Crown GC-12 Manuale utente

MANUAL 10105R6
INSTALLATION & OPERATION
MANUAL
Gas Fired Steam Jacketed Tilting Kettle
GC-12
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read
the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this
manual for the life of the equipment:
Model #: ___________________________
Serial #: ___________________________
Date Purchased: ____________________
CROWN FOOD SERVICE EQUIPMENT
A Middleby Company
70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9
Telephone: 919-762-1000 www.crownsteamgroup.com
Printed in Canada

INSTALLATION AND OPERATION MANUAL, GAS FIRED TILTING KETTLE, MODEL GC-12
PART NO. 10105R6 22013-07-11
1.0 IMPORTANT NOTES FOR INSTALLATION AND OPERATION
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
WARNING: Improper installation, operation, adjustment, alteration,
service or maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions
thoroughly before installing, operating or servicing this equipment.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable
vapours or liquids in the vicinity of this or any other appliance.
This manual should be retained for future reference.
PURCHASER: Instructions to be followed in te event that the operator of this
appliance smells gas must be posted in a prominent location. This information
shall be obtained by consulting the local gas supplier.
Keep the appliance area free and clear from combustibles.
Do not obstruct the flow of combustion and ventilation air.
Adequate clearances must be maintained for servicing and proper operation.
Intended for commercial use only. Not for household use.

INSTALLATION AND OPERATION MANUAL, GAS FIRED TILTING KETTLE, MODEL GC-12
PART NO. 10105R6 32013-07-11
TABLE OF CONTENTS
DESCRIPTION PAGE
1.0 Important Notes For Installation and Operation ..................................2
2.0 Service Connections ......................................................4
3.0 Introduction .............................................................5
4.0 Installation Instructions ....................................................6
5.0 Operating Instructions ....................................................9
6.0 Cleaning Instructions ..................................................... 11
7.0 Periodic Maintenance ....................................................13
8.0 Service ...............................................................14
9.0 Troubleshooting ........................................................17
Appendix “A”, Material Safety Data Sheet .........................................18

INSTALLATION AND OPERATION MANUAL, GAS FIRED TILTING KETTLE, MODEL GC-12
PART NO. 10105R6 42013-07-11
2.0 SERVICE CONNECTIONS

INSTALLATION AND OPERATION MANUAL, GAS FIRED TILTING KETTLE, MODEL GC-12
PART NO. 10105R6 52013-07-11
3.0 INTRODUCTION
DESCRIPTION
Model GC-12 (12 gallon capacity) gas fired, self-contained, tilting kettle. The kettle has a jacket of
double-wall construction forming a sealed reservoir around the lower two-thirds of the kettle. The
reservoir is charged with distilled water. The kettle is equipped with a “clean lock” to hold kettle in
cooking position or tilted 105 degrees for ease of cleaning. The kettle is also equipped with
automatic ignition, low water cut off and tilt switch, which, when activated, shuts down the burner.
BASIC FUNCTION
The kettle operates by generating steam in the kettle reservoir. The sequence of operation is as
follows:
1. Operator turns the power switch to the on position and sets the temperature control dial to the
desired setting.
2. The red light comes on indicating the kettle is heating. The green “IGNITION” light comes on
indicating that the ignition and burner are active.
3. Once the kettle reaches the set temperature, the red “TEMPERATURE” light and the green
“IGNITION” light extinguish.
4. All kettles are supplied with sufficient water in the jacket. If for any reason the water level falls
below the required amount to operate the kettle, the burner shuts down and the amber light
comes on. See Adding Water in Service section.
5. The sight glass indicates the water level within the kettle jacket.
6. The relief valve is a safety feature which prevents the internal kettle pressure from exceeding
50 PSI. It should never be tampered with.

