Introduction
Thank you for purchasing this product.
To ensure proper operation, please read this manual carefully before
using the product.
After reading it, keep it in a safe place for future reference.
This product has been tested at our factory before shipping to you,
there is no assembly required.
Once after receiving this product, please take and put carefully. And
check cautiously that whether the product was damaged or not
during the transportation.
Checking Parts
Please check if the following parts are included:
2

1 x Light
1 x Power cable
1 x User manual
Danger Light Radiation!
Avoid direct eye exposure!
Light radiation can cause eye damage or skin damage
All protective measures for a safe operation of this light must
be applied.
Installation
1. Please check the voltage whether is the same with the one
showed on the equipment.
2. It must ask for the technical person and set the light safety when
installation. And let the light beam at the suitable angle.
3. When install this equipment please make sure there's no
flammable surfaces (decorated things, etc) within at least 2.5M and
maintain minimum distance of 0.5M from the equipment to the walls.
4. Please make sure that there's no other equipment or decorating
materials obstructed the exhaust fan and the vent-pipe.
5. Products should be install immobility.
6. In case of safety, it's very important that to connect ground wire.
Attention
1.Please do not open the bottom cover yourself without permission.
Operate it accord the user manual. Call the technician when the
machine breaks down.
2.Please do not see the light beam directly to avoid any damage.
3.Before connect or disconnect the power, please adjust the
luminance of the light diode to the least to avoid any damage to the
light diode.
4.This unit should be keep dry, do not use in the rain and dusty
environment. It can be use in the outdoor with the water-proof
cover .
5. Set the light immobility and try to avoid strong shake or hit.
6. Prevent dust into the equipment to avoid problems.
3

7. Please keep that there's no other equipment or decorating
materials obstructed the exhaust fan and the vent-pipe when the
equipment was working.
8. Before connect power, check the plug is immobility or not, power
cable should be connect well.
9. Please do not open or close the equipment frequently that's to
avoid any affect to the life span of the light diode, and try the best to
avoid the long time working.
10. Due to the characteristic of the light diode, after four hours
working, it should be close at least 25 minutes until the light diode
cooling then work again.
11. Don't touch the light or draw the power line when your hand was
wet. And do not pull the electronic power line.
12. Maintain the distance at least 3M above from the equipment to
the object.
13. This equipment does not have any parts can repair for the users,
please do not open the equipment.
14. When the light diode became dim or damaged please contact
the dealer timely.
15. When you want to re-transfer the product, you'd better use the
original package to shockproof.
LCD Function Menu
Menu
Secondary menu
DMX address
DMX address 001-512
Channel mode
14CH/35CH/42CH
Mode select
DMX512
Master
Slave 1
4

DMX Setting
Input DMX signal, DMX daisy chain picture as follow
DMX control, each light should has its own address. The fist light
address is 1, the second light address 15 or 36 or 43 (the first light
address 1 plus 14 or 35 or 42 channel), the third light address 29 or
71 or 85.
DMX - 512 control mode as following :
Slave 2
Auto Run mode
Auto 0-16
Speed 0-9
Sound mode
Show 0-16
Sound sense
0-100
Back lights
On/Off
Pan Inverse
Yes/No
Tilt Inverse
Yes/No
Auto Test
Test
Fixture Time
0-9999
Software Version
Version
Motor Reset
Yes/No
Default
Reset
5

Master-slave Setting
Link the lights as the following picture (the light which does not
receive signal, only output signal, will be the master light),
●LCD display panel, as following:
Operation: Press “MENU” will cycle fourteen different effect.. Press”
UP”, ”DOWN” to select different features. Press ”ENTER” to
confirm.
●Using before please must be check power supply link with
earth wire correctly.
●The specification of the front and rear panel:
Number
Address
LCD display(No.)
1
1
001
2
15 or 36 or 43
015 or 036 or 043
3
29 or 71 or 85
029 or 071 or 085
┇
┇
┇
6

