Danfoss RZ1 Manuale utente

Z-Wave Electronic
Radio-Frequency Receivers
(1-Channel)
RZ1 and RZ1-HP
Installation Guide
Danfoss Heating
MAKING MODERN LIVING POSSIBLE

RZ1 AND RZ1HP
2
For a large print version of these instructions
please call Marketing on 0845 121 7400.
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other
printed material. All trademarks in this material are property of the respective companies.
Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss Heating 3
GB
Index
1.0 Specication ...............................................................................................4
2.0 Mounting Instructions ............................................................................5
2.1 Wiring............................................................................................................6
3.0 Understanding your RZ1........................................................................ 7
4.0 Connecting devices to the RZ1............................................................8
4.1 Disconnecting devices from the RZ1.................................................9
4.2 Include devices to network, not using RZ1 relay output............ 9
4.3 Exclude devices from network, not using RZ1 relay output....10
4.4 Including the RZ1 as a secondary controller to a network ......10
4.5 Excluding the RZ1 as a secondary controller to a network......11
5.0 Implementing a network controller shift.......................................12
5.1 Initiating a primary controller shift in an undened
network using the RZ1..........................................................................12
5.2 Initiating a primary controller shift with the RZ1 being
promoted to the primary role ............................................................13
6.0 Using the protection capabilities......................................................13
7.
0 Factory Reset ............................................................................................14
8.0 Z-Wave supported and controlled classes.....................................14
9.0 Glossary ......................................................................................................15
RZ1 and RZ1-HP
Z-Wave Electronic Radio Frequency Receiver
(1 Channel)

RZ1 AND RZ1HP
4
GB
Radio Controlled Room Thermostat Receiver Module
RZ1 RZ1-HP
Supply Voltage 230 Vac ± 15%, 50Hz
Construction EN 60730-1, EN 300-220-1
Maximum Ambient
Temperature 45°C
Switch Type 1 x SPDT, type 1B
Switch Rating 230 Vac, 3 (1) A
(Total current)
230 Vac, 12 (6) A
(Total current)
IP Rating IP 40
Control Pollution Situation Degree 2
Max. Range 30 metres
Operating Frequency 868.42 MHz
Software Classication Class A
Rated Impulse Voltage 2.5kV
Ball Pressure Test 75°C
1.0 Specication

Danfoss Heating 5
GB
2.0 Mounting Instructions

RZ1 AND RZ1HP
6
GB
1 2 34
ELECTRONICS
N L
COM ZONE
1 ON
ZONE
1 OFF
Note: For mains voltage applications link terminals L and 2.
2.1 Wiring RZ1

Danfoss Heating 7
GB
3.0 Understanding your RZ1
The RZ1 receiver unit uses a combination of coloured LEDs to indicate
the current operating mode/output status. For the purpose of this
document the indicator lights will be split into two distinct groups;
CHANNEL LEDs and PROGRAMME LED. More information is listed
below together with explanations of each of the LED colour states.
Programme
LED
Channel LED
Programme LED
O Awaiting Bind/Unbind button press request
Green Normal Run Mode
Green (slow ash) Factory Reset State
Red Programme Mode
Red (slow ash) Binding/association in progress
Orange Primary controller shift mode enabled
Orange (fast ash) Failed to bind
Channel LED(s) - Programme Mode
O Channel Bound/Associated
Red Channel not Bound/Associated
Red (slow ash) Channel in process of being
bound/associated
Channel LED(s) - Run Mode
O Output OFF
Green Output ON
Red Channel not Bound
Red (fast ash) Channel Bound but no communication
Red (slow ash) Channel manually overridden to an OFF state
Green/Orange
(slow ash)
Channel manually overridden to an ON state

