Costan VALZER NEXT Manuale utente

ISTRUZIONI D’USO
PER L’UTENTE
VALZER NEXT
N° DOC. UM000169
REV. “A”
LEGGERE ATTENTAMENTE E CONSERVARE CON CURA
ASSIEME AL MOBILE
INSTRUCTIONS
POURL’UTILISATEUR
LIRE AVEC ATTENTION CE MANUEL ET LE
CONSERVERPRÈS DU MEUBLE AVEC SOIN
USER INSTRUCTIONS
READ CAREFULLY AND KEEP WITH THE CABINET
BETRIEBSANLEITUNGFÜR
BETREIBER
SORGFÄLTING LESEN UND MIT DEM MÖBEL
AUFBEWAHREN
INSTRUCCIONES DE USO PARA
EL USUARIO
LEER ATENTAMENTE Y CONSERVARCON ESMERO
JUNTO AL MUEBLE
INSTRUÇOES PARA O USO
LER COM ATENÇAO E GUARDAR COM CUIDADO JUNTO
AO MÓVEL

AL FINE DI RIDURRE I RISCHI CONNESSI ALL’INFIAMMABILITA’, L’INSTALLAZIONE DI QUESTO APPA-
RECCHIO NON DEVE ESSERE EFFETTUATA SE NON DA PERSONALE ADEGUATAMENTE QUALIFICA-
TO.
OGNI ALTRO USO NON ESPLICITAMENTE INDICATO IN QUESTO MANUALE E’ DA CONSIDERARSI
PERICOLOSO ED IL COSTRUTTORE NON PUO’ ESSERE RITENUTO RESPONSABILE PER EVENTUALI
DANNI DERIVANTI DA USO IMPROPRIO, ERRONEO ED IRRAGIONEVOLE.
SAFETY ADVICE
ENSURE THAT AIR SLOTS ON THE CABINET ENCLOSURE ARE FREE FROM OBSTRUCTION.
DO NOT USE SCRAPE FROST OFF USING TOOLS OTHER THAN THOSE RECOMMENDED BY THE
MANUFACTURER.
DO NOT USE ANY ELECTRICAL APPLIANCES INSIDE THE STORAGE COMPARTMENTS FOR THE
FOOD FROZEN BY THE EQUIPMENT, UNLESS RECOMMENDED BY THE MANUFACTURER.
KEEPING PHARMACEUTICALS, GLASS BOTTLES OR FLASKS IN THE CABINET IS STRICTLY FORBIDDEN
AS THEY COULD GET BROKEN AND ENTAIL A SAFETY HAZARD.
ONLY QUALIFIED PERSONNEL CAN REMOVE PANELS OR GUARDS, AND ESPECIALLY THE ELECTRIC
BOARD COVER, WHEN THIS REQUIRES THE USE OF TOOLS.
DO NOT EXPOSE THE EQUIPMENT TO ATMOSPHERIC AGENTS.
DO NOT USE DIRECT OR INDIRECT WATER JETS ON THE CABINET. DO NOT TOUCH THE EQUIP-
MENT WITH DAMP OR WET HANDS OR FEET; DO NOT USE IT WHILE BAREFOOT.
THE EQUIPMENT IS NOT AIMED TO BE USED BY PERSONS HAVING IMPAIRED PHYSICAL, SENSORIAL
OR MENTAL FACULTIES (CHILDREN INCLUDED), OR BY PERSONS HAVING POOR EXPERIENCE OR
KNOWLEDGE, UNLESS THEY ARE SUPPORTED BY SOMEBODY IN CHARGE OF THEIR SAFETY OR BY
THE INSTRUCTIONS FOR THE USE OF THE EQUIPMENT. SURVEILLANCE MUST BE EXERCISED ON
CHILDREN IN ORDER FOR THEM NOT TO PLAY WITH THE EQUIPMENT.
THE POWER CORDS MUST BE PROPERLY SPREAD OUT, SAFE FROM SHOCKS AND FAR FROM
LIQUIDS, WATER AND HEAT SOURCES, AND IN PERFECT CONDITION. THE USE OF ADAPTOR
PLUGS IS FORBIDDEN.
ENSURE THAT THE POWER SUPPLY VOLTAGE MEETS THE DETAILS ON THE RATING PLATE OF THE
CABINET. THE CABINET MUST BE PROPERLY CONNECTED TO THE EARTHING SYSTEM.
JOBS INVOLVING THE COOLING CYCLE OR THE WIRING SYSTEM MAY ONLY BE PERFORMED BY
QUALIFIED PERSONNEL. DISCONNECT THE CABINET'S PLUG FROM THE MAINS OUTLET BEFORE
ANY JOBS.
DO NOT DAMAGE THE REFRIGERATING CIRCUIT: IT IS FORBIDDENT TO DRILL THE WALLS OF THE
CABINET IN ANY WAY, EITHER INTERNAL OR EXTERNAL (E.G. FOR THE INSTALLATION OF A SUPER-
STRUCTURE, AS THIS COULD BRING DAMAGE TO THE EVAPORATOR AND CONDENSER TUBES
BUILT INTO THE CABINET WALLS.
IF YOU WISH TO STICK ADHESIVE SIGNS ONTO THE CABINET, ONLY USE THIN FOIL. DO NOT LAY
THICK INSULATING LAYERS ON THE EXTERNAL WALLS OF THE EQUIPMENT AS THIS COULS COM-

