d2itsu APD-9CK Manuale utente

Local air conditioner
Model: APD-9CK
Thank you for choosing our product.
For proper operation, please read and keep this manual carefully.
If you have lost the Owner’s Manual, please contact the local agent or visit
sat.eurofredgroup.com.
USER'S MANUAL

Content
This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from un-
controlled waste disposal, recycle it responsibly to promote the sustainable reuse of mate-
rial resources. To return your used device, please use the return and collection systems or
contact the retailer where the product was purchased. They can take this product for envi-
ronmental safe recycling.
R32: 675
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Operation Notices
The Refrigerant .........................................................................................................1
Operation Environment ............................................................................................2
Safety Warning .........................................................................................................
Part's Name ..............................................................................................................4
Operation Guide
Operation Introduction for Control Panel .................................................................5
Buttons on Remote Controller .................................................................................7
Introduction for Icons on Display Screen .................................................................7
Introduction for Buttons on Remote Controller .........................................................8
Function Introduction for Combination Buttons ......................................................10
Operation Guide .................................................................................................... 11
Replacement of Batteries in Remote Controller .....................................................1 1
Maintenance
Clean and Maintenance..........................................................................................12
Malfunction
Malfunction Analysis ..............................................................................................14
Installation Notice
Installation Precaution ...........................................................................................17
Preparation before Installation ...............................................................................18
Installation
Removing Collected Water ....................................................................................20
Install Wire Hook ...................................................................................................19
Operation Test .......................................................................................................34
Installation in a double-hung sash window ............................................................23
Installation in a sliding sash window ......................................................................26
Installation and Disassembly of Heat Discharge Pipe............................................31
Attached Sheet
Electric Schematic Diagram...................................................................................34

Explanation of Symbols
Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
Indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury.
Indicates important but not hazard-related information,
used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word
WARNING or CAUTION.
WARNING
CAUTION
DANGER
N OTIC E

1
The Refrigerant
WARNING
To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The used refrigerant is the fluoride R32, which is specially cleaned.
The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion
under certain conditions. But the flammability of the refrigerant is very low. It can
be ignited only by fire.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R32
has got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture. Should repair be necessary, contact your nea-
rest authorized Service Centre. Any repairs carried out by unqualified personnel
may be dangerous. The appliance shall be stored in a room without continuously
operating ignition sources. (for example: open flames, an operating gas appliance
or an operating electric heater.) Do not pierce or burn.
Appliance shall be installed, operated and stored in a room with a floor area larger
than 4m .
Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s
instructions only. Be aware that refrigrants not contain odour. Read specialist’s
manual.
2
Appliance filled with flammable gas R32.
Before install and use the appliance, read the owner’s manual first.
Before repair the appliance, read the service manual first.

2
Operation Environment
● This air conditioner can only be used for family, not for
commercial industry.
● The appliance is for indoor use only.
● The air conditioner must be operated within the temperature range:
16°C ~ 35°C.
● The appliance must be positioned so that the plug is accessible.
● Reserved space around the air conditioner should be 12″(30cm)
at least.
● Do not operate the air conditioner at humid environment.
● During operation, close doors and windows to improve cooling effect.
● Please keep air inlet and air outlet clean, no obstacles.
to avoid noise and vibration.
● Please put the air conditioner at smooth and flat ground for operation
● This air conditioner is equipped with castors. Castors should slide
at smooth and flat ground.
● Prohibit inclining or turning over the air conditioner. If there’s abnor-
mity,please disconnect power immediately and contact dealer.
● Avoid direct sunshine.
30cm 30cm
30cm

