (0,5÷2,5 mm)
Dynamic range
frequency 0÷500 Hz (displacements)
frequency 1.5÷10.000 Hz (vibra-
tions)
Output signal 4-20mA loop + analogue gap
Linearity over the entire measurement range and
within the operating temperature limits indicated ± 1%
4-20mA output scale factor according to order code
GAP + BNC scale output factor 100 mV/mil (3.94 mV/µm)
GAP + BNC centre scale output 5.00VDC
GAP + BNC scale start output 1.07VDC
GAP + BNC scale end output 8.94VDC
Sensitivity to temperature according to ANSI/API 670-93
Power supply 24VDC nominal
Operating range
temperature (sensor)
temperature (transmitter)
humidity (sensor)
humidity (transmitter)
= - 35 to + 175° C
= - 20 to + 70° C
= max 100%
= max 95% (non condensing)
Sensor connection miniature coaxial connector
(sensor / transmitter)
Output connections
4-way screw terminal board
(transmitter / instrument)
BNC for analyser connection
Transmitter weight ~ 1 Kg
Sensor weight ~ 0,1 Kg
Maintenance none
Special versions
ATEX certied version
for applications in classied areas
II 1 G Ex ia IIC T5 Ga
II 1 G Ex ia IIC T6 Ga

6
TR-NC/8 - Rev.02/2013
3,000
4,000
5,000
6,000
7,000
8,000
9,000
10,000
0,00
4,00
8,00
12,00
16,00
20,00
24,00
0,00 0,20 0,40 0,60 0,80 1,00 1,20 1,40 1,60 1,80 2,00
Sensibilità [mA/mm]
Corrente [mA]
Distanza [mm]
TR-NC/8 -LOOP
Corrente [mA]
Sensibilità [mA/mm]
8.00mA/mm ±5%
3,000
3,200
3,400
3,600
3,800
4,000
4,200
4,400
4,600
4,800
5,000
0,00
1,00
2,00
3,00
4,00
5,00
6,00
7,00
8,00
9,00
10,00
0,00 0,20 0,40 0,60 0,80 1,00 1,20 1,40 1,60 1,80 2,00
Sensibilità [V/mm]
Tensione [V]
Distanza [mm]
TR-NC/8 -GAP
Tensione [V]
Sensibilità [V/mm]
3.94V/mm ±5%
3.1 T
ypIcal characterIstIc curves

Vibration equipment division
7
TR-NC/8 - Rev.02/2013
0
100
200
300
400
500
600
700
16 18 20 22 24 26 28 30 32 34
Max load [Ohm]
Power supply [V]
LOOP
SUPPLY
AND
MEASURE
(PLC or DCS)
MEASURE
LOAD
CABLE
LOAD
RESISTANCE
+24Vdc
4.
rules for proper InstallatIon
Measurements made using no-contact sensors that exploit the eddy current principle may be compromised or falsied by a
series of phenomena or parameters which should be taken into consideration when designing the monitoring system.
4.1
WIrInG and poWer supply
The monitoring instruments require an external power supply which should as directly as possible branch off from a reliably
efcient source also in cases of emergency of the main electric systems.
Power supply from a low-voltage network used for other instruments should be avoided, as their failure might place the aux-
iliary supply network out of service and hence also the monitoring instruments.
If the power supply is necessarily centralized for various instruments, suitable devices should be installed so that failure of a
single instrument or amplier or transmitter cannot affect the power supply to the other instruments.
Use a bipolar shielded cable; the cross-section of the conductors is related to the distance between the transmitter and the
acquisition system. If the distances are considerable, take into account the sum of the voltage drops on the load and on the
cable, which must ensure proper power supply to the transmitter. The nominal supply voltage is 24 VDC. The transmitter
can also measure correctly with a voltage between 24 and 35 VDC, guaranteeing a maximum loop load value (sum of the
measurement resistance plus the cable resistance) as shown in the graph below.
4.2
maxImum loop load In relatIon to the poWer supply voltaGe
4.3
connectIon dIaGram

8
TR-NC/8 - Rev.02/2013
4.4
materIal of the area the sensor faces
Although the sensor can face any ferromagnetic material, it should however be considered that the sensitivity and linearity
of the measurement range very much depend on the chemical properties of the material.
Unless otherwise requested, the measuring system is calibrated in the CEMB laboratories using AISI 4140 stainless steel
(42CrMo4) as reference material, which is normally used in the construction of machine shafts.
4.5 sensor posItIonInG
The magnetic eld generated by the sensor is propagated in all directions, therefore, if there are other electrically conductive
materials in this eld (known as sensor reference cone), the measurement result will be affected.
For this reason, when installing the sensor in the machine, the following conditions need to be observed:
► Free space around the sensor
► Minimum shaft diameter
► Distance from the shaft shoulders
► Distance between sensors
Indice