d & b audiotechnik R90 Manuale utente

RR90
Manual 1.6 en

S
y
m
b
o
l
s
o
n
t
h
e
p
r
o
d
u
c
t
P
l
e
a
s
e
r
e
f
e
r
t
o
t
h
e
i
n
f
o
r
m
a
t
i
o
n
i
n
t
h
e
m
a
n
u
a
l
.
W
A
R
N
I
N
G
!
D
a
n
g
e
r
o
u
s
v
o
l
t
a
g
e
!
General information
R90 Manual
Version: 1.6 en, 02/2022, D2403.EN .01
Copyright © 2022 by d&b audiotechnik GmbH & Co. KG; all
rights reserved.
Keep this document with the product or in a safe place
so that it is available for future reference.
We recommend you to regularly check the d&b website for the
latest version of this document.
When reselling this product, hand over this document to the new
owner.
If you supply d&b products, please draw the attention of your
customers to this document. Enclose the relevant documents with
the systems. If you require additional documents for this purpose,
you can order them from d&b.
d&b audiotechnik GmbH & Co. KG
Eugen-Adolff-Str. 134, D-71522 Backnang, Germany
T +49-7191-9669-0, F +49-7191-95 00 00
[email protected], www.dbaudio.com

Contents
1 R90 Touchscreen remote control................................... 4
1.1 Scope of supply.......................................................................... 4
1.2 Intended use................................................................................ 4
1.3 Technical specifications.............................................................. 4
2 R90 Hardware...................................................................... 5
2.1 Power supply............................................................................... 5
2.2 Fitting the power supply cable................................................... 5
2.3 LAN ............................................................................................ 6
2.4 USB.............................................................................................. 6
2.5 Ground connection..................................................................... 6
2.5.1 Earthing measures................................................................... 6
2.6 Connecting cables...................................................................... 6
3 R90 Software......................................................................... 7
3.1 Software Terms of Use............................................................... 7
3.2 Interface...................................................................................... 7
3.3 Settings........................................................................................ 8
3.3.1 Login......................................................................................... 8
3.3.2 System configuration............................................................... 8
3.3.3 Project setup.......................................................................... 10
3.4 System time and date............................................................... 13
3.5 Factory reset............................................................................. 13
4 R90 Web Remote interface........................................... 14
5 R90 Log.................................................................................. 15
Contents
d&b R90 Manual 1.6 en 3

R90 Touchscreen remote control
1.1 Scope of supply
Please verify the shipment for completeness and proper condition
of the items.
Qty. d&b code Description
1 Z6126 R90 Touchscreen remote control [1]
Including:
1 Power supply plug [2] incl. upper/
lower strain relief housing and cable tie.
1 D2403.EN .01 R90 Manual
1.2 Intended use
The R90 Touchscreen remote control is a dedicated solution to
control any d&b audio installation. It is intended as an additional
remote control device to recall presets and scenes and provide
quick access to basic functions, such as global power, mute, level,
and grouping, without using the d&b R1 Remote control software.
Using the OCA/AES70 protocol, it allows easy setup and control
without the need of any additional program code.
Feature set
▪ Up to 15 devices
▪ Recalling up to 9 presets
▪ Global power (on/off)
▪ Master mute
▪ Grouping (Mute, Level)
1.3 Technical specifications
Interfaces
1 x on-board Ethernet adapter 10/100BASE-T with RJ-45 connection
2 x USB 2.0
Protection class
Front side IP54
Rear side IP20
Permissible ambient temperature
Operation 0°C to +55°C
Transport/storage –25°C to +65°C
Permissible relative humidity
up to 95%, no condensation
Power supply
Supply voltage 24 VDC
Power consumption 12 W (max.)
Dimensions and weight
Height x width x depth 150 x 200 x 40 mm (5.9" x 7.87" x 1.57")
Built-in dimensions 141 x 191 mm (5.55" x 7.5")
Weight 0.9 kg/1.98 lb
R90 dimensions in mm [inch]
1 R90 Touchscreen remote control
d&b R90 Manual 1.6 en4

