Do NOT turn ON the power source, unless the preparation for test running is completed.
!Read this manual carefully before installation work for correct performance.
!Read this manual together with the “Installation & Maintenance Manual” for the indoor unit and
Wireless Remote Control Switch.
Model:
1) This packing contains the following parts. Check the contents and number of the parts.
Operation & Installation Manual for Wireless Receiver Kit
1. Before Installation and Operation
is the blank box for checking. Mark the blank box for the item after checking.!
Clamp
Model Name Q'ty Remarks
1
2
2
2
2
2
Band
Screw
Screw
Screw
Screw
For Fixing Cable
For Fixing Receiver Kit
For Fixing Clamp
For Fixing Receiver Kit
For Fixing Receiver Kit
or Fixing Cable
F
1
SPWRK-V02

2. Installation of Wireless Receiver Kit
2
6) Install the wireless receiver kit onto the wall or ceiling as follows:
(1) Prepare the following box (Field-Supplied).
(2) Insert the cable into the rigid metal conduit.
(3) Fix the fixing bracket of kit by using screw
(Field-Supplied).
(4) Attach the cover same as A-(4).
SPWRK-V02
NOTE:
Install the receiver kit onto the wall or ceiling near the indoor unit.
1) Install the wireless receiver kit and indoor unit at the same time.
2) In case that the wireless receiver kit is installed after installing the
indoor unit, turn OFF the power source of the indoor unit.
3) Check to ensure that the distance between the wireless receiver kit
and the indoor unit is shorter than 5m.
5) Remove the cover by using slotted screwdriver.
Cable
Cable
Screw (Field-Supplied)
This figure shows the case of Switch Box for 1 Controller.
Rigid Metal Conduit
Screw (M4) (Field-Supplied)
Box (Field-Supplied)
(Step 2)
Click Sound.
Check to ensure that
cable is not loosen.
(Step 1)
Hooking Part
Cover
and the EMI Source is larger than 3m.
)
4 Check to ensure that the distance between the wireless receiver kit
Slot
Cover
Holding
Bracket

3
(5)Remove the cover of indoor unit electrical control box and connect the cable to the terminals A and B of
the terminal board (white).
Printed Circuit Board
Terminal Board
(White)
Mark Band "A"
Mark Band "B"
Cable for Wireless Receiver Kit
Example
Electrical Box
for Indoor Unit
After connecting the cable, bind up the remaining cable length portion by band (Factory-Supplied)
and put them in the electrical control box.
NOTES:
Protective box recommend size 3-59/64in.(99.5)by 3-41/64in.
(92.5)by 1-3/8in.(35)mm, fixed hole center is 3 5/64in.(78)mm.
Receiver panel with transparent plastic protective film, the official
may required removed according to user.
Remove the cover by using slotted screwdriver.
When the back cover installation, to tidy up wiring, attention to
the back cover marked \"switch\"
that justify the board of SW1 switch position.
If not according to the requirements of sequenced
operations,may cause install or remove substrate difficulties.

Open the lid of cover so that the following functions are available.
3. Optional Functions
4
2) Optional Setting for Dip Switch (SW3)
1234
Setting of Sub Receiver Kit !!!
Identifying of Indoor Units !!!
: ON, !: OFF
Dip Switch Setting (SW3)
Operation Function
Base
SPWRK-V02
9
Cover Printed
Circuit Board
Hole for
Cable
Switch "COOL"
Switch "HEAT"
EMERGENCY
COOL
HEAT
DEF
TIMER
RUN
FILTER
Dip Switch (SW3)
(Factory Setting)
1)Optional Function Setting

emergency operation
In case that wireless remote control switch is unusable by batteries shortage, etc., perform
1) Proceed the “TEST RUN” mode by using “Operation & Installation Manual” for the wireless remote
control switch.
!Turn OFF all power sources before setting the dip switches.
2) Emergency Operation Setting (Refer to the figure of the item 3 “Optional Functions”.)
(1) Switch “COOL”: Press “COOL” so that the cooling operation is started.
Press “COOL” again so that the cooling operation is stopped.
(2) Switch “HEAT”: Press “HEAT” so that the heating operation is started.
Press “HEAT” again so that the heating operation is stopped.
NOTE:
During the emergency operation, the LED (yellow) blinks (0.5 second ON / 0.5 second OFF).
3) Alarm Code Indication
•In case that some trouble occures because of activation of safety device, etc., “RUN” (red lamp)
blinks (0.5 second ON / 0.5 second OFF).
•Refer to the Installation Manual for outdoor unit about Alarm Code List.
•Alarm Code indicates the blinking times of “DEF” (green lamp) and “FILER” (yellow lamp) as shown
bellow.
“DEF” (green lamp): The blinking is shown at the 2 digit of Alarm Code
“FILTER” (yellow lamp): The blinking is shown at the 1 digit of Alarm Code
(Alphabet Code: A=10 times, B=11 times, C=12 times, .....)
4. Others
as follows.
- Example -
•“Run” (red lamp) blinking (1 second ON / 1 second OFF) indicates abnormal transmitting between
Indoor Units and Outdoor Unit.
"FILTER" (yellow lamp)
Alarm
3 5
"DEF" (green lamp)
"DEF" blinks 3 times (0.5 second ON / 0.5 second OFF)
"FILTER" (yellow lamp) blinks 5 times (0.5 second ON / 0.5 second OFF)