1.Input rated voltage
2.Fuse
3.Power switch button
4.Ground marking
5.DMX IN/ DMX OUT: DMX signal output and input
Technical Specifications
1.Power Supply: AC100~240V 50/60Hz
2.Rated Power: 250W
3.light color: □W2000C(R500mW+G500mW+B1000Mw)*6
□W500C(R200Mw+G100Mw+B200Mw)*6
4.Y axis rotation angle: 0-240°
5.Z axis rotation angle: 0-140°
6.Working Mode: Sound/Automatic/DMX512/Master-Slave
7.Auto mode: 16 kinds of automatic dynamic effect/ 16 kinds of
sound trigger dynamic effect
8.DMX Control Channel: 14CH/35CH/42CH
9.Cool system: forced air cooling system
10.Working temperature: 0℃- 35℃
11.N.W./G.W.: 27kg / 31kg
12.Package size: 101 x 46 x 33cm
7

DMX-512 Channel Introduction
35CH / 42CH mode as following
Channel
Value
Function
CH1
CH1
000-007
Black, motor controllable
008-255
On
CH2
CH2
001-255
Strobe(speed from slow to fast)
CH3
CH3
000-007
Invalid
008-247
Each 14 value be one Y/Z axis macro
effect, total 16 effects (motor
controllable)
248-255
Sound trigger(motor controllable)
CH4
CH4
001-255
Y, Z speed from slow to fast (only valid
for CH3 (008-247))
CH5
CH5
000-014
Invalid
015-255
Color chase( each 20 value be one
color chase effect, total 12 effects)
CH6
CH6
001-255
Color chase speed from slow to fast
(only valid for CH5 (015-255)
CH7
CH7
001-255
Y axis rotation
CH8
CH8
001-255
Y axis fine rotation
CH9
CH9
001-255
Z axis rotation, only when CH9
value=0,6 motors Z axis individual
control valid
CH10
001-255
Z axis fine rotation
8

CH10
CH11
001-255
Y, Z axis rotation speed(only valid
CH7/CH9)
CH11
CH12
001-255
light 1 Z axis rotation
CH13
001-255
light 1 Z axis fine rotation
CH12
CH14
001-255
light 1 Red on/off
CH13
CH15
001-255
light 1 Green on/off
CH14
CH16
001-255
light 1 Blue on/off
CH15
CH17
001-255
light 2 Z axis rotation
CH18
001-255
light 2 Z axis fine rotation
CH16
CH19
001-255
light 2 Red on/off
CH17
CH20
001-255
light 2 Green on/off
CH18
CH21
001-255
light 2 Blue on/off
CH19
CH22
001-255
light 3 Z axis rotation
CH23
001-255
light 3 Z axis fine rotation
CH20
CH24
001-255
light 3 Red on/off
CH21
CH25
001-255
light 3 Green on/off
CH22
CH26
001-255
light 3 Blue on/off
CH23
CH27
001-255
light 4 Z axis rotation
CH28
001-255
light 4 Z axis fine rotation
CH24
CH29
001-255
light 4 Red on/off
CH25
CH30
001-255
light 4 Green on/off
CH26
CH31
001-255
light 4 Blue on/off
CH27
CH32
001-255
light 5 Z axis rotation
CH33
001-255
light 5 Z axis fine rotation
CH28
CH34
001-255
light 5 Red on/off
CH29
CH35
001-255
light 5 Green on/off
9

The difference between 35CH and 42CH in same channel
14CH mode as following
CH30
CH36
001-255
light 5 Blue on/off
CH31
CH37
001-255
light 6 Z axis rotation
CH38
001-255
light 6 Z axis fine rotation
CH32
CH39
001-255
light 6 Red on/off
CH33
CH40
001-255
light 6 Blue on/off
CH34
CH41
001-255
light 6 Green on/off
CH35
CH42
000-128
Invalid
128-255
Motor reset after 5s
Channel
Value
CH35
CH42
CH1
000-007
CH7\CH8\CH9\CH1
0\CH11\CH15\CH19
\CH23\CH27\CH35
valid
CH7\CH8\CH9\CH11\CH12\C
H15\CH16\CH19\CH20\CH22\
CH23\CH27\CH28\CH32\CH3
3\CH37\CH38 valid
008-255
CH2-CH35 valid
CH2-CH42 valid
CH9
001-255
CH9=0, CH11/
CH15/CH19/CH23/
CH27/CH31 valid
CH9=0,
CH11\CH12\CH15\CH16\CH1
9\CH20\CH22\CH23\CH27\C
H28\CH32\CH33\CH37\CH38