PROMISE CABINET PERFORMANCE.
IN ORDER TO REDUCE FLAMMABILITY-RELATED RISKS, THIS CABINET MAY ONLY BE INSTALLED BY
SUITABLY QUALIFIED PERSONNEL.
ANY OTHER USE NOT EXPLICITLY MENTIONED IN THIS BOOKLET MUST BE CONSIDERED AS HAZAR-
DOUS. THE MANUFACTURER DISCLAIMS ALL LIABILITY FOR DAMAGE RESULTING FROM IMPROPER,
INCORRECT OR UNREASONABLE USE.
AVERTISSEMENTS DE SÉCURITÉ
MAINTENIR LES OUVERTURES DE VENTILATION BIEN DÉGAGÉES DANS LE BOITIER DE L’APPAREIL.
NE PAS UTILISER DE DISPOSITIFS MÉCANIQUES OU AUTRES MOYENS POUR ACCÉLÉRER LE PRO-
CESSUS DE DÉGIVRAGE DIFFÉRENTS DE CEUX QUI SONT RECOMMANDÉS PAR LE CONSTRUC-
TEUR.
NE PAS UTILISER D’APPAREILS ÉLECTRIQUES A L’INTÉRIEUR DES COMPARTIMENTS POUR LA CON-
SERVATION DES ALIMENTS CONGELÉS PAR L’APPAREIL, SI CEUX-CI NE SONT PAS DU TYPE
RECOMMANDÉ PAR LE CONSTRUCTEUR.
IL EST FORMELLEMENT INTERDIT D’EXPOSER DES PRODUITS PHARMACEUTIQUES ET DES BOU-
TEILLES OU DES EMBALLAGES EN VERRE, CAR ILS POURRAIENT SE CASSER ET DEVENIR DANGE-
REUX.
L’ENLÈVEMENT DE PROTECTIONS OU DE PANNEAUX QUI DEMANDENT L’UTILISATION D’OUTILS
POUR ÊTRE RETIRÉS EST EXCLUSIVEMENT RÉSERVÉ AU PERSONNEL QUALIFIÉ, NOTAMMENT
L’ENLÈVEMENT DE LA COUVERTURE DU CADRE ÉLECTRIQUE.
NE PAS LAISSER L’APPAREIL EXPOSÉ AUX AGENTS ATMOSPHÉRIQUES.
NE JAMAIS UTILISER DE JETS D’EAU DIRECTS OU INDIRECTS SUR LE MEUBLE. NE PAS TOUCHER
L’APPAREIL AVEC LES MAINS OU LES PIEDS MOUILLÉS OU HUMIDES, NE PAS UTILISER L’APPAREIL
LES PIEDS NUS.
L’APPAREIL N’EST PAS DESTINÉ A ÊTRE UTILISÉ PAR DES PERSONNES (ENFANTS COMPRIS) DONT
LES CAPACITÉS PHYSIQUES, SENSORIELLES OU MENTALES SONT RÉDUITES, OU QUI MANQUENT
D’EXPÉRIENCE OU DE CONNAISSANCES À MOINS QU’ELLES PUISSENT BÉNÉFICIER, PAR L’IN-
TERMÉDIAIRE D’UNE PERSONNE RESPONSABLE DE LEUR SÉCURITÉ, D’UNE SURVEILLANCE OU
D’INSTRUCTIONS CONCERNANT L’APPAREIL. LES ENFANTS DOIVENT ÊTRE SURVEILLÉS DE
FAÇON À CE QU’ILS NE JOUENT PAS AVEC L’APPAREIL.
LES CÂBLES D’ALIMENTATION DOIVENT ÊTRE BIEN TENDUS, EN POSITION NON EXPOSÉE À D’É-
VENTUELS HEURTS, NE PAS ÊTRE À PROXIMITÉ DE LIQUIDES OU D’EAU ET DE SOURCES DE CHA-
LEUR ET NE PAS ÊTRE ENDOMMAGÉS. L’UTILISATION DES FICHES D’ADAPTATION EST INTERDITE.
S’ASSURER QUE LA TENSION D’ALIMENTATION CORRESPOND AUX DONNÉES DE PLAQUETTE
DU MEUBLE. IL EST OBLIGATOIRE DE BRANCHER LE MEUBLE A LA TERRE.
LES OPÉRATIONS QUI SONT CONCERNÉES PAR LE CYCLE DE REFROIDISSEMENT OU PAR L’IN-
STALLATION ÉLECTRIQUE DOIVENT ÊTRE EXÉCUTÉES EXCLUSIVEMENT PAR DU PERSONNEL QUA-

