4
Initialization
The initialization interface to the RFID module is auto baud detectable by the printer. Commands
necessary to enable, configure, read, write, and verify RFID tags are detailed below, arranged in the
following sections: Database / Menu, Data Input, Interfaces, Option Feedback, and Diagnostics.
Database / Menu
Menu mode accesses the following system level data (below, menu selections are listed on the left and
available parameters are listed on the right; see the Operator’s Manual for details):
PRINTER OPTIONS
RFID
MODE DISABLED, HF (Securakey), UHF CLASS 1 (Alien),
UHF MULTI-PROTOCOL (Samsys)
POSITION 0.00 - 4.00 (If 0.00 then the Print Position is used to
encode tag; otherwise, the Presented Position is used.)
HF SETTINGS
TAG TYPE ISO 15693, TI, PHILIPS, ST LRI512, ST LRI64
AFI VALUE 2 Character Hex Value (Industry Codes)
AFI LOCK ENABLED or DISABLED
DFSID VALUE 2 Character Hex Value (Industry Codes)
DFSID LOCK ENABLED or DISABLED
EAS VALUE 2 Character Hex Value (Mfg. Codes)
AUDIO INDICATOR BUZZER ON or BUZZER OFF
ERASE ON FAULT ENABLED or DISABLED
UHF SETTINGS
TAG TYPE EPC 0, EPC 0+ MATRICS, EPC 0+ IMPINJ, EPC 1,
UCODE EPC 1.19, EM 4022/4222, GEN 2 (Samsys)
TAG DATA SIZE 64-BIT or 96-BIT (Samsys)
POWER ADJUST -4 dBm to +4 dBm (Samsys)
KILL CODE In the form: B3, B2, B1, B0
ACCESS CODE In the form: B3, B2, B1, B0
LOCK CODE 2 Character Hex Value (Alien)
LOCK AFTER WRITE ENABLED or DISABLED
RETRY ATTEMPTS 0 – 9
AUTO DETECT TAG Moves the label to find the tag and sets the present
distance. This will write to the tag in order to verify.
COMMUNICATIONS / HOST SETTINGS
OPTION FEEDBACK DISABLED, SCANNER, RFID HEX, RFID ASCII