Clearfield FieldSmart FAC 3200 Manuale utente

FieldSmart®Fiber Active Cabinet (FAC) 3200
Installation Manual ______________________________________________________
Manual 020421 REV A - Jan 2019

Proprietary Information: Not for use or disclosure except by written agreement with Cleareld.
2
FieldSmart®Fiber Active Cabinet (FAC) 3200
Installation Manual _________________________________________________________
Table of Contents
About This Guide 5
Chapter 1: Fiber Active Cabinet 3200 Product Overview 6
Cabinet Description 7
Cabinet Features 8
Cabinet Options 9
Cabinet Dimensions and Weights 10
Cabinet Views 11
Chapter 2: Installation Considerations 14
Installation Process Overview 15
Installation Guidelines 16
Space Requirements 17
General Safety Recommendations 18
Installation Kit 19
User-Supplied Items 20
Cabling Requirements 21
Chapter 3: Preparing the Installation Site 22
Installing a Ground Circuit 23
Constructing a Concrete Pad 25
Pad Construction Guidelines 25
Assembling the Cast-In-Place Template 28
Preparing the Site 30
Casting the Pad 31
Installing a Pre-Cast Concrete Pad 32
Pre-Cast Pad Requirements 32
Preparing the Site 35
Installing a Pre-Cast Pad 36
Installing a Pole-Mount Kit 37
Pole Mounting Guidelines 37
Preparing the Site 40
Installing the Pole-Mount Kit 41
Installing a Wall-Mount Kit 44
Wall Mounting Guidelines 44
Preparing the Site 47
Installing the Wall-Mount Kit 48

3
FieldSmart®Fiber Active Cabinet (FAC) 3200
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 020421 REV A - Jan 2019
Chapter 4: Installing the Cabinet 51
Unpacking the Cabinet 52
Operating Cabinet Doors 53
Preparing the Cabinet for Installation 55
Installing the Cabinet on a Concrete Pad 56
Installing the Cabinet on a Pole 58
Installing the Cabinet on a Wall or H-Frame 60
Replacing the Lifting Eye Bolts 62
Chapter 5: Installing Power 63
Installing the Cabinet Ground Connection 64
Installing AC Power (220-240 VAC) 65
Installing AC Power (110-120 VAC) 66
Chapter 6: Installing and Splicing Outside Plant Cables 69
Installing Fiber Cables 70
Installing Outside Plant Fiber Cable 70
Splicing Fibers 72
Routing and Terminating Fibers 73
Installing Metallic Cables 74
Installing Outside Plant Metallic Cables 74
Splicing Metallic Cables 76
Installing 5-Pin Protection Modules 77
Sealing Cable Entry Locations 78
Chapter 7: Turning Up the Cabinet Power System 79
Checking the Ground Connection 80
Checking the AC Power Supply Voltage 81
Installing Rectier Modules 83
Installing Batteries 85
Turning Up and Testing the DC Power System 87
Chapter 8: Installing Equipment and Adding Capacity 89
Installing a Protection Mounting Frame 90
Installing a Protection Block 91
Installing a Battery Compartment Riser 93
Installing a Battery Heater 95
Installing an AC Meter 96
Installing a Generator Connector 97

Proprietary Information: Not for use or disclosure except by written agreement with Cleareld.
4
FieldSmart®Fiber Active Cabinet (FAC) 3200
Installation Manual _________________________________________________________
Installing a Fiber Termination Assembly 100
Installing a PON Splitter Assembly 102
Connecting PON Splitter Fibers 104
Connecting AE Fibers 105
Connecting Transport Fibers 106
Installing Fiber Patch Cords 108
Chapter 9: Cabinet Maintenance 109
Routine Maintenance 110
Checking Electrical Components 110
Checking Cabinet Surfaces 110
Checking Cable Connections 111
Battery Maintenance 112
Replacing Parts and Equipment 114
Removing a Cabinet Door 114
Installing a Cabinet Door 115
Replacing AC Breakers 117
Replacing DC Breakers and Fuses 118
Replacing Rectier Modules (for optional Valere Rectier)
119
Replacing Batteries 121
Replacing a Battery Heater 122
Appendix A: Reference Information 123
Specications 124
Supported Batteries 125
Rack Space for Additional Equipment 125
Valere Rectier Alarm Matrix 126
Valere Rectier Setpoints 127
Programming the Valere Shelf Controller 129
Rectier Module Usage Guidelines 131
Wiring Diagrams 131
Standard Warranty 132
Proprietary Notice 133
Technical Support 133

5
FieldSmart®Fiber Active Cabinet (FAC) 3200
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 020421 REV A - Jan 2019
About This Guide
Safety Notices
This document uses the following safety notice conventions.
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and
used in accordance with the instruction manual, may cause interference to radio communications. Operation of this equipment
in a residential area may cause harmful interference; the user will be required to correct the interference at his expense.
DANGER! Danger indicates the presence of a hazard that will cause severe personal
injury or death if not avoided.
WARNING! Warning indicates the presence of a hazard that can cause severe personal
injury if not avoided.
CAUTION! Caution indicates the presence of a hazard that can cause minor to
moderate personal injury if not avoided..
ALERT! Alert indicates the presence of a hazard that can cause damage to equipment,
damage to software, loss of data, or service interruption if not avoided.
DANGER! CLASS 1 LASER PRODUCT. INVISIBLE LASER RADIATION PRESENT.
Fiber optic radiation can cause severe eye damage or blindness. Do not look into the
open end of an optical ber.
Purpose
This document provides a general installation practice for the Cleareld FAC 3200 outdoor cabinet. This document also
provides a general description of the cabinet and its subsystems, and guidance for planning, site preparation, power
installation, splicing to the outside plant, component installation and expansion, and cabinet maintenance.
Intended Audiences
This document is intended for use by network planning engineers, outside plant engineers, eld support personnel, and craft
personnel responsible for cabinet installation, splicing, equipment installation, and maintenance.

