BLX-200W Manual Page 7 of 9 Updated: 02/11/21
USER MANUAL: BLX-200W
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
GeneralInstallaonOperaonAppendix
General Use
Prior to use - ensure brushes, handrail, and foot plates
are secured and the system itself properly installed.
To verify water/sanizer supply; step on the Foot
Plate to iniate water/sanizer ow. Before operang
the unit, ensure solid foong and use both hands on
the handrail for support.
1. To begin operaon, step up to the unit and grip
the support handrails.
2. Enter the unit from either end, placing one boot in
the brush secon and the other on the opposing
foot plate to acvate the spray system.
3. Push the boot back and forth mulple mes so
every part makes contact with the brushes.
4. Once the rst boot is clean, remove it and walk
through to the second scrubber and repeat the
process with the other boot.
5. If boots are extremely dirty, it may be necessary to
scrub them mulple mes.
Cleaning and Wash-Down
1. Shut o water supply to unit and depressurize
water lines.
2. Remove the Foot Plates and brushes from the
unit.
3. Brushes and Foot Plates can be washed,
individually, in a COP tank, or wash machine.
4. The frame can be washed down by convenonal
means.
Operaon
The following maintenance procedures are
recommended for normal use. Units which see a
high amount of daily use should be inspected more
frequently as necessary.
Weekly:
• Inspect brushes for damage or wear.
• Check for missing or deformed bristles.
• Inspect plumbing/water lines for damage
• Ensure solid mounng to oor.
Monthly:
• Check all fasteners to ensure they are ght.
• Ensure warning labels and decals are present
and in good condion.
• Inspect valve for damage
Quarterly:
• Inspect structure for cracked welds or bent
components.
Maintenance