INSTALLATION AND OPERATION MANUAL, GAS FIRED TILTING KETTLE, MODEL GC-12
PART NO. 10105R6 62013-07-11
4.0 INSTALLATION INSTRUCTIONS
INSTALLATION CODES AND STANDARDS
Installation must conform with local codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA
B149.1, as applicable.
1. The appliance and its individual shut off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at pressures in excess of ½ psi (3.5 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual
manual shut off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
Electrical grounding must be provided in accordance with local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA
C22.2, as applicable.
Ventilation must be provided in accordance with local codes, or in the absence of local codes, with
ANSI/NFPA 96 Standard for Ventilation and Fire Protection of Commercial Cooking Operations.
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is equipped with a three-prong (grounding) plug for
your protection against shock hazard and should be plugged directly
into a properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug. (120V units only).
The electrical wiring diagram is located inside the right hand console of the appliance.

INSTALLATION AND OPERATION MANUAL, GAS FIRED TILTING KETTLE, MODEL GC-12
PART NO. 10105R6 72013-07-11
GAS CONNECTION
WARNING: Do not connect the appliance to the electrical supply until
after the gas connection has been made.
CAUTION: The pipe thread compound used when installing pipes
must be a type that is resistant to the action of liquified petroleum or
propane gases.
1. The Serial and Rating Plate on the unit indicates the type of gas your unit is equipped to burn.
DO NOT connect to any other gas type.
2. A 3/4" NPT line is provided at rear for the connection. The unit is equipped with an internal
pressure regulator which is set at 4" W.C. manifold pressure for Natural Gas and 10" W.C. for
Propane Gas. Use 1/8" pipe tap on the union elbow assembly located in the console for
checking pressure.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of
gas required for satisfactory performance. A steady supply pressure, minimum 6 inch W.C. for
natural gas and minimum 12 inch W.C. for propane gas is recommended. With all units operating
simultaneously, the manifold pressure on all units should not show any appreciable drop.
Fluctuations of more than 25% on natural gas and 10% on propane gas will create problems,
affecting burner operation. Contact you gas company for correct supply line sizes.
Purge the supply line to clean out any dust, dirt or other foreign matter before connecting the line
to the unit. Use pipe joint compound which is suitable for use with L.P. on all threaded
connections.
Test pipe connections thoroughly for gas leaks.
WARNING: Never use an open flame to check for gas leaks. Check all
connections for leaks using soapy water before use.
NOTICE: If this equipment is being installed at over 2,000 feet altitude and was
not so specified on order, contact service department. Failure to install with
proper orifice sizing may void the warranty.

INSTALLATION AND OPERATION MANUAL, GAS FIRED TILTING KETTLE, MODEL GC-12
PART NO. 10105R6 82013-07-11
INSTALLATION
1. Uncrate carefully. Report any hidden freight damage to the freight company immediately.
2. Ideally an exhaust system should be directly above the appliance to exhaust combustion
gases generated by the unit.
3. The appliance is intended for use on noncombustible floors. The minimum clearance from
combustible and noncombustible floor construction is 0" on right side, 0" on left side and 6"
(152 mm) from the back of the flue chimney.
4. Appliance location must allow air supply to unit and obstruction free clearance for air opening
into the combustion chamber.
5. Set the appliance in place and level using spirit level. Level left to right and front to back.
6. Mark hole locations on the floor through the anchoring holes provided in the flanged
adjustable feet.
7. Remove the appliance from installation position and drill holes in locations marked on the
floor. (See installation diagram on Page 4). Insert proper anchoring devices. (Not supplied).
8. Place appliance back in the installation position and Re-level left to right and front to back.
9. Bolt and anchor appliance securely to the floor.
10. Seal bolts and flanged feet with silastic or equivalent compound.
11. Make service connections as indicated.
12. The pressure relief valve is located at the left rear of the unit. This area should be kept clear
and should not be in an area where operators will normally stand. The elbow on the relief
valve should be turned toward the floor. 3/4" diameter pipe may be used to extend to the
floor, but must not be piped directly to a drain. It must be vented to the atmosphere.
13. Check the pressure gauge on the front panel before operating. The reading should be in the
green vacuum zone (below 0 PSI). See “Re-establishing Vacuum” section under Service
Instructions.

