Read these instructions carefully before you start using the circulator-fan and keep the manual for later usage.
Circulator-fan with ionizer Clean Air Optima® CA-404W
© Copyright: Clean Air Optima
®
Manual

2
CA-404W
English
Thank you for purchasing the Clean Air Optima®Circulator-fan with ionizer CA-404W.
We wish you many years to have a pleasant room climate and healthy indoor air with this
ecient and eective Clean Air Optima® product.
These instructions describe the safety precautions to be observed during operation. They are
meant to prevent injuries and to avoid damaging the device.
Description of the device
The device consists of the following main components:
1. Removable protection grid
2. Protection grid cover
3. Protection grid decoration net
4. Protection grid rear
5. Foldable stand
6. Foldable stand cover
7. Steppless speed swicht knob
8. Digital display
9. Top of the housing
10. Housing
11. Foot

3
Safety warnings
This device may only be used in accordance with these safety instructions. Take the following
steps to minimize the risk of personal injury caused by for example electric shocks or fire.
1. Only for indoor use. Do not use or store outdoors.
2. Use proper voltage: AC 220V - 240V, 50Hz
3. Make sure that the air outlets are always free, clean up dust, hair and other obstruction for
the airflow and at the air outlets.
4. Keep your hair, clothes, jewels or fingers away from the air outlets.
5. The device is not intended to be used by children or persons with reduced physical-,
sensory- or mental capabilities, unless they are supervised by a person responsible for
their safety.
6. Children should be kept away unless continuously supervised.
7. To safely use the device, put it in a steady, horizontal position. Do not move while using.
8. Do not use the device when there is visible damage on the electrical cord or on the device
itself. Do not repair the device yourself in case of damage. Never pull the device by its cord.
If the power cord is damaged, then it must be replaced by an authorized service person to
prevent electric shock or fire.
9. Repairs may only be performed by authorized service personal. Do not try to repair the
device yourself to prevent electric shock or fire.
10. Always remove the plug from the socket when the device is not being used or when you
clean internal or external parts of it.
11. Do not use the device in rooms where inflammable liquids or gases are stored, close to
heat sources or in particularly humid rooms like the bathroom, shower or swimming pool.
12. To prevent malfunctions, never insert strange objects into the device.
13. Never dissemble or replace the device’s inner parts.
14. Do not place the device in direct sunlight, to avoid that the device discolours.
15. Never immerse the unit in water or other liquids.
16. Do not touch the power cord with wet hands.
17. Clean the device before storage. Store the machine in a cool and dry place outside
the reach of children.
18. Do not ingest the battery, the battery is a Chemical Burn Hazard.
19. This device contains a coin / button cell battery. If the coin / button cell battery is
swallowed, it can cause severe internal burns in just 2 hours and can lead to serious
complaints or decease.
20.Keep new and used batteries away from children.
21. If the battery compartment does not close securely, stop using the device and keep it away
from children.
22.If you think batteries might have been swallowed or placed inside any part of the body,
seek immediate medical attention.
23.The batteries contain materials, which are hazardous to the environment, they must be
removed from the device before it is scrapped and that they are disposed safely.
24.Use, maintain and clean the device as described in this manual.

4
Features
1. Stepless Speed Switch Knob with 24 speed levels.
2. Timer function 1 - 12 hours.
3. Remote control function.
4. Negative ion >3.000.000 /cm³.
5. Oscillation function, automatic swing in horizontal direction up to 80°; manual swing
in vertical direction up to 180°.
6. Sleep Air Flow mode.
7. The display led lights will automatically turn o after 1 minute of use and or inactivity
of the display.
8. Foldable for easy storage.
9. Uninterruptible power memory function.
10. Dynamic Natural Air Flow
Installation and Operating instructions
The package contains: circulator-fan, remote control and instruction manual.
Assembling the device
1. Take out the device from the package.
2. Carefully put the device on a stable surface.
3. The device needs to be positioned at least 20 cm from a wall.
Operating Functions
Plug in the device: you will hear an acoustic sound “Bi, Bi”.
ON/OFF button
Press the button, the circulator-fan starts working. Press it again, the device turns o.
Steppless Speed Switch Knob
Turn the switch knob to the right to increase the wind speed levels. The digital display
will show the corresponding wind speed level. If you continue to rotate to the right you will
reach an maximum wind speed level of 24 and you will hear the acoustic sound “Bi”. Rotate the
switch knob to the left to decrease the wind speed level. If you continue to rotate to the
left you will reach an minimum wind speed level of 1 and you will hear the acoustic sound “Bi”.
Dynamic Natural Air Flow
Press the button, to turn on the Dynamic Natural Air Flow mode, the digital display will
show level 8. Use the switch knob and rotate to the right to switch to level 16 and 24 or
switch back to 16 and 8 by rotating the switch knob to the left.

