davebell RL250S Manuale utente

0
Automatic Self-leveling Rotary Laser RL250S
User Manual

1
Maintenance and Safety
•While the instrument is operating, be careful not to expose your eyes to the laser beam. Direct xposure to a
laser beam for a long time may be hazardous to your eyes. The laser beam is equivalent to a class II (and
class 3R for HV Green Beam).
•Operate this laser so that the laser beam plane avoids impact on the eyes of vehicle drivers or pedestrians.
•Do not try to dismantle the instrument. Have it repaired by your dealer or supplier. Dismantling yourself may
worsen the problem or void your warranty.
•When attaching the instrument to a tripod, make sure the instrument is securely fixed. The tripod leg clamps
should be securely fastened. If not securely fastened or tightened, the main unit could fall off or the tripod
could fall over.
•The laser should not be stored or used in extreme temperature or during rapid temperature change. The laser
may not function properly if used out of the ambient temperature range.
•Store inside the carry case and place in a dry area not subject to vibration, dust or high moisture.
•If the storage temperature and ambient temperature for usage vary significantly, leave the laser in its case
until it can adjust to the ambient temperature.
•The laser should be transported or carried carefully to avoid impact or vibration.
•
The laser should be stored in the carry case and packed with cushioning material. Always handle the laser
with care.

2
1.What is included with your RL250S
•

3
Your RL250S includes the following parts:-
Main Instrument
Detector and Bracket
Remote Control
Charger
Target
Glasses
Hard Case with Foam Insert
Extra Alkaline Battery Pack c/w 4xAA Alkaline batteries .
Wall Mount Bracket
Please contact your supplier if any of the above parts are missing.

4
2.
Handle
Optical Glass
Light House
Control
Panel
Base
Rotating Head
Plug Hole
Plumb Up Beam
Plumb Down Beam
Find your way around the
RL250S

5
2.1 Control Panel
Switch ON/OFF
Left Spin
Right Spin
Direction Scan
Arrow Area
Manual/Auto
H.I Alert
Head Speed

6
2.2 Utilities of Panel
(1) Switch ON/OFF: Powers the laser up or down.
(2) Power indicator: When the light is on, the instrument is on.
(3)Manual/Automatic: The laser will initially enter into self leveling mode after be powered on. Press “Manual/Auto” for
once, the device enter into manual mode, in the meanwhile the slope of Y-axis can be adjusted by up and down arrows on
keypad panel, while press “Manual/Auto” again, the slope on X-axis can be set up by two arrows on panel. In these
period ,the other functions such as scanning, left spin or right spin are also available but without accuracy. When press
“Manual/Auto” the third time, the laser will get back to Auto-level mode and will self leveling again.
(4) Manual/Auto indicator: When Y indicator lights, the slope of Y axis can be adjust, when X indicator turns on, the
X-axis slope can be adjusted.
(5)Head speed: To change the speed of the rotating beam, press the [Hare/Tortoise Button]. Speeds of 0rpm, 60rpm
300rpm & 600rpm(Max.) can be obtained.
(6) Tilt/H.I alert: Enabling this mode warns the user if the laser level has been jolted.

7
(7) Tilt indicator: When the light is blinking slowly, the laser is in H.I alert mode. When the light is blinking quickly, the
laser level will not level as it has been jolted.
(8) Directional scanning: Circling knob. Angle of scanning includes 5 levels: 0-10°-45° -90°-180° H1 is without this
function.
(9) Left-spinning: Allows the laser beam to step/move counter-clockwise, only when the unit is in 0 RPM or scan mode.
H1 is without this function.
(10) Right-spinning: Allows the laser beam to step/move clockwise, only when the unit is in 0 RPM or scan mode. H1 is
without this function.
(11) Arrows: Adjust the slope for both axis by working together with Manual/Automatic button.

8
3. Directions:
3.1 Battery Installation
Rechargeable and alkaline battery packs are suitable for use to power this laser. To install:
1. Un-screw the bolt at the bottom of base part. Take off the battery pack. The laser is officially c/w a Ni-Mh battery pack.
2. Either to put the alkaline battery pack into the port or Ni-Mh battery pack according to the right electrode.
3. Re-screw the bolt at the bottom of base part.
4. H1 comes without Ni-Mh battery pack.
3.2 Instrument Placement
3.2.1 Horizontal scanning
Place the instrument on a tripod or stable flat surface, or hang it on a wall. Set the unit upright, and keep the slope of the
instrument within the range of -5 to +5 self-leveling range.
3.2.2 Vertical scanning
Place the instrument on the flat surface, and keep the slope of instrument within the range from -5
°
to +5, H1 is without
this function.

9
3.3 Operations
3.3.1 Power
Press the ON/OFF key to switch the laser on. If the power indicator light blinks, the voltage of the batteries is low and
batteries need to be replaced or recharged.
3.3.2 Leveling
When you turn the laser on, it will automatically level. The leveling process is indicated by a blinking laser beam. After
the laser has automatically leveled, the laser rotating head will rotate at the speed of 600 RPM.
If the instrument is placed improperly, or the slope of instrument exceeds the range of -5 to +5, the mode indicator and the
laser beam will blink at the same time.
Note: The instrument will shut down automatically if the unit exceeds the self-leveling system range for
more then 5 minutes.
3.3.3 Spinning
(1) Continuous spinning
Press the Key “Rotational speed adjustment” to control the spinning speed of the laser module. If press the key repeatedly,
the spinning speed of the laser module will continuously change as follows: 0-60-300-600-0 r.p.m.