Dantherm DRC1 Manuale utente

Wireless Remote Controller DRC1 for
CDP/CDP-T/CDF 40-50-70
INSTRUCTION
en • de • fr • it • es • pt • da • ru • pl • nl Rev. 1.1 • 2019-W37-4


3
Languages
Wireless Remote Controller DRC1 (en) ....................................................4
Kabellose Fernbedienung DRC1 (de).....................................................13
Commande à distance sans l DRC1 (fr). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Comando a distanza senza li DRC1 (it) ..................................................31
Controlador remoto inalámbrico DRC1 (es) ..............................................40
Controlador remoto sem os DRC1 (pt) ..................................................49
Trådløs ernbetjening DRC1 (da) ........................................................58
Беспроводная панель дистанционного управления DRC1 (ru) .........................67
Bezprzewodowy pilot sterowania DRC1 (pl). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Draadloze afstandsbediening DRC1 (nl). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
en
de
fr
it
es
ru
pl
nl
pt
da

4
EN
Wireless Remote Controller DRC1 (en)
Table of contents
Overview ................................................................................5
Mating ..................................................................................6
General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
User menu - Set points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installer menu ...........................................................................9
Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

5
EN
Warning It is the responsibility of the operator to read and understand this service manual and other
information provided and to use the correct operating procedure.
Read the entire manual before using the control panel. It is important to know the correct
operating procedures for the unit and all safety precautions to prevent the possibility of
property damage and/or personal injury.
Product description The DRC1 is a wireless remote control panel for use with Dantherm dehumidier range
CDP/CDP-T /CDF 40-50-70.
In this manual you will learn how to use the DRC1 remote control panel to control your
dehumidier.
The range of DRC1 is up to 50 meters depending on conditions.
Remote panel Layout Humidity scale
Humidity display
Dehumidifying Heating Remote Lock
Radio symbol
Battery indicator
Temperature scaleTemperature display
extractor Fan ServiceInformationFail Symbol
Up
Down
Left Right
Enter
Humidity and Temperature scale.
Temperature scale from 0° till 40°C.
Humidity scale from 0 to 99 % RH
Antennae
USB cable The USB cable is for updating software.
It can also be used as external power supply.
Overview

6
EN
Mating Mode Before use, the DRC1 must be mated with the CDP unit.
This section describes how to mate the DRC1 with the dehumidier.
Mating
Procedure 1. Insert batteries > Display ashes (if it does not ash, press the left button for 10 seconds and wait
until the display starts to ash)
The DRC1 will search for the dehumidier for 2 minutes, during which time mating can be done:
- Press the up and down buttons on the DRC1 at the same time for 5 seconds
Note: this must be done while the DRC1 is searching for the dehumidier.
If this procedure does not work:
Switch o the dehumidier and wait for 5 seconds and then switch it on again.
2. The dehumidier will send a serial number to the DRC1.
When mating is successful, the radio icon comes on.
3. The dehumidier will conrm connection by showing code“Conn” for 3 sec-
onds
More than one remote control panel can be connected to the dehumidier.
Navigation ENTER press and hold for 3 seconds to enter user menu setup
UP and DOWN buttons to navigate between icons.
LEFT and RIGHT buttons allows to change set points value 1press = 1unit
ENTER conrms new set point value and automatically switches to next icon/or exits the
menu
Press and hold RIGHT for 5 seconds to enter installer menu setup. ( Exit setup menu rst)
When no button is pressed for 10 sec, the DRC1 exits the menu and returns to readings
screen
Failed mating If mating fails and is shown in the display and the radio symbol ashes
Reset DRC1 and repeat mating process.
Standard readings Standard readings when connected:
-Stand by, RH and ºC scale
-Compressor active, dehumidifying symbol on
End
point
End
point
Mating
Press and hold for 10 seconds to reset
the serial number stored in DRC1.

7
EN
Operation
When the dehumidier is running the dehumidifying symbol ( ) is shown in the DRC1
display.
When heating is toggled ON, the heating icon ( )will be shown in the DRC1 display.
When the extractor fan is turned on, the extractor fan icon ( ) will be shown in the DRC1
display.
Fail Condition
If the dehumidier enters fail mode, the warning sign ( ) will be shown in the DRC1 display.
Locked remote
The DRC1 is equipped with switch in the battery compartment.
When switched to ”lock” position, the buttons on the DRC1 become inactive.
The display will still update with information, but does not allow user inputs.
Press and hold for 10
seconds to reset the serial
number stored in DRC1.
Press and hold for 5
seconds to enter
installer menu.
Press and Hold for 3
seconds to enter
user menu setup.
General information

8
EN
Dehumidifying set point
The humidity value and the dehumidifying icon will ash.
The display shows the desired humidity set point.
While ashing, the value can be increased or decreased by pressing Up/Increase or
Down/Decrease button on DRC1.
Press enter to conrm humidity set point and go to next menu page.
Temperature set point
The temperature value and the heating icon will ash.
The value displayed shows the desired temperature set point. While ashing, the value can
be increased or decreased by pressing Up/Increase or Down/Decrease button on the DRC1
Maximum: 34 °C, Minimum: 5 °C. Press enter to conrm new set point and go to next menu
page.
User menu - Set points
Decrease with 1 unit
Increase with 1 unit
Navigation between icons
Navigation between icons
Press for 3 sec to enter
user menu setup.
Press to conrm.
Decrease with 1 unit
Increase with 1 unit
Navigation between icons
Navigation between icons
Press for 3 sec to enter
user menu setup.
Press to conrm.

9
EN
Fan set point.
When the extractor fan icon ashes at 0.5 Hz and extractor fan set point value is shown on info
line.
Left or right button to decrease or inrease value. Enter to conrm set point and go to next
icon.
If you do not conrm change, the new setpoint will not be stored
Service interval
While ashing, the service interval can be increased by pressing RIGHT Button or decreased
by pressing the LEFT Button.
Maximum 99 Weeks. Minimum is 1 week.
Decrease with 1 unit
Increase with 1 unit
Navigation between icons
Navigation between icons
Press to conrm.
Decrease with 1 unit
Increase with 1 unit
Navigation between icons
Navigation between icons
Press to conrm.
Installer menu Press and hold for 5 seconds to enter installer menu.

10
EN
Alarms
Ambient condition
Stand-by mode 2
DRC1 enters stand-by mode 2 when ambient conditions are out of operation range.
The display will show temperature and Rh readings when the unit is in stand-by mode 1.
This state will only get corrected when the ambient temperature (abt) or ambient humidity (abrh)
is in range, and can not be dismissed.
You can enter menu setup to modify set point values – only in this case.
While in Menu Setup, the alarm icon turn o and set point value will be shown instead of
“Abt/Abrh”code on INFO line
Sensor fail
Dehumidier is stopped because sensor failure is detected.
Sensor Fail can not be dismissed from DRC1.
Use UP or DOWN button to see which sensor/sensors are defect
If all sensors are defect these codes show in the following sequence:“COnd” “EVAP”
“RH/T”
It is not possible to enter menu setup to modify set point values
Condensor sensor fail
If condenser sensor is defected, then“COnd”code will be shown when pressing UP or DOWN
when screen shows Sensor fail code“SEnS”.
If no buttons pressed within 10 seconds then screen will again show “SEnS”again.
It is not possible to enter menu setup to modify set point.
Press for 3 seconds to enter
user menu setup.
Press for 5 seconds
to enter installer
menu setup
Press to see which sensor
is defect.
Press to see which sensor
is defect.