INSTALLATION AND OPERATION MANUAL, GAS FIRED TILTING KETTLE, MODEL GC-12
PART NO. 10105R6 92013-07-11
5.0 OPERATING INSTRUCTIONS
FRONT PANEL CONTROLS:
Power Switch
This switch turns the main power to the unit on and off. It must be turned on to heat the kettle. It
should be turned off when the kettle will not be in use for long periods.
Thermostat
Selects the desired internal kettle operating temperature. It also turns on the temperature light
(red) and ignition light (green).
Temperature Pilot Light (Red)
When the kettle has reached set temperature, temperature light (red) will go off.
Ignition Pilot Light (Green)
Comes on with temperature light (red) and indicates ignition has occurred. Should it not come on
with temperature light, this would indicate failed ignition or burnt out light.
Low Water Light (Amber)
All kettles are supplied with sufficient water in the pressurized jacket. If at any time the water level
falls below that required for proper operation, the kettle will not heat and this light will come on.
See “Adding Water” section of service instructions.
Pressure Gauge
The pressure gauge indicates the internal operating pressure of the kettle.
Sight Glass
The sight glass indicates the water level within the kettle jacket.
Pressure Relief Valve
The pressure relief valve is a safety device which prevents the internal kettle pressure from
exceeding 50 psi. It should never be tampered with.

INSTALLATION AND OPERATION MANUAL, GAS FIRED TILTING KETTLE, MODEL GC-12
PART NO. 10105R6 10 2013-07-11
TILTING INSTRUCTIONS
Your kettle has the standard “Clean Lock” feature and may not be tilted without disengaging the tilt
knob located on the console at the top left. This feature locks the kettle in the upright position and
also allows the operator to lock the kettle at 105 degrees for ease of cleaning. Follow these steps
to tilt kettle:
1. Pull out the tilt knob at the top left of console.
2. Using kettle tilt handle, pull kettle forward to desired angle of pour or until kettle locks at 105
degrees. The tilt knob can be released after the kettle has been tilted approximately 10
degrees.
3. Kettle will lock in position at 105 degrees and may be tilted further by pulling the tilt lock knob
a second time allowing the kettle to tilt the full distance.
4. To return the kettle to the upright position, pull out the tilt lock knob and tilt the kettle upward
until it locks in the upright position. The kettle should not move in either direction once in the
upright position.
LIGHTING
1. Ensure the kettle is in the upright position.
2. Open the manual gas shut off valve located at the back of the right-hand console when facing
the front of the unit.
3. Set the thermostat dial in off position. Turn the power switch on.
4. Set the thermostat to desired setting. NOTE: Ignition may not occur at a setting below 2 - 3
on thermostat dial. If ignition light does not stay on, turn off thermostat. Wait five minutes
and repeat the lighting procedure.
WARNING: In the event of main burner ignition failure, a 5 minute
purge period must be observed prior to re-establishing ignition
source.
SHUT DOWN
1. Turn thermostat dial to “OFF” position.
2. Turn power switch to “OFF” position.
3. Close manual gas shut-off valve.
Altri manuali per GC-12
1
Indice
Altri manuali Crown Bollitore

Crown
Crown DL-20F Manuale utente

Crown
Crown GLT-20 Manuale utente

Crown
Crown EL-20F Manuale utente

Crown
Crown DLT-30 Manuale utente

Crown
Crown ELTM-100 Manuale utente

Crown
Crown EC-20T Manuale utente

Crown
Crown GL-40E Manuale utente

Crown
Crown EMT-6-6 Manuale utente

Crown
Crown DK-149 Manuale utente

Crown
Crown DMT-6-6 Manuale utente

Crown
Crown GLT-80 Manuale utente

Crown
Crown GL-20E Manuale utente

Crown
Crown EL Manuale utente

Crown
Crown GL-30 Manuale utente

Crown
Crown DC-6 Manuale utente

Crown
Crown GL-40FE Manuale utente

Crown
Crown Crown EP-30 Manuale utente

Crown
Crown DLT-20TC Manuale utente

Crown
Crown DLT-20F Manuale utente

Crown
Crown EMT-6 Manuale utente