3
Safety Warning
● Before operation, please confirm whether power specification
● Before cleaning or maintaining the air conditioner, please turn off
air conditioner and pull out the power plug.
in order to avoid a hazard.
manufacturer or professional person.
complies with that on nameplate.
● Please use the grounded power. Make sure the gounding is reliable.
● If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person
● Do not insert or pull out the power plug with wet hands.
disconnect power at once and then contact local dealer.
● If abnormal condition occurs (e.g. burned smell), please
● If the power cord is damaged, it must be replaced by
● When nobody is taking care of the unit, please turn it off and
remove the power plug or disconnect power.
● Do not splash or pour water on air conditioner. Otherwise, it may
cause short circuit or damage to air conditioner.
portable room air conditioner without supervision.
●
If drainage hose is used, ambient temperature can't be lower than
0℃.Otherwise, it will cause water leakage to air conditioner.
● Prohibit inserting any objects into the air conditioner.
● Do not use an extension cord.
● Do not repair or disassemble the air conditioner by yourself.
● Do not put or hang dripping objects above the air conditioner.
● Keep children from playing or climbing on the air conditioner.
● Children and disabled people are not allowed to use the
● Far away from fire source, inflammable and explosive objects.
● Prohibit operating heating equipment around the air conditioner.
● Make sure the power cord hasn’t been pressed by hard objects.
● Do not pull or drag the power cord to pull out the power plug or
move the air conditioner.
● This appliance can be used by children aged from 8 years and
● Children shall not play with the appliance.
● Cleaning and user maintenance shall not be made by children
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
without supervision.

4
1Controller panel
2
Swing louver
3
Guide louver
4Castor
Wire-fixing hook
5
Plug of power cord
7Gastor
8Air inlet
9Joint A
10 Heat discharge pipe
11 Joint B+C
6
Part's Name
11 10 9
6
7
8
Heat discharge pipe and other installation accessories can't be discarded.
NOTICE:
1
2
3
4
Remote controller
5

5
Name of control panel
ON/OFF button
Mode button
+ / - button
Fan speed indicator
Dual-8 nixie tube
Fan mode indicator
Cool mode indicator
Dry mode indicator
Sleep button
Fan button
Timer button
Operation of control panel
Note:
●After putting through the power, the air conditioner will give out a sound. After
that, you can operate the air conditioner by the control panel.
●Under ON status, after each pressing of the button on control panel, the air
conditioner will give out a sound. Meanwhile, corresponding indicator on control
panel will be bright.
●Under OFF status, dual-8 nixie tube on control panel won’t display.
Under ON status, dual-8 nixie tube on control panel will display set temperature
under cooling mode, while it won’t display under other modes.
Pressing this button can turn on or turn off the air conditioner.
Under cooling mode, press “+” or “-” button to increase or decrease set temperature by
1°C(°F). Set temperature range is 16°C(61°F)~30°C(86°F). Under auto, drying
or fan mode, this button is invalid.
ON/OFF button
+ / - button
1
2
Operation Introduction for Control Panel

6
Press this button and the mode will circulate according to below sequence:
COOL→DRY→FAN
COOL: Under this mode, cooling mode indicator is bright. Dual-8 nixie tube displays
set temperature. Temperature setting range is 16
°C
~30
°C
.
DRY: Under this mode, drying mode indicator is bright. Dual-8 nixie tube won’t
display.
FAN: Under this mode, the air conditioner only blow fan. Fan indicator is bright.
Dual-8 nixie tube won’t display.
Mode button
3
Press this button and the fan speed will circulate as “low speed→ medium speed →
high speed→ auto fan→ low speed”.
Fan button
4
Timer
5
Press timer button to enter into timer setting mode. Under this mode, press " "
or " " button to adjust the timer setting. Timer setting will increase or decrease
0.5 hour by pressing " " or " " button within 10 hours, while timer setting will
increase or decrease 1 hour by pressing " " or " " button beyond 10 hours.
After timer setting is finished, the unit will display temperature if there’s no
operation for 5s. If timer function is started up, the upper indicator will keep the
display status. Others, it won’t be displayed. Under timer mode, press timer button
again to cancel timer mode.
+
+
+
-
-
-
Sleep
6
Press sleep button to enter into sleep mode. If the controller operates at cooling
mode, after sleep mode is started up, preset temperature will increase by 1°C
within 1 hour ;preset temperature will increase by 2°C within 2 hours and then the
unit will operate at this temperature all the time; Sleep function is not available for
fan mode, drying mode. If sleep function is started up, the upper indicator will keep
the display status. Others, it won’t be displayed.
Operation Introduction for Control Panel

7
Buttons on Remote Controller
Introduction for Icons on Display Screen
21
3
4 5
6 7
1
3
5
2
4
6
7
ON/OFF button
MODE button
+/- button
FAN button
X-FAN button
SLEEP button
TIMER button
Timer on Timer off Sending signal
X-fan operation
Sleep operation
Lock
Set speed
Set timeSet temperature
Fan operation
Dry operation
Cool operation X-
Indice
Lingue:
Altri manuali d2itsu Condizionatore d'aria





