5
24 levels are divided into three groups
1 – 8 low level = level 8 on display
9 – 16 middle level = level 16 on display
17 – 24 high level = level 24 on display
The wind speed levels in 8, 16 and 24 are preprogrammed for the Dynamic Natural Air Flow,
the circulator-fan will operate according to the diagram below:
Press again to turn o the Dynamic Natural Air Flow mode.
Sleep Air Flow
Press the button, to turn on the Sleep Air Flow mode, the digital display will show level 6.
The wind speed levels can be adjusted from level 6 to level 1 with the switch knob by
rotating to the left. When operating for example in Sleep Air Flow mode level 6, the wind speed
will be reduced by one level (6 to 5, 5 to 4, 4 to 3, 3 to 2, 2 to 1, 1 = continuous) every 30 minutes.
Press again to turn o the Sleep Air Flow mode.
Timer
Pressing the button, sets the timer. The timer function determines how many hours the
circulator-fan will operate. You can set the timer simply by turning the switch knob to the
right or left and the digital display will show the selected time you would like to run the device.
The timer can be set from 1 hour to 12 hours. As time passes, the time value decreases until it
goes to 00:00 hours and the device shuts o.

6
Press again to turn o the Timer function.
80° Oscillation
Pressing the button, sets the 80° automatic oscillation. The circulator-fan will oscillate to
the right angle of 45° and to the left angle of 45°.
Press again to turn o the 80° Oscillation function.
Negative Ion
Pressing the button, will activate the negative ion generator with a total capacity of
> 3.000.000 negative ions / cm³that are spread from the fan air flow through out the entire
room and thereby neutralize pollutants and smells. Negative ions attach onto dust particles,
microorganisms and other unwanted particles in the air and connect them to each other.
This way, the particles become heavier than air and fall onto the ground so that you can no
longer breathe them in.
Negative ions are most found in the forest, mountains and by the sea. Negative ions ensures
fresh and healthy air.
Press again to turn o the Negative Ion function.

7
Remote control
The buttons on your remote control:
1. ON/OFF
2. Timer
3. 80°oscillation
4. Program setting
5. Wind speed level 1-24
6. Negative ion
Replacing batteries in the remote control
1. Open the battery cover at the back side of the remote control to place the battery.
(see picture 1).
2. To place the battery: there is a “security tab” at the bottom of the remote control that you
first have to slide to the right and then pull out the battery holder. (see picture 2).
Insert the battery with the correct polarity. (see picture 3).
3. Push the battery cover back into the remote control.
Remote control Battery cover
Picture 1 Picture 2
Picture 3 Battery (CR2025)

8
Cleaning and maintenance
1. Before cleaning the device, unplug the power cord.
2. Clean the housing with a soft moisture cloth. Do not use chemical solvent (such as benzene,
alcohol, gasoline). The surface may be damaged or even the whole case may be deformed.
The circulator-fan has an detachable front for easy cleaning (see picture 1).
Use a Philips-head screwdriver and remove the screw from the rear protection grid
(see picture 2). Then turn the detachable front on the front side a quarter to the left and
take out the grid.
You can now remove dirt and dust from the blades with a soft moisture cloth (see picture 3).
3. Do not sprinkle water on the device.
4. If the circulator-fan is not used for a longer period of time, we advise to clean the device
carefully and let it dry. The device has to be stored in a cool and dry place.
Picture 1 Picture 2
Picture 3

9
Troubleshooting
The following is a troubling shooting guide to help you solve any issues that you may have
using the Clean Air Optima®Circulator-fan CA-404W
Problem Possible Cause Solution
Device does not
switch on
Power plug not plugged in
ON / OFF button not activated
Plug in device
Press ON / OFF button
Device is noisy
There may be too much dust
on the device/fan blades
The device is on an unstable
surface
Clean the device and fan blades
Place the device on solid and
even ground
The remote control
does not work
Check if the battery
is installed
Check if the battey
is in-stalled correctly
Check the capacity
of the battery
Check the remote control
distance exceeds the range
Install the battery
Install the battery correctly
Replace te battery
Range is within 5 meters from
the front-side of the device

10
WARNING!
If the above recommended solutions do not work, please contact Clean Air Optima®technical
support at the telephone number for your region. Do not attempt to disassemble, reassemble,
or repair the device as this may void the warranty.
Specifications
Model CA-404W
Rated voltage 220V - 240V, 50Hz
Rated power 25W
Noise level < 10dB(A) (Speed 1)
≤55dB(A) (Speed 24)
Airflow 660m³/H
Turning circle Horizontal 80°Automatic oscillation
Vertical 180°Manual rotation
Dimensions 240 x 240 x 345 mm
Weight 2,1 kg
Colour White with black front cover
Carried standard IEC/EN 60335-1 IEC/EN 60335-2-80 IEC/EN 62233:2008
Complies with EU
regulations CE / WEEE / RoHS