-14-
ENGLISH
SAFETY WARNINGS FOR THE APPLIANCES
USING R290 COOLING FLUID (PROPANE)
Propaneisanaturalgas that doesn’taffect the environment
but is inammable.
It is therefore essential to ensure that all refrigerant pipes
are not damaged before connecting the appliance to the mains supply.
Every 8 gr. Of refrigerant, the installation room must have a 1 m³
minimum volume.
The amount of refrigerant of the appliance is indicated on the rating
plate of the device.
In the event of leakage of the refrigerant, avoid using open ames or
sources of ignition in the vicinity of the area of the leak. Be careful not
tonotdamagetherefrigerantcircuitpipesduringpositioning,installation
and cleaning. Avoid using naked ames or sparks inside the appliance.
Warning! Do not damage the refrigerant circuit.
Warning! Do not damage the inner or outer walls of the appliance: the
refrigerant uid circuit may be damaged. In case of damage to the walls,
do not start the appliance and contact a qualied service technician.
Warning! In case of damage to the refrigerant uid circuit, do not start
the appliance and contact a qualied service technician.
Warning! Keep the ventilation openings in the appliance casing or in
the recessed structure clear of obstructions.
Warning! Do not use electrical appliances inside the compartments of
theapplianceforstoringfrozen foodsif thesearenotthoserecommended
by the manufacturer.
Warning! Do not store explosive substences such as aerosol cans with
ammable propellant in this aplliance.
INFORMATION ABOUT USE

-15-
SAFETY INFORMATION
•Read the manual carefully and adhere to the contents before
installing and using the appliance.
•Always keep the instructions manual safe and if the appliance is sold,
hand it over to the new owner.
•This equipment is very dangerous if left exposed to rain, thunderstorms
or bad weather with the power cable plugged into the power socket.
•Do not ever touch or handle the appliance with bare feet or with wet
hands and feet.
•The children must be supervised to ensure that they do not play with
the appliance.
•The packaging materials, such as plastic bags, polystyrene, plastic
cable ties, must not be left in reach of children as they are potential
sources of danger.
•Do not let children play with the appliance e.g. sitting in the baskets
or rocking on or holding the cover, the cooler may overturn, or any
items placed on top of it may fall down.
•After installing the appliance make sure that it is not positioned on
the power cable.
•To disconnect the appliance from the mains, take out the plug. Do not
pull the power cable out of it.
•If the coolant circuit is damaged, it is strictly necessary to turn off the
lights.
•Do not store explosives, such as pressurized containers with ammable
propellant, in this appliance.
•Never connect the cabinet to the power supply if it is damaged ( in
transit or otherwise). When in doubt, contact your service organization
or dealer.
•If the supply cord is damaged, it must be replaces by the manufacturer,
its service agent or similarly qualied persons in order to avoid a hazard.
•Electronic elements may only be replaced by a qualied eletrician or
person with experience in electrical engineering.
•Never use mechanical devices or any other means to accelerate the
defrostingprocess, otherthan thoserecommendedbythemanufacturer.