RZ1 AND RZ1HP
8
GB
4.0 Connecting devices to the RZ1
To establish a connection with another Z-Wave enabled unit (i.e. RET
BZ), the RZ1 must be placed into its PROGRAMME MODE.
Once the RZ1 is in PROGRAMME MODE, each channel will present
whether it has an existing binding in the following way:
Channel LED RED = unbound/no device present.
Channel LED OFF = Channel successfully bound/ device located and
communication established.
To establish communication and bind a device to the RZ1:
1. Press and release PROG button. The PROG LED will light up
RED.
2. Channels with no devices bound will show RED LED as well.
3. Press the button for the channel you wish to bind, the LED will
ash RED slowly.
4. Press the ‘include initiator’ button on the wireless device to be
connected to the RZ1 (On some devices you may need to press
and hold the include initiator button for up to 10 seconds).
5. Once binding has nished the LED for the channel just bound
will go out indicating success. If there was an error in the binding
process the PROG LED will ash ORANGE rapidly. If this occurs
acknowledge the error by pressing the PROG button and return
to step 1 to begin the process again.
6. Press PROG to return to normal operating mode (PROG LED
shows GREEN).

Danfoss Heating 9
GB
Occasionally you may need to remove a thermostat or other Z-Wave
device from the RZ1 receiver. To do this, follow the procedure below:
1. Press PROG to set the RZ1 into PROGRAMME mode.
2. Press the button for the associated channel to be un-bound/
disconnected (RED channel LED will ash).
3. Press the ‘exclude initiator’ button on the device to be removed
(On some devices you may need to press and hold the include
initiator button for up to 10 seconds).
4. When the device has been removed, the RED LED for that
channel will illuminate continuously.
5. Press PROG to return to normal operating mode.
4.1 Disconnecting devices from the RZ1
4.2 Include devices to the network,
not using the RZ1 relay output
If you wish to include a device to the network but not use the relay
function of the RZ1, follow this procedure:
1. Press the PROG button the PROG LED should turn RED.
2. Press the PROG button for at least 3 seconds or until the PROG
LED goes out.
3. Press and release within 3 seconds the PROG button, the PROG
LED should ash RED slowly indicating that an inclusion has
started.
4. Begin the inclusion process on your remote device.
5. If the process is successful the PROG LED will show solid RED.
Press PROG to return to normal operating mode.
6. If unsuccessful the PROG LED will ash ORANGE quickly. Press
the PROG button to return to step 1 and try again.
7. Once the inclusion is successfully completed, press the PROG
button to return to normal operating mode.

RZ1 AND RZ1HP
10
GB
If you wish to exclude a device from the network that does not use
the relay function of the RZ1, follow this procedure:
1. Press the PROG button, the PROG LED should turn RED.
2. Press the PROG button for at least 3 seconds or until the PROG
LED goes out.
3. Press the PROG button until the PROG LED ashes RED slowly
indication that exclusion has started.
4. Begin the exclusion process on your remote device.
5. If the process is successful the PROG LED will show solid RED.
Press PROG to return to normal operating mode.
6. If unsuccessful the PROG LED will ash ORANGE quickly. Press
the PROG button to return to step 1 and try again.
7. Once the exclusion is successfully completed, press the PROG
button to return to normal operating mode (PROG LED
GREEN).
4.3 Exclude devices not using the RZ1 relay
output from the network
If you already have a primary controller in the network and wish to
add the RZ1 as a secondary controller, follow the steps below: -
1. Place the RZ1 into programme mode by pressing the PROG
button (Programme LED will turn RED)
2. Activate the include/bind initiator on the primary controller in
the network.
3. Press and hold the programme and channel buttons until the
RED LED ashes slowly indicating that inclusion as a secondary
controller has been started.
4. The RZ1 will attempt to connect to the network.
5. Once the RZ1 has successfully been incorporated into the
network, the programme LED will return to its continuously on
RED state.
4.4 Including the RZ1 as a secondary controller
to a network
Altri manuali per RZ1
1
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Danfoss Ricevitore

Danfoss
Danfoss MCF 106 Manuale utente

Danfoss
Danfoss SonoRead 868 Manuale utente

Danfoss
Danfoss SonoRead 868 Manuale utente

Danfoss
Danfoss MP20 Series Manuale utente

Danfoss
Danfoss MP20 Series Manuale utente

Danfoss
Danfoss RX1-S V2 Manuale utente

Danfoss
Danfoss SonoCollect 210 Manuale utente

Danfoss
Danfoss SonoCollect 210 Manuale utente

Danfoss
Danfoss RX1 Manuale utente

Danfoss
Danfoss RZ1 Manuale utente