R90 Hardware
The hardware consists of a 7" touchscreen (800 x 480 pixels) IPC
device based on the Beckhoff CP6606 Panel PC. It incorporates a
1 GHz 7AMR Cortex A8 CPU and provides a steel housing with
aluminum front.
Note: For further information on how to install and start up the
device, please refer to the corresponding Beckhoff manual,
which can be downloaded from the download section of the
Beckhoff website at www.beckhoff.com as well as from the
related product page at www.dbaudio.com.
2.1 Power supply
To operate the R90, an exernal 24 VDC power supply capable of
delivering a minimum of 12 W (500 mA) is required. To supply
power to the device, use the power socket [X101].
Pin Signal
1 / 2 n.c.
3
4 GND
5 + 24 VDC
2.2 Fitting the power supply cable
Tools required : Flat-head screwdriver 2 x 0.4 mm.
1. Strip insulation from the cable ends (length of stripped
conductor is 8 - 9 mm).
2. Plug in the cable ends to the 5-pole plug connector in
accordance with the wiring table above.
3. Thread the cable tie into the lower part of the strain relief
housing.
4. Place the plug connector into the lower part of the strain relief
housing. Tighten the cable tie and cut off the remaining plastic
strap.
5. Fix the upper part of the strain relief housing by snapping it
onto the lower part.
Fit the power supply cable
2 R90 Hardware
d&b R90 Manual 1.6 en 5

R90 Hardware
2.3 LAN
To connect the device to the d&b Remote network, use the LAN1
RJ45 connector socket ([X102] - 10/100BASE-T Local Area
Network), as shown in the graphic opposite.
2.4 USB
Two USB 2.0 ports are provided ([X104]/[X105]) to allow
either firmware updates via a USB stick (see also Þ R90 Software
- Settings - System config Þ Firmware update on page 8) or to
connect an external USB keyboard for data entry (see also Þ R90
Web Remote interface Þ Keyboard entries on page 14).
Note: Before installing the device into a wall, we recommend
you to use appropriate USB extension cables to ensure better
accessibility of the USB ports.
2.5 Ground connection
The device is grounded via the [M4 Ground] connection.
2.5.1 Earthing measures
Earthing connections bleed off interferences from external power
supply cables, signal cables, or cables to peripheral equipment.
Establish a low-resistance connection from the earthing point of the
device housing (Þ Ground connection) to the central earthing
point onsite (e.g. the equipment cabinet, in which the device is
installed).
2.6 Connecting cables
When connecting cables to the device, please observe the
following order:
1. Disconnect all devices involved from their power supplies.
2. Connect all cables to the R90 and to the devices to be
connected.
3. Ensure that all screw connections between connectors and
sockets are tight.
4. Reconnect all devices to their power supplies.
d&b R90 Manual 1.6 en6

R90 Software
3.1 Software Terms of Use
The software installed on the R90 shall only be used to the extent
intended/documented. d&b shall not be liable for any damage
resulting from any other or non-conforming use.
You may not decompile, copy, alter, or enhance the software
installed on the R90 or its source code in any form. d&b will
investigate any infringement of copyright or intellectual property
rights.
3.2 Interface
The display interface of the R90 can be used in two different ways:
▪ manually using the 7" touchscreen
▪ via web remote control
For more information about the web remote control, please refer
to Þ Chapter 4 "R90 Web Remote interface" on page 14.
Quick tab
[1] Power
Main power switch.
[2] Mute
Master mute function.
[3] AmpPresets
Recall presets from the devices.
Menu bar
[4] Time and date
[5] Preset switch
Three presets out of a maximum of nine presets can be
displayed at once. The preset switch is activated as soon as
a project includes more than three presets. In this case, all
presets are displayed successively in the «Quick tab» bar in
groups of a maximum of three.
[6] Log
System and devices log messages.
[7] Group control
Fader and mute controls.
[8] Info
Copyright and current software version.
[9] Settings
Project setup and system configuration.
3 R90 Software
d&b R90 Manual 1.6 en 7

