Page 3 of 28 ALX-ELITE Manual V1.1 Last Update: 04/03/2017
USER MANUAL: ALX-ELITE
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
GeneralInstallaonConguraonAppendices Operaon
Troubleshoong General
The ALX-ELITE is a chemical management
controller that can dispense chemicals according
to programmable recipes (Applicaons). Access to
Applicaons can be restricted on a per-user basis over
a rolling me period. Users can be required to use
a 4-digit login passcode or RFID card to login before
dispensing Applicaons. This allows tracking and
recording of chemical usage by User. The ALX-ELITE
will generate and e-mail Reports on demand or on
a daily, weekly or monthly basis. Reports can also
be downloaded to a USB ash drive for immediate
viewing. All conguraon of the ALX-ELITE can be
performed using the built-in keypad and character
display. The ALX-ELITE will also broadcast a local WiFi
network which allows access to the web-browser
based System Editor for conguraon using a laptop.
Overview
Soware
• Maximum number of Users: 999
• Maximum number of Applicaons: 999
• Maximum Dispense Steps per Applicaon: 6
• Dispense Step me range: 00.1s - 99m:99.9s
• Permissions me range: 1-24 hours
• Max Permissions count: 99
Hardware
• Maximum number of Devices: 16*
• Dimensions: 12" x 10" x 7"
*NOTE: A single CAN-SO-4 counts as 4 Devices
Acceptable Chemical Products
• Acids
• Causcs
• Sanizers
• Chlorine
Specicaons
Terminology
• Users - The people who will be using the system
to dispense Applicaons. Up to 999 users can be
stored.
• Permissions - Control the number of mes
each User can access each Applicaon. Can be
disabled.
• Devices - The physical outputs and/or inputs that
connect to the controller to perform a funcon.
The ALX-ELITE is compable CAN-SO-1 and CAN-
SO-4 solenoid valve output devices.
• Applicaons - Recipes which determine the type
and sequence of Dispense Steps. Up to 999
recipes can be stored.
• Dispense Steps - Segments of an Applicaon that
determine which output Device will be energized
and for how long. Each Applicaon can contain up
to 6 Steps.
• Fixed Time Step - Will energize an output Device
for a specied amount of me. Reported Step
volume must be manually entered.
• Calibrated Step - Uses Device Calibraon to
determine how long an output Device should be
energized, based on a specied target volume.