POCKET ANALOG MULTIMETER


GENERAL DESCRIPTION
INTRODUCTION
This meter is a rectifier type, permanent-magnet moving coil
instrument for measuring DC voltage, AC voltage, DC current ,
resistance, decibels and for testing battery strength.
1. Pointer
2. Zero set control
3. 0adjuster knob
4. Selector switch
5. "-" jack
6. "+" jack
7. Scale
1
2
3
4
56
Figure 1
7
2
INTRODUCTION

3
model no. 052-0059-8 | contact us 1-800-689-9928
WARNING
SAFETY INFORMATION
WARNING
The meter has been designed according to IEC-61010 concerning
electronic measuring instruments with a measurement category
III ( CAT III 300V ) and pollution degree 2.
To avoid possible electric shock or personal injury, follow these
guidelines:
Do not use the meter if it is damaged. Before you use the
meter, inspect the case. Pay particular attention to the
insulation surrounding the connectors.
Inspect the test leads for damaged insulation or exposed
metal. Check the test leads for continuity. Replace damaged
test leads before you use the meter.
Do not use the meter if it operates abnormally. Protection may
be impaired. When in doubt, have the meter serviced.
Do not operate the meter around explosive gas, vapour, or dust.
Do not apply a voltage or current higher than the selected
range's upper limit between terminals.
Before use, verify the meter's operation by measuring a known
voltage.
connecting the meter to the circuit. Remember to place the
meter in series with the circuit.
When servicing the meter, use only specified replacement
parts.
Use caution when working with voltage above 30 V AC RMS,
42 V peak, or 60 V DC. Such voltages pose a shock hazard.
a.
b.
c.
d.
e.
f.
g.
h.
i.

4
WARNING
When using the probes, keep your fingers behind the finger
guards on the probes.
Connect the black test lead before you connect the red test
lead. When you disconnect test leads, disconnect the red test
lead first.
Remove the test leads from the meter before you open the
battery cover or the case.
Do not operate the meter with the battery cover or portions
of the case removed or loosened.
To avoid electric shock, do not touch any naked conductor
with hand or skin, and do not ground yourself while using the meter.
Remaining endangerment:
When an input terminal is connected to dangerous live
potential it is to be noted that this potential at all other
terminals can occur!
CAT III
−
j.
k.
l.
m.
n.
o.
p.
Measurement Category III is for measurements performed
in the building installation. Examples are measurements on
distribution boards, circuit breakers, wiring, including
cables,bus-bars, junction boxes, switches, socket-outlets in the
fixed installation, and equipment for industrial use and some other
equipment, for example, stationary motors with permanent
connection to the fixed installation.
Do not use the meter for measurements within Measurement
Categories IV.

5
model no. 052-0059-8 | contact us 1-800-689-9928
CAUTION
CAUTION
ELECTRICAL SYMBOLS
To avoid possible damage to the meter or to the equipment under
test, follow these guidelines:
Disconnect circuit power and discharge all capacitors before
testing resistance and continuity.
Use the proper function and range for your measurements.
Before rotating the selector switch to change functions,
disconnect test leads from the circuit under test.
Remove test leads from the meter before opening the battery
cover or the meter case.
Alternating Current
Direct Current
DC or AC
Caution: risk of danger. Refer to the operating manual before use.
Caution: risk of electric shock.
Earth (ground) Terminal
Fuse
Conforms to European Union directives
The equipment is protected throughout by double insulation
or reinforced insulation.
a.
b.
c.
d.

6
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION
Measuring Range
DC Current: 0.6/12/600 mA
Accuracy at FSD: 5%
DC Voltage: 3/12/60/120/300 V
Accuracy at FSD: 5%
AC Voltage: 12/60/120/300 V
Accuracy at FSD: 5%
Resistance: × 10 ( scale centre at 50 )
× 1k ( scale centre at 5 k)
Accuracy: 5% of arc
Battery Test: 1.5 V
9 V
Decibel: -20 to 50 dB
Sensitivity: 2000 /V DC and AC
Operating Environment: 32 to 104°F (0 to 40°C),
relative humidity < 85%
Storage Environment: 32 to 122°F (0 to 50°C),
relative humidity < 85%
Size: 4 1/2 x 2 3/4 x 1 5/16" (115 x 70 x 34 mm)
Weight: about 6 oz (181 g) ( including battery )

7
model no. 052-0059-8 | contact us 1-800-689-9928
INSTRUCTION
There are five scales:
The upper scale is for resistance measurements.
The second scale " " is for the measurements of DC voltage,
AC voltage ( except AC 12 V range ), and DC current.
The third scale is only for AC voltage measurements of the AC
12 V range.
The fourth scale "dB" is for decibels.
The fifth scale "BATT" is for battery test.
SCALE INSTRUCTION
Figure 2
Common Markings
for Voltage and
Current Scales

8
OPERATING INSTRUCTIONS
Points to be Observed before Operation
Before measuring, check the pointer to see whether it
exactly rests at the "0" position, and if not, adjust the
pointer with the zero set control ( Figure 3 ).
Insert the red test lead to the "+" jack and black test lead
to the "−" jack.
If the magnitude of the voltage or current to be measured is
not known beforehand, always set the selector switch to
the highest range, and then work down to an appropriate
range in order to avoid damage to the meter.
Don't touch any conductor with hand or skin to avoid
electric shock.
OPERATING INSTRUCTION
Figure 3
A.
1.
2.
3.
4.
The pointer exactly
rests at the "0" position.
Zero set control

9
model no. 052-0059-8 | contact us 1-800-689-9928
OPERATING INSTRUCTIONS
DC Voltage Measurement
Set the selector switch to the desired " V " range.
Connect the test leads across the circuit to be measured.
Note: The black test lead must be connected to the
negative potential of the circuit; the red test lead must
be connected to the positive potential of the circuit.
If the pointer deflects to the left of the scale, reverse
the test leads.
Use the chart below as a guide to reading DC voltage measure-
ments:
DC V Read and
Range Following Multiply
Setting Scale Reading By:
B.
1.
2.
3.
AC Voltage Measurement
Set the selector switch to the desired " V" range.
Connect the test leads across the circuit to be measured.
If the selector switch is in 12 V range position, reading is
taken from the third scale " AC 12 V".
If the selector switch is in 60 V, 120 V, or 300 V range
position, reading is taken from the second scale " ".
Use the chart below as a guide to reading AC voltage
measurements:
C.
1.
2.
3.
3
12
60
120
300
0 - 300
0 - 12
0 - 60
0 - 12
0 - 300
Divide Reading by 100
1
1
10
1
Indice
Manuali Multimetro popolari di altre marche

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Manuale utente

PeakTech
PeakTech 4000 Manuale per l'uso e la cura

YOKOGAWA
YOKOGAWA 90050B Manuale utente

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Manuale utente

Fluke
Fluke 8846A Manuale operativo e di manutenzione

Tempo Communications
Tempo Communications MM200 Manuale utente