Proprietary Information: Not for use or disclosure except by written agreement with Cleareld.
6
FieldSmart®Fiber Active Cabinet (FAC) 3200
Installation Manual _________________________________________________________
Chapter 1: Fiber Active Cabinet 3200 Product Overview
This chapter provides a general description of the Cleareld FAC 3200 outdoor cabinet, including its standard features
and options.
Topics Covered
This chapter covers the following topics:
• A description of the FAC 3200 cabinet.
• A list of cabinet features.
• A list of cabinet options.
• A view of the cabinet dimensions.
• Views of the cabinet compartments.

7
FieldSmart®Fiber Active Cabinet (FAC) 3200
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 020421 REV A - Jan 2019
Cabinet Description
The Cleareld FAC 3200 cabinet is an environmentally-controlled outdoor enclosure designed to house and protect network
electronics equipment. Use the FAC 3200 to provide network services from a remote node location, extending the service
area beyond the reach of the carrier Central Ofce.
The FAC 3200 cabinet supports high density ber and copper plant terminations, enabling deployment of a broad suite
of applications from a single node. The cabinet’s main electronics compartment is equipped with 23-inch front and rear
equipment racks that provide a total of 32 RU of mounting space.
The modular design of the FAC 3200 enables incremental eld expansion of system capacity, lowering initial deployment
costs while maintaining the capacity for future growth. Modular components designed for expansion include ber splicing
and distribution, copper line protection, and thermal management.

Proprietary Information: Not for use or disclosure except by written agreement with Cleareld.
8
FieldSmart®Fiber Active Cabinet (FAC) 3200
Installation Manual _________________________________________________________
Cabinet Features
Standard features of the FAC 3200 cabinet include:
Enclosure Design
• Environmentally sealed design protects from dust and water intrusion
• Compartmentalized for safety, including separate vented battery compartment
• Environmental and intrusion alarm systems
• GR-487 compliant and UL-60950/UL-50 spec
• Environmentally rated from -40C to +46C (per GR-487)
Equipment Support
• 23-inch front and rear equipment racks
• 32 RU total mounting space for equipment (16 RU per side)
• Mechanical support for high density ber and copper plant terminations
• Modular, scalable, up to 432 ber distribution capacity
Power (Local)
• 120/240 VAC load center (UL-listed); 60 Amp capacity
• AC service disconnect breaker
• AC surge suppressor (Joslyn)
• Redundant AC supplies to DC power system
• Convenience outlets (GFCI protected)
• Optional Valere compact DC power system (with distribution)
• Redundant DC supplies to equipment (A and B)
• Low voltage DC disconnect (-42V)
• Up to 170Ah battery reserve capacity (NSB 170FT); up to 340Ah capacity with second-string riser option

9
FieldSmart®Fiber Active Cabinet (FAC) 3200
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 020421 REV A - Jan 2019
Cabinet Options
Enclosure Mounting
• Concrete pad mounting (pre-cast pad or site-cast pad using Cleareld template)
• Pole mounting (using Cleareld pole-mount kit)
• Wall/H-frame mounting (using Cleareld wall-mount kit)
Power and Cooling
• 220/240 VAC input, recongurable for 110/120 VAC (requires 20A rectier modules)
• Generator connector (Hubbell); 30A
• N+1 rectier redundancy; 30A or 20A modules (20A only for 110/120 VAC input)
• Support for AC meter mounting
• Low-capacity (750W) or high-capacity (1850W) heat exchanger; door-mounted
Battery Support
• Battery heater kit
• Zone 4 seismic protection kit
• Battery compartment riser (supports a second battery string)
• Northstar (OEM) battery string and installation kit
Copper Protection & Splicing
• Copper line protection for up to 480 lines; MS2 or 710 interface connectors
• CAT3 or CAT5 interface cabling from the line protection blocks
• 2:1 URLS cross-connect (1000 subscriber/500 equipment pairs); MS2 interface connectors
Fiber Management
• Fiber distribution panel (1 RU); 12 or 24 positions (SC, LC, ST, FC connector options)
• 432 ber distribution vulkhead panel option; support for 12, 24, 48, 96 positions (SC, LC, ST, FC connector options)
Common options for the FAC 3200 cabinet include:

Proprietary Information: Not for use or disclosure except by written agreement with Cleareld.
10
FieldSmart®Fiber Active Cabinet (FAC) 3200
Installation Manual _________________________________________________________
Cabinet Dimensions and Weights
Conguration Weight (SAE) Weight (Metric)
480 lines (standard) 650 lb 295 kg
480 lines (cross-connect) 695 lb 315 kg
The external dimensions of the FAC 3200 cabinet are shown below.
Dimension Measurement (SAE) Measurement (Metric)
Height 54 inches 137 cm
Width 38 inches 97 cm
Depth 34 inches 86 cm
The approximate shipping weights of the FAC 3200 cabinet are shown below.
Indice
Altri manuali Clearfield Allegato