-16-
HANDLING AND UNPACKING
The unit is shipped anchored onto a wooden base and protected by corner posts, cardboard top and
nylon wrapping. Keep all packaging away from children.
For each subsequent handling of the cabinet, the use of the wooden platform is recommended.
Carefully remove the packaging, taking care not to damage the components and not to throw away
those that will be needed for assembly.
The unit is shipped anchored onto a wooden base
and protected by corner posts, cardboard top and
nylon wrapping.
It must only be handled using a fork lift truck with
adequate power to the load.
Positioning the appliance horizontally or on its side
or upside down is to be strictly avoided.
The equipment MUST be kept vertical.

-17-
SELECTING THE PLACE OF INSTALLATION
In selecting the place of installation, ensure that the following instructions are observed, this being
vital for proper and troublefree working of the cabinet:
• Do not install the cabinet outdoors.
• Do not install the cabinet in the vicinity of heating radiators or other heat sources.
• Do not install the cabint where it is exposed to direct sun light (e.g. through windows).
• Do not install the cabinet where it is exposed to drafts from ventilators open doors.
• Pay attention to air outlet from air conditioners/ ventilators.
• Keep the air intake and outlet area around the plinth area of the cabinet clear of cartons and other
obstacles.
• It is necessary taht the condensing unit obtains a good circulation of air around it; also the area
around the condensing unit should not be obstructed by boxes or other objects; keep a distance
from the wall of 10 cm. at least.
Air-Condion

-18-
INSTALLATION
To move the cabinet around on castor wheels, lift its feet.
Take out packaging and clean all the cabinet using warm water together with 5% of neutral soap then
dry it with a soft cloth; for the glass parts only use specic products, avoiding the use of water which
can leave on the glasses limestone residues.
Keep a distance from the wall of 10 cm. at least.
Cabinet must be installed on a perfectly even surface (please settle the adjustable feet), far away from
any heat source (radiators, stoves, etc) including sun rays.
Good running of the cabinet can be compromised in cases where the airow is disturbed (wind,
ventilators, air conditioning outlets, etc).
Smoothrunningofthe cabinet
is assisted when sufcient air
is permitted to ow through
the bottom of the unit; it is
very important that the grills
atthebasearekeptuncovered.
Do not expose the cabinet
to rain.
Install and position the unit in
such a way so as to allow easy
access to the power socket.
Never use electrical
equipment in the refrigerated
compartment
Never place containers of
liquid on or immediately
above the ticket counter;
should the content spill out,
it would damage the counter.
THE REFRIGERATOR IS NOT SUITABLE FOR WORKING IN DANGEROUS
ENVIRONMENT WITH RISK OF FIRE, EXPLOSIONS OR RADIATIONS.
Operation is regular with ambient temperature
indicated on technical data plate (in the tank).
Insert between glass door and motor space the wood part to
avoid door frame foldings during transport.
Reinsert it when the cabinet is removed.

-19-
Warning!
MAXIMUM ANGLE OF DOOR
OPENING = 115°
For correct working of the torsion bar and to avoid any
break of the door or of the hinge do not exceed the
maximum angle of door opening i.e. 115°.
CLIMATE CLASS ENVIRONMENT OPERATING TEMPERATURE
0 20
1 16
2 22
3 25
4 30
6 27
5 40
7 35
8 23,9
Stop the cabinet by feet.

-20-
For the corect air circulation necessary to leave 4 cm free space between the product and the bottom
of each internal shelf.
LOADING INSTRUCTION
WARNING:
1)Theproductmust notobstructthedisplayareacompletely.
2)Avoid leaving shelves empty so as not to create turbulence
wich may prejudic regular refrige-rated air ow, and cause
needless energy consumption.
4 cm
TOP LOADING LIMIT
INTERNAL SHELF LOADING LIMIT
BOTTOM SHELF LOADING LIMIT
A
A
A
A
4 cm
4 cm
A
INTERNAL SHELF LOADING LIMIT
INTERNAL SHELF LOADING LIMIT
A
4 cm
Altri manuali per VALZER NEXT
1
Indice
Altri manuali Costan Frigorifero

Costan
Costan OPERA GREEN Manuale utente

Costan
Costan EPTAGLOO Istruzioni operative

Costan
Costan GRANVISTA INTEGRAL WL Manuale utente

Costan
Costan GRANVISTA INTEGRAL AIR Manuale utente

Costan
Costan VALZER NEXT Manuale utente

Costan
Costan BLUES 4 Manuale utente

Costan
Costan SOUND TOP ENERGY Manuale utente

Costan
Costan SkyLight Integral NC5 Series Manuale utente

Costan
Costan ARCADE Manuale utente

Costan
Costan MAMBO NEXT Manuale utente