Table of Contents
Application 3
Description 3
Technical Specications 3
TAP Box Assembly 4
TAP Box Mounting 8
Cable Entrance 10
Grounding 11
Strength Member Clamp 11
Cable Routing 12
Connector Cleaning Procedure 13
Standard Warranty 16
Proprietary Notice 17
Technical Support 17

3
CraftSmart®Test Access Point (TAP) Box
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 020016 REV A - Sept 2018
Description
Application
Technical Specications
The CraftSmart Test Access Point (TAP) Box gives the service provider
an accessible exterior access point to test ber integrity before it enters
the customer premise. This solution allows the service provider the ability
to identify potential issues in conductivity from outside of the customer
premise location.
The CraftSmart TAP Box is a two part closure that will accommodate
up to four bers for test and access purposes. The base of the unit
will allow up to four splices from the feeder cable to individual drops
into the customer premise. Duplex SC adapters allow for installation
of pre-terminated or eld terminated ber to be connectorized for test
and access of the ber - to determine feeder and drop issues.
Two grommeted in/out ports on the bottom of the unit provide easy installation of both feeder and drop cables.
The unit is lockable to minimize customer tampering. There are grounding
options available inside the TAP Box
that will allow grounding of the feeder and drop cables. It also has built in access to exterior grounding built into the unit.
Multiple mounting options are available to meet all applications. The TAP box is available with private labeling on the
front cover to easily identify service provider’s identication.
CraftSmart Test Access Point (TAP) Box
Dimensions 7.3” H x 8.57” W x 1.67” D
Connector Availability/
Capacity
Empty: No connector
One dual SC/APC or SC/UPC; two dual SC/APC or SC/UPC; quad LC/UPC or LC/APC;
two quad LC/UPC or LC/APC
Cable Support and Tie Off
Options
Not included with TAP Box - MUST BE ORDERED SEPARATELY.
TAP-GL-KIT (one clamp per kit) Strength member tie off kit for at drop and dielectric cable
TAP-ARM-GL-KIT (one clamp per kit) Ground lug bracket for armored cable - no strength member tie off
Splice Capacity Four
Cable Entrance/Exit One on each port (two total). If using FieldShield® Microduct, order one FS-CPLR-10MM-10MM-TAP per exit
Private Labeling Standard: comes with Cleareld® logo.
Private labeling available (500 piece minimum). Contact Cleareld sales representative for details
Pre-terminated Feeder and
Drop Cable Available: Please contact your Cleareld sales representative
Mounting Options
Wall Mount: Standard
Vinyl Siding Mount: TAP-VS-KIT
Pole Mount: TAP-PM-KIT

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
4
CraftSmart®Test Access Point (TAP) Box
Installation Manual _________________________________________________________
Manual 020016 REV A - Sept 2018
TAP Box Assembly
The Tap Box will arrive as shown. Remove the cover by
sliding it off. Small parts will be contained inside, set them
aside.
TAP Box will appear as shown. You will need a side
cutters or pair of snips to remove the molded plastic
pieces attached at the base of the box.
Clip at the spots highlighted.
Proceed to clipping the pieces from the molding spur.
Pieces should include:
1. Large cable management retainers (Qty 4)
2. Duplex SC adapter holder
3. Bridge lances/cable tie downs (Qty 2)
4. Small cable management retainers (Qty 4)
2 431
1.
2.
3.

5
CraftSmart®Test Access Point (TAP) Box
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 020016 REV A - Sept 2018
Install the 4 large cable management retainers (round peg) into the top outside posts.
Install the 4 small cable management retainers (square peg) into the lower inside posts.
4.
5.

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
6
CraftSmart®Test Access Point (TAP) Box
Installation Manual _________________________________________________________
Manual 020016 REV A - Sept 2018
Using the supplied VHB tape, secure the two cable tie downs (bridge lances) into place inside the TAP Box. Tie down
locations exist above and below the splicing area. These will be used to secure the cable before splicing.
Snap the splice tray cover into place. If you plan to
splice inside the TAP Box later, the cover will protect the
splices.
6.
7.

7
CraftSmart®Test Access Point (TAP) Box
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 020016 REV A - Sept 2018
Place the adpater into the holder, and install it into the TAP Box at the top.
Note: If you are not utilizing the lower adapter slot of the
holder you may clip the piece to provide a path for cable to
run underneath.
8.
Trim the black cable entrance plugs, separating them. Place them into the entrances of the TAP Box. These can be
used to provide a weather seal around the cable. If utilizing microduct and a coupler (P/N FS-CPLR-10MM-10MM-TAP)
to bring cable into the TAP these may not be used.
9.

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
8
CraftSmart®Test Access Point (TAP) Box
Installation Manual _________________________________________________________
Manual 020016 REV A - Sept 2018
TAP Box Mounting
Wall Mount
The TAP Box can be mounted to a wall using standard
hardware and the provided holes
Mounting
holes
Vinyl Siding Mount
Siding clips (P/N TAP-VS-KIT) will be attached to the TAP
Box with 2 barbed push fasteners per clip. TAP can then be
hung from siding.

9
CraftSmart®Test Access Point (TAP) Box
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 020016 REV A - Sept 2018
Pole Mount
The Pole Mount Bracket (P/N TAP-PM-KIT) can be attached to many
different types of surfaces. Once attached, the TAP box can be secured
to the bracket with normal hardware and the 4 provided mounting holes.
4 x 4 Post
Tube Clamp - 3” Pipe U-Bolt - 3” Pipe
Sign Post

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
10
CraftSmart®Test Access Point (TAP) Box
Installation Manual _________________________________________________________
Manual 020016 REV A - Sept 2018
Cable Entrance
The TAP Box accepts a pushable ber quick connect coupler. The coupler can be zip tied into place and duct inserted into
the coupler. Cable can then be fed through the duct and into the TAP Box.
If not utilizing a coupler, cut two perpendicular slits in the center of the black cable entrance plug, and feed the cable through
the plug. Then wrap the cable with grommet tape (foam tape) below the plug and secure it into place on the TAP Box with a
zip tie. Insert the plug into place on the TAP just above.