R90 Software
3.3 Settings
3.3.1 Login
Once the device has booted, selecting «Settings» on the bottom
right of the touchscreen opens the R90 login screen.
By factory default, the login data is:
User name: Admin
Password: Admin
Select and hold the «View» button to show the
entered password for verification.
If you are inactive for more than 15 minutes, you will be logged
out automatically. A new login is required.
To change your system configuration, navigate to "«Settings»
Þ «System config»".
To change your project settings, navigate to "«Settings»
Þ «Project setup»".
3.3.2 System configuration
Network settings
Navigate to Settings Þ System config Þ Network settings.
You can set your IP address manually («Static») or obtain it
automatically via DHCP.
To set your IP address manually, please proceed as follows:
1. Check the «Static» option.
2. Enter your IP address and subnet mask.
3. Select «Apply»
↳The device restarts automatically.
Firmware update
A new firmware can be loaded and installed via the USB ports of
the device. The folder with the new unzipped firmware package
must be stored in the root directory of the USB drive.
To update your firmware, please proceed as follows:
1. Download the latest firmware from www.dbaudio.com.
2. Extract the *.zip file into the root directory of your USB stick.
3. Insert your USB drive to one of the USB ports of the device
([X104] or [X105]).
4. Navigate to Settings Þ System config Þ Firmware update.
5. Select «Copy firmware package».
↳The system will reboot automatically and install the new
firmware.
6. Remove the USB drive.
Set static IP address
d&b R90 Manual 1.6 en8

R90 Software
Change password
Navigate to «Settings» Þ «System config» Þ «Password».
To change your password, please proceed as follows:
1. Enter your user name.
2. Enter the new password.
↳Select and hold the «View» button to show the entered
password for verification.
3. Confirm your new password.
4. Select «Save» to apply your new password.
Lock screen and energy-saving mode
Navigate to «Settings» Þ «System config» Þ «Lock screen»
To protect the application from unauthorized access or to prevent
accidental modifications, two different locking options are
available:
▪ Manual locking
▪ Auto-locking
Once the screen is locked, either manually or automatically, all
controls on the user interface become read-only after a specified
number of minutes.
Manual locking
To activate the manual locking, proceed as follows:
1. Make a tick on the «Screen locking» option.
↳The manual locking option is now activated.
2. Navigate to the home screen.
3. Select the «Screen unlocked» button.
↳The screen is now locked, no touchscreen input is possible.
The icon on the button changes from an unlocked to a
locked padlock.
4. To unlock the screen, select the «Screen locked» button.
↳The button icon changes to an unlocked padlock.
Auto-locking
To activate auto-locking, proceed as follows:
1. Make a tick on the «Screen locking» and
«Automatically lock screen» options.
↳The «Automatically lock screen» option is
now activated.
2. Set the time after which the screen should become inactive.
3. Optional: Make a tick on the «PIN» option and enter your
PIN (one to eight numbers).
↳If the PIN input field is left empty, the PIN function is
disabled.
To see the PIN in plain text, select and hold the «View»
button.
Change password
Screen locking settings "Manual locking"
Screen locking settings "Auto-locking"
d&b R90 Manual 1.6 en 9

R90 Software
4. To unlock the screen, select the «Screen locked» button.
↳If no PIN is set, the button icon changes to an unlocked
padlock and the screen is unlocked. Otherwise the number
pad appears for entering the PIN.
Screen energy saving
To activate the energy-saving mode, proceed as follows:
1. Select the «Screen energy saving» option.
↳The «Screen energy saving» option is now activated.
2. Set the time after which the screen is switched off.
3. To deactivate the screen energy saving mode, touch anywhere
on the screen. The screen turns back on.
Bypass lock screen (admin)
To bypass the lock screen, proceed as follows:
1. On the home screen, select the «Screen locked» button.
↳The number pad is shown.
2. Select the «Admin» button.
↳The normal login screen is shown.
3. Enter your user name and password.
4. Select «Enter».
↳If the login is successful, the screen is unlocked
automatically.
3.3.3 Project setup
Device
On the «Device» tab, you can set up devices and assign the IP
address to each device.
To add a device and set its IP address, please proceed as follows:
1. Select an empty field within the «IP Address» column.
2. Enter the corresponding IP address.
3. Repeat Step 1 & 2 for all devices to be added.
4. Select «Read device data» to detect the device type(s)
automatically.
Settings Screen energy saving
Bypass locks creen
Device setup
d&b R90 Manual 1.6 en10
Altri manuali per